CHAPTER 1- SUMMARY OF USER'S COMMANDS ................................ 3
CHAPTER 2 - ABOUT THE KEYPAD .......................................................... 4
F
O
1. Setting/Changing and Deleting User's Code ................................... 7
2. Setting Date and Time ......................................................................... 9
3. Displaying System Date and Time..................................................... 9
4. Setting Follow-me Number ................................................................. 9
5. Quick Arming ...................................................................................... 10
6. Code Arming ....................................................................................... 10
7. Bell Squawk on Arming ..................................................................... 10
8. Disarming ............................................................................................ 10
9. On/Off Audible kiss-off ........................................................................11
10. Duress Disarming .............................................................................11
11. Cutting off Sounder and Stop Auto-dialing ....................................11
12. Bypassing/ Un-bypassing a Zone .................................................. 12
13. Escape Key [ESC] ........................................................................... 12
14. Emergency Keys .............................................................................. 12
15. Entry and Exit Delays ...................................................................... 13
16. 24-Hour Zone ................................................................................... 13
17. Trouble Display ................................................................................. 13
18. Zone Features .................................................................................. 14
19. Get Events from Event Logger ....................................................... 14
20. On/Off Door Chime .......................................................................... 15
CHAPTER 3 - INSTALLATION .................................................................... 16
...................................................................................... 16
............................................................................................. 17
RP208CN User's and Installer's Manual
INDEX
) ................................................................................ 4
.................................................................................. 5
.................................................................................. 7
............................................................... 16
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RP208CN and is the answer not in the manual?

Questions and answers

Summary of Contents for Roiscok RP208CN

  • Page 1: Table Of Contents

    19. Get Events from Event Logger ............14 20. On/Off Door Chime ................15 CHAPTER 3 - INSTALLATION ..............16 ..................16 EFORE NSTALLATION FAQ..............16 NSTALLATION AND OLUTION ..................... 17 OARD RP208CN User’s and Installer’s Manual Page 1...
  • Page 2 ROTOCOLS OCATION DEFAULT 31 ..............43 :L ERIODIC OCATION 32-94 ........43 :L OMMUNICATOR EPORTING ODES OCATIONS REPORTING CODES FOR ALARM EVENTS: ......... 43 RP208CN CONTROL PANEL CONTACT ID REPORTING CODES ..47 RP208CN User’s and Installer’s Manual Page 2...
  • Page 3: Chapter 1- Summary Of User's Commands

    The Backup Battery Power is low. AC Power AC Power is lost. Trouble Table No Clock Clock have not been set No Communication The Communication is in trouble. No Siren The Siren connection is in trouble. RP208CN User’s and Installer’s Manual Page 3...
  • Page 4: Chapter 2 - About The Keypad

    CHAPTER 2 – ABOUT THE KEYPAD RP208KCL (LCD Keypad) The RP208CN can support LCD Keypad. Each control panel can work with four LCD Keypads at most. Each keypad in your system reports its status by its LED (lighted) indicators and LCD display.
  • Page 5: Led Indication And Keys

    The LCD Display on RP208KCL indicate the status of each of the system, including zones Triggered, Armed/Disarmed system, Trouble, Time and other programming information. If there is only “ROISCOK” on the display, which means all the zones are not triggered. When Z1, Z2, Z3, Z4, Z5, Z6, Z7 or Z8...
  • Page 6 (e.g. door and windows), while leaving interior detectors (e.g. motion detectors) disarmed (bypassed). When [STAY] key is depressed, the interior zones will not be armed. 10. Exit/Delete [ESC] Key [ESC] is suitable for correction system operation RP208CN User’s and Installer’s Manual Page 6...
  • Page 7: Unction And Peration

    RP208CN can set 10 of Codes, one is Master Code and another 9 are User’s Codes. To change the Master Code, and /or to set up User Coeds, follow the steps.
  • Page 8 Master Code (although it can be changed). Step Operation The system must be disarmed. Enter the User Functions Mode [*] and choose Codes [5], Press [*][5] Enter the current 4-digit Master Code: [5 ][ 6][7 ][8 ] RP208CN User’s and Installer’s Manual Page 8...
  • Page 9: Setting Date And Time

