Technical data boiling water storage heater:
• Connection:
• Installation elevation:
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative humidity:
• Ambient temperature:
• Standby power loss (switched on):
• Standby power loss (holiday mode):
• Standby power loss (switched off):
• Energy efficiency class:
Sanitary data:
• Boiling water storage heater capacity:
• Available storage heater volume at 100 °C:
• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
• Flow rate at 0.3 MPa flow pressure
- mixed water:
- boiling water:
• Boiling water temperature:
The actual temperature may differ slightly
due to different ambient pressures.
• Heating time from 10 °C to 100 °C:
• Clamping length of fitting:
• Water connection to storage heater:
• Water connection fitting:
Thermal disinfection of the fitting is possible.
Confirmation
Status
Initialisation
Heating phase
Ready for operation
Holiday mode, cooling-down
phase
Holiday mode
Defects
13
wall socket with earth wire,
protected via a 10 A fuse
max. 2000 m above sea level
230 V AC / 50 Hz
0.2–0.5 MPa
max. 0.8 MPa
approx. 6 l/min
approx. 3 l/min
M: approx. 20 min
max. 60 mm
cold/hot water from the service valve
boiling water from storage heater
Storage heater LED
white
red, flashing
red, continuous
orange, flashing
orange, continuous
agenta, flashing/continuous
Flush pipes thoroughly before and after installation
(observe EN 806)!
2200 W
Note: The volume of water in the storage heater will expand as
IP X4
it is heated. The expansion water must drip out of the funnel of
max. 95 %
the safety assembly.
0–40 °C
This is a necessary and completely normal process.
14 W
5 W
Check all connections for leakage.
1 W
Retighten screw connections as necessary.
A
4 l
approx. 3 l
Unlock the child lock to draw off boiling water, see A.
0.2 MPa
Drawing off cold or hot water, see B.
1.6 MPa
Activating holiday mode, see C.
Note:
In order to prevent incorrect operation and for protection against
injury, we recommend affixing the sticker provided.
100 °C
cold water
CAUTION!
Risk of damage!
Always disconnect from the voltage supply before
carrying out maintenance work on the system. The plug-in
connector can then be disconnected.
If work is performed on mains power supply or in case of
any maintenance work, the GROHE Red boiling system
must be bled as otherwise blasts of steam could form as a
result.
• Draw off boiling water from the storage heater until just cold water
flows.
• Close the service valve, switch off the storage heater and
disconnect the mains plug.
• Open the lever on the fitting and as well as the rotary knob on the
safety assembly to depressurise the storage heater.
• Drain the storage heater (not required each time maintenance is
performed): Remove the cap or hose to the mixing valve and
drain the storage heater using the connecting hose to the safety
assembly.
• Inspect and clean all parts, replace as necessary and lubricate
with special fitting grease.

Installation and commissioning

Operation

, see page 8.

Maintenance and cleaning