Page 1
Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of all types of weighing and measurement products since 1931.
Page 2
Operating Instructions Sartorius Combics CAPXS.. Models Stainless Steel Weighing Platforms for Use in Hazardous Areas/Locations 98648-010-95...
Contents Symbols Intended Use Warning and Safety Information Warranty Installation Instructions Installation Care and Maintenance Use of in Legal Metrology in the EU (or EEA) Declarations of Conformity Accessories Zertifikates The following symbols are used in these instructions: § indicates required steps $ indicates steps required only under certain conditions >...
Warning and Safety Information The weighing platform meets the system into operation. Furthermore, the Disconnect the platform from AC power requirements for Group II, Category 2 trained technician must have the required before connecting or disconnecting equipment in accordance with EC Directive qualifications and must be familiar with the cables.
Installation Instructions § Prepare a suitable place of installation for the weighing platform. The place of installation should be dry, level and even. The allowable operating temperature range is -10°C to +40° (14°F to 104°F). The permissible load that can be carried by the chosen working surface must be sufficient for both the weighing platform and any load placed on the platform.
Page 6
Conditions for Installation Before putting the equipment into operation, it is important to make sure that the cable of the power supply is correctly connected to the power outlet (mains supply). All equipment must be connected to the equipotential bonding conductor via grounding cable (not included in delivery) connected to the grounding terminals on each device.
Installation § Connect the cable of the weighing platform to a suitable indicator, such as the FCT01-X from Sartorius. Note: The cable gland on Sartorius indicators is installed at the factory. Please use extreme caution when performing any work on the equipment that affects this cable gland. §...
Page 8
Key to Model Codes (CAPX ab - cd - e): Product family Material Number of Capacity in kg Dimensions Resolution ..load cells see Table 2 see Table 1 see Table 2 CAPX.. Combics S = stainless steel 1 = one load cell Analog 4 = four load cells Platform...
Page 9
Operating Limits Do not place loads on the weighing platform that exceed its maximum weighing capacity. Depending on the position of the load (center, side, one-sided corner load), the maximum capacity of the weighing platform is as follows: Model Center Side Corner 4500...
Care and Maintenance Cleaning $ Unplug the weighing instrument from the AC power before cleaning. Remove dust from the weighing platform regularly (see EC type-examination certificate) $ If the weighing instrument is in a dry room, use a damp cloth to wipe down the weighing