Thank you for choosing a product from Standby.

Technical Data

Description
Dimensions
Weight
Nominal voltage
Operating voltage
Limit voltage
Current consumption
Inputs
Outputs
Enclosure rating
Approvals
- Accoustic
- EMC
Included

Installation

The Control-Unit can be installed as desired in the vehicle interior. Due to the housing design, the
Control-Unit can be variably attached and connected to the vehicle with four screws. Care must be
taken to ensure good accessibility of the connectors.
AM150B
Units
44.6 mm x 136.1 mm x 131 mm
Approx. 400 g
12 / 24 VDC
10,8 to 14.4 VDC / 21.6 to 28.8 VDC
-32 to + 32 VDC
< 500μA at standby mode
7 x < 20mA, active high
1 x < 20mA, active low
2 x < 6A
4 x < 2A
IP 54
T046Lu (Swedish approval, only valid together with two KSR350 4Ω(12V)/16Ω(24V) )
ECE R10
1
Standby AB – standbygroup.se
MS350 - Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS350 and is the answer not in the manual?

Questions and answers

Summary of Contents for Standby MS350

  • Page 1 MS350 - Manual MS350 Thank you for choosing a product from Standby. Technical Data Description Units Dimensions 44.6 mm x 136.1 mm x 131 mm Weight Approx. 400 g Nominal voltage 12 / 24 VDC Operating voltage 10,8 to 14.4 VDC / 21.6 to 28.8 VDC...
  • Page 2 MS350 - Manual Connection Explanation of naming Example X = Input Y = Output S = Supply The first number in the name describes the connector number and the second number the pin number. + means active high, connect to positive supply to activate.
  • Page 3 Turn wheel to choose presets for selected country. Pos 0 CAN This position is used when the amplifier is connected to a CAN based control system from Standby. The connected control system sets the functionality of the amplifier. Please see the description for the control system regarding functionality and connection.
  • Page 4 MS350 - Manual Pos 1 Stand-alone functions Sweden Connector P1 Standby Function Imax Recommended fuse Name Beacon left Y11+ Beacon right Y12+ Power supply for outputs S13+ < 20A Common fuse max 15A (Y11+, Y12+, Y15+, Y16+, Y17+, Y18+) (see connection section)
  • Page 5 MS350 - Manual Pos 2 Stand-alone functions Norway Connector P1 Standby Function Imax Recommended fuse Name Beacon left Y11+ Beacon right Y12+ Power supply for outputs S13+ < 20A Common fuse max (Y11+, Y12+, Y15+, Y16+, Y17+, Y18+) 15A(see connection...
  • Page 6 MS350 - Manual Pos 3 Stand-alone functions Denmark Connector P1 Standby Function Imax Recommended fuse Name Beacon left Y11+ Beacon right Y12+ Power supply for outputs S13+ < 20A Common fuse max (Y11+, Y12+, Y15+, Y16+, Y17+, Y18+) 15A(see connection...
  • Page 7 MS350 - Manual Pos 4 Stand-alone functions Finland Connector P1 Standby Function Imax Recommended fuse Name Beacon left Y11+ Beacon right Y12+ Power supply for outputs S13+ < 20A Common fuse max 15 A (Y11+, Y12+, Y15+, Y16+, Y17+, Y18+)
  • Page 8 Standby will not be held liable for improper installation or use of this product. Please follow all instructions provided. Professional advice and proper installation of the Standby products by an authorized Standby Partner are recommended to provide maximum safety and function AM150B Standby AB –...

Table of Contents