3. Check all surfaces — the top, bottom and sides of the nShield Connect — for signs of
physical damage.
4. Check that there are no signs of physical damage to the vents, including attempts to
insert objects into the vents.
Front vent (to the right of the front panel controls):
Rear vent (to the right of the power supplies):
8.4.1.4. Disabling tamper detection and response functionality
Tamper detection and response functionality can be disabled if the customer's security
policy does not require it. The tamper detection and response functionality provides a
critical part of the defence in depth physical security strategy of the nShield Connect.
We do not recommend disabling tamper detection functionality.
To disable tamper responsiveness on your nShield Connect:
1. From the main menu select System > System configuration > Tamper config.
You are shown the following dialog:
Tamper responsiveness
is currently enabled.
This matches nCipher's
recommendation.
Do you want to disable
tamper responsiveness?