Taramps TW 30 G4 Manual

Taramps TW 30 G4 Manual

Automotive alarm

Advertisement

Quick Links

TW30
Wireless communication
with theAlarm Center
MANUAL
AUTOMOTIVE ALARM

Advertisement

Table of Contents
loading

Summary of Contents for Taramps TW 30 G4

  • Page 1 TW30 Wireless communication with theAlarm Center MANUAL AUTOMOTIVE ALARM...
  • Page 2: Before Starting

    This product is intended to make it difficult or inhibit the theft / robbery of the vehicle, or objects in • its interior. Before contacting TARAMPS technical support, read this manual, it contains all the necessary • information for the installation and use of the product.
  • Page 3: Remote Controls

    Controls Functions (Manufactured from June 2019) - Anti Jammer function. EXCLUSIVE IN THE G4 TARAMPS LINE. Jammer is when there is another control transmitting near the alarm center,making it impossible to turn the alarm on or off by the registered control.
  • Page 4: Remote Control Functions

    5) Remote Control Functions: FUNCTION CONTROL ACTION ALARM RESPONSE 1 Flash on Turn Signals+ 1 Siren beep3 1 - Turn alarm on Press Beeps indicate Open Door Item 9.1 2 flashes on turn signals + 2 siren beeps Note: 4 flashes on the turn signals+ 4 beeps, 2 - Turn Alarm off...
  • Page 5 6) Programming by Master Key Configure Select Function With the door open, turn the ignition on and hold the START master pressed until the desired function beeps. The alarm will beep with the current setting, to change, press Example: DOOR OPEN the master the number of times of the desired setting.
  • Page 6 7) Blocking by Presence Function / Remoteness Operation: With the ignition on and the doors closed, pulling the TR2-P control away from the vehicle automatically activates the distance lock. After the programmed time (Beep 9 of the configuration by the master), the ultrasound LED starts flashing ,the audio is turned off, the siren and turning signals will go off, after 10 seconds the engine will start failing until it is definitively blocked.
  • Page 7 7.1)Test Presence Function Operation: It is not necessary to move the control away from the vehicle, to test the lock, simply disable the automatic transmission of the TR2-P control, turn the ignition on , close the doors and wait. Disable Presence Function on the control - Hold the Power and Auxiliary keys pressed;...
  • Page 8 8) Lock by Secret Button - required to be enabled by master. OPERATION: With the ignition on and the doors closed, press the master key for 1 second. Otherwise, Secret Button Lock will be enabled. After the programmed time, (according to the Beep 9 setting), the ultrasound LED starts flashing, the audiowill be shut off, the siren and turning signalswill go off, after other20 seconds, the engine will begin failing until it is definitively blocked.
  • Page 9: Alarm Functions

    9) Alarm Functions: 1 DOOR OPEN WARNING: When turning the alarm on, if there are 3 BEEPs, it indicates that there is an open door. Close it and turn the alarm back on. If it is not solved the alarm will cancel the door monitoring. The rest will work normally.
  • Page 10 Installation Scheme: Fix on the vehicle windshield, 10cm below the roof Left Side Receiver Right Side Transmitter ATTENTION: The TW30 G4 LINE has a new Ultrasound transmitter. In case the old alarm central is replaced by G4, the transmitter sensor (right side sensor, without LED) must also be replaced by the new one.
  • Page 11: Relay Connections

    10) Relay Connections The lock, unlock, auxiliary and audio equipment outputs handle a maximum of 200mA. If you need to install equipment with a consumption higher than 200mA, relays must be used. Transform NEGATIVE alarm signal T r a n s f o r m P O S I T I V E s i g n a l Transform NEGATIVE signal (200mA) (200mA) into POSITIVE +12V ( A U D I O ) ( 2 0 0 m A )
  • Page 12 Window Activation Settings (continued) Set up Signal for Window/Electric Lock activation - With the door open, turn the ignition on. Configure - Hold the master pressed until beep 11. Select the Beep 11 function - The alarm will respond informing: START 1 Beep = Universal 2 Beeps = VW G5...
  • Page 13: Led Functions

    12) G2 Ultrasound Sensors New Transmitter* Fix the sensors to the vehicle's windshield, 10cm below the roof. (See page 10) Ultrasound Sensors come with digital sensitivity adjustment.Only change the default setting if necessary. Table Follows below: Sensor Sensitivity Click Alarm Response 1 Time +20% 1 Beep...
  • Page 14 13) Set up Auxiliary Output 2 - brown wire Programming by Master - With the door open, turn the ignition on. Configure - Hold the master pressed until beep 13. Select the Beep 13 function - The alarm responds by informing the current START setting: Door...
  • Page 15 13.2) Auxiliary Output 2 Setup- brown wire Programming by Master - With the door open, turn the ignition on. Configurar -Hold the master pressed until beep 13. Selecionar a função Beep 13 - The alarm responds which the current setting is : START 1 Beep = Reads Negative switch 1X = Porta...
  • Page 16 Activate Auxiliary outputs 2 and 3 + than 3 - Press and hold the OFF key on the control with the seconds ignition off and the alarm off. Auxiliary Output 3 - black/yellow wire (200mA positive) - continued 1) Auxiliary Output 3 - PULSE - Positive signal +12V. Output activated WITH auxiliary output 2.
  • Page 17 15) Open and Close Automated Gate - exclusive to TW30 G4 Programming: Clone - With the door open, turn the ignition on. Selecionar a função Beep 15 - Hold the master pressed until beep 15. START When releasing the master, the siren will sound a long beep.
  • Page 18 24 months from the date of purchase. In the event of a defect within the warranty period, TARAMPS' liability is limited to repairing or replacing the device manufactured by it.
  • Page 19 Fabricado por / Manufactured by: TARAMPS ELECTRONICS LTDA CNPJ / TAX ID: 11.273.485/0001-03 R. João Silvério, 121• Res. Manoel Martins Alfredo Marcondes - SP Indústria Brasileira - Made in Brazil...

Table of Contents