    Make sure the numbers are all correct; then enter [#]. Operate as: Set Follow-Me Phone NO.1: [*]+[7]+[1]+[MASTER CODE]+Phone NO.1+[#] Set Follow-Me Phone NO.2: [*]+[7]+[2]+[MASTER CODE]+Phone NO.2+[#] Set Follow-Me Phone NO.3: [*]+[7]+[2]+[MASTER CODE]+Phone NO.3+[#] Set Follow-Me Phone NO.4: [*]+[7]+[2]+[MASTER CODE]+Phone NO.4+[#] RP208CN User’s and Installer’s Manual Page 9...
  • Page 10: Quick Arming

    It’s defaulted as quick arm. If the user requires code arm, it should be set when programming in advance. When RP208CN is set as code arm, it can not support [ARM] and [STAY] for quick arming. And it should be operated as: [ARM] + [Master Code], or [STAY] + [Master Code] to arm or stay arm.
  • Page 11: On/Off Audible Kiss-Off

    11. Cutting off Sounder and Stop Auto-dialing If outside premises, open an entry door; the keypad(s) will beep indicating that the Entry Delay period has begun. The entry delay is defaulted as 30 seconds. RP208CN User’s and Installer’s Manual Page 11...
  • Page 12: Bypassing/ Un-Bypassing A Zone

    When disarming, all the bypassed zones will be automatically un-bypassed. There are two methods of Bypassing: Quick Bypassing: It’s defaulted that all the zones of RP208CN can be set as Quick Bypass. Bypass a zone, simply press the corresponding key for or above 2 seconds.
  • Page 13: Entry And Exit Delays

    11-13 of Chapter 5. 16. 24-Hour Zone RP208CN can support several kinds of zones. All other forms of protection, including fire and 24-hour panic alarms (I.e. police, fire, and medical) are always ready to report alarms and do not need to be armed.
  • Page 14: Zone Features

    18. Zone Features RP208CN has 8 programmable zones. Each zone can be programmed as Entry/Exit Delay Zone, Instant (Intrusion) Zone, Panic Zone, Fire Zone, Tamper Zone, Remote Zone etc . Entry/Exit Delay Zone: A delay period was chosen during your system’s installation to provide suitable time to allow for your entry and exit.
  • Page 15: On/Off Door Chime

    When alarm occurs during armed system only the external sounder will be activated. Enter [*]+[8]+[Master Code]+[2] to turn on/ off the door chime. RP208CN User’s and Installer’s Manual Page 15...
  • Page 16: Chapter 3 - Installation

    Consecutive Output. With Easier Programming and More Elegant Shape, Everywhere Shows the Products’ Luxury. The RP208CN are intended to address the needs of many homes, offices, and small businesses. Its operation is designed around microprocessor and EEPROM (Electrically Erasable Programmable...
  • Page 17: The Main Board

    7-eligible label and production serial number 8- “AUX” safety for assistant power, 0.5A 9― “BELL” safety for siren power, 1A 10-“BAT” safety for standby power, 2A 11-“BAT-” the cathode of the standby power RP208CN User’s and Installer’s Manual Page 17...
  • Page 18 34-“YRL” the port should connect to the yellow line on the keypad. 35-“BLK” the port should connect to the black line on the keypad. 36-“RED” the port should connect to the red line on the keypad. RP208CN User’s and Installer’s Manual Page 18...
  • Page 19 Fig.2 RP208MB RP208CN User’s and Installer’s Manual Page 19...
  • Page 20 Fig.3 Connection Instruction RP208CN User’s and Installer’s Manual Page 20...
  • Page 21: Install Control Panel And Keypad

    Install Control Panel and Keypad The RP208CN control panel should install in the aridity, near by AC power supply which can't be power off and connect the ground well and be easy to connect the phone line. Use correct tool, avoiding the damage toward the equipments.
  • Page 22: Connect Detector(S)

    As Fig.4, connecting voice module just need to insert it into the connector on the control panel. 1(record)-recording button 2(play)-test record button 3 - the eligible label including production serial number, tester number, production type and version number. 4-recording microphone RP208CN User’s and Installer’s Manual Page 22...
  • Page 23: Connect Wireless Module

    Zone-1 Indicating Light Set Aside Zone-2 Indicating Light Remote Armed Zone-3 Indicating Light Set Aside Zone-4 Indicating Light Trouble Output Receive Data Indicating Light Zone 1 Connector Interfered Zone 2 Connector Setting Indicating Light RP208CN User’s and Installer’s Manual Page 23...
  • Page 24: Please Refer To Rp208Ew4 User's Manual For More Details

    3. When using remote controller, the port 3 should connect switch lock zone of RP208CN 4. In normal, the dial 1 and 2 on the dial switch 10 should be set at the position Please refer to RP208EW4 User's Manual for more details. RP208CN User’s and Installer’s Manual Page 24...
  • Page 25 Fig.6 The Wireless Receiver RP208CN User’s and Installer’s Manual Page 25...
  • Page 26: Chapter 4 - Function And Technical Data

    CHAPTER 4 - FUNCTION AND TECHNICAL DATA You can communicate your RP208CN (8 zones control pane) through LCD Keypads (RP208KCL). Each RP208CN can match with 4 LCD keypads at most. With the LCD Keypad(s), you can operate your system by arm/disarm, bypass, emergency, closing the siren, inspecting trouble, programming the system and so on.
  • Page 27: Main Features Of Rp208Mb

     1 Master Code, this Code Can Create Duress Code Automatically  9 User Codes, Each Code Can Create Duress Code Automatically Periodic Test  Offer Testing Report to Alarm Center Automatically Every Day Peripheral Equipment RP208CN User’s and Installer’s Manual Page 27...
  • Page 28 22 in Chapter 5 for details) Charging of Standby Battery  Main Board attaches charging circuit, the Standby Battery can be charged via BAT port TECHNICAL DATA Main Board Input power 16.5VAC 25VA via transformer RP208CN User’s and Installer’s Manual Page 28...
  • Page 29 Fuse BELL Bell/LS Power 1A Fuse BAT Battery Power 2A Dimension/weight 80*167mm/0.17kg Keypads LCD Keypad Current consumption 90mA typical, 130mA max Control panel connections 4-wire up to 1000M from panel Dimensions 110*130*25mm Weight 0.23kg RP208CN User’s and Installer’s Manual Page 29...
  • Page 30: Restoring Factory Defaults

    Programming is a process of altering or setting the location data of the control panel, RP208CN has 94 locations 01-94 for setting data, and each data will correspond to a different function of the control panel. The location are made up of 2 digital, the data of location are made up of 1 digital, 2 digital or many digital.
  • Page 31: Entry/Exit Program

    (error) beep will sound after pressing [#] Check the data stored The data display [5678] in Location"08" on the LCD RP208CN User’s and Installer’s Manual Page 31...
  • Page 32: General System Parameters: Locations 00-07

    Default: 0000 PURPOSE: to assign the system's Central Station Account Number. Hexadecimal account numbers (those using 0 through 9 and A through F) are accepted by RP208CN. Use the key combinations below to enter hexadecimal digits "A" through "F" Hex digit...
  • Page 33: Installer Code : Location 08-10

    3 digits, 1 second at least, 255 second at most. For example, 030 means the delay time is 30 seconds. When arm, it won’t alarm to leave the RP208CN User’s and Installer’s Manual Page 33...
  • Page 34: Intrusion Zone Types And Zone Sounds :Locations 14-21

    If the system is armed to AWAY (ARM) mode: this type of zone behaves like the Entry Follower, described above If the system is armed to the STAY mode: this type of zone will be bypassed. RP208CN User’s and Installer’s Manual Page 34...
  • Page 35 Fire LED. Tamper Zone If violation, will cause an immediate tamper alarm, regardless of the system's armed/disarmed state. Suggest Zone 6 on RP208CN to be a Tamper Zone. Panic Zone If violated an immediate panic alarm will be announced , regardless of the system's armed /disarmed state.
  • Page 36: Utility Outputs - Event And Result :Locations 22, Default 00

    Urgency zone alarm doesn’t result the siren sound but calling to the CMS or follow-me numbers. Zone 6 on the RP208CN is reserved as a Tamper Zone. This zone can be programmed to any zone type. If the zone was programmed as Tamper, in violation, a Tamper Code report will be sent and the Tamper LED on the keypad will light up.
  • Page 37 Fire Keying Follow (Pulse) UO is activated when a Fire alarm is triggered by violation of zone 5, defined as Fire, 0r by pressing the keypad's [4] and [5] RP208CN User’s and Installer’s Manual Page 37...
  • Page 38 Zone 4 Alarm Follow(Latched) Zone 4 Alarm Follow(Pulse) Zone 5 Alarm Follow(Latched) Zone 5 Alarm Follow(Pulse) Zone 6 Alarm Follow(Latched) Zone 6 Alarm Follow(Pulse) Zone 7 Alarm Follow(Latched) Zone 7 Alarm Follow(Pulse) Zone 8 Alarm Follow(Latched) RP208CN User’s and Installer’s Manual Page 38...
  • Page 39: Communication Parameters:locations26-29

    Zone 8 Alarm Follow(Pulse) Communication Parameters:Locations26-29 Locations 26 and 27 allow you to define the manner in which the RP208CN communicates with the Central Station when it reports alarms, Restores, troubles, openings/closings, and tests. Digital Communicator Controls:Locations 26, Default 41 ...
  • Page 40 20 pulses/sec 650ms 1900Hz 10 pulses/sec 650ms 1900Hz (PPS) Kiss off/ Inter Digit Code Format Name Validation pulses/sec Handshake Time Format Silent Dual Knight/ADEMCO 1400Hz round Slow Silent Dual Knight/ADEMCO 1400Hz round Slow Extended RP208CN User’s and Installer’s Manual Page 40...
  • Page 41: Cs Protocols : Location 28, Default : 03

    When selecting 03 (the Pulsed Protocol) the default for all the reported codes will be "00"and any other code should be entered manually follow the CMS software. Digit Format Name Inter-digit Time Date Frequency Contact ID 03(default) Location: 29 Preparation System Controls:Location 30, Default 13 RP208CN User’s and Installer’s Manual Page 41...
  • Page 42  Second digit: determine the number (or letter)corresponding to the use of silent Panic/Bell Squawk on Arming /3 Minute Bypass Location:30 System Controls: (1 Digig) Quick Digig Loudspeaker/Bell-Siren Quick Bypass Bell-Siren 1(default) Bell-Siren RP208CN User’s and Installer’s Manual Page 42...
  • Page 43: Periodic Test Time :Location 31

    Enabled 3(default) Enabled Disabled Periodic Test Time:Location 31 If desired, the RP208CN can send a daily test transmission to the Central Station to Verify the operation of the Unit's Digital Communicator. Location:31 Periodic Test Time Default: 0000 Sets a fixed, daily time for sending an test transmission to the Central Station.
  • Page 44 Zone 8 Restore code Keypad Fire Restore code Keypad Panic Restore Code Keypad Special Emergency Restore Code User 0 arm (the "Master" Code, "Quick Arm" OR "Keyswitch" Arm)0 User 1 arm Reporting code RP208CN User’s and Installer’s Manual Page 44...
  • Page 45 Bell Loop Restored Reporting Code Zone 1 Bypass / Restore Reporting ABCD code Zone 2 Bypass / Restore Reporting ABCD code Zone 3 Bypass / Restore Reporting ABCD code Zone 4 Bypass / Restore Reporting ABCD code RP208CN User’s and Installer’s Manual Page 45...
  • Page 46 Zone 5 Bypass / Restore Reporting ABCD code Zone 6 Bypass / Restore Reporting ABCD code Zone 7 Bypass / Restore Reporting ABCD code Zone 8 Bypass / Restore Reporting ABCD code RP208CN User’s and Installer’s Manual Page 46...
  • Page 47: Rp208Cn Control Panel Contact Id Reporting Codes

    RP208CN Control Panel Contact ID reporting codes Event reporting Contact ID Zone alarm/unarm Report code Entry/exit alarm Entry/exit Restore Panic alarm Panic Restore 24 hours zone alarm 24 hours zone Restore Tamper zone alarm Tamper zone Restore Smoke induce zone alarm/Restore...
  • Page 48 AC Restore Battery power low Battery power Restore Warning sign fault Warning sign Restore Fire zone fault Fire zone Restore On/off reporting User arm User unarm User 0 quick arm/unarm Force arm periodic test RP208CN User’s and Installer’s Manual Page 48...
  • Page 49 Zone 7 Settings Zone 8 Settings Utility Output Dialer Controls CS Protocols 1 CS Protocols 2 System Controls Periodic Time Set Zone 1 Alarm Zone 2 Alarm Zone 3 Alarm Zone 4 Alarm RP208CN User’s and Installer’s Manual Page 49...
  • Page 50 User 8 disarm User 9 disarm Auto ARM Forced arm Stay Arm Duress Disarm Daily test Report Rpt Code Low Bat Rpt Code AC Loss Rpt Code Fire Tb Rpt Code Bell Loop RP208CN User’s and Installer’s Manual Page 50...
  • Page 51 Zone 2 Bypass / Restore Zone 3 Bypass / Restore Zone 4 Bypass / Restore Zone 5 Bypass / Restore Zone 6 Bypass / Restore Zone 7 Bypass / Restore Zone 8 Bypass / Restore Phone1 Phone2 RP208CN User’s and Installer’s Manual Page 51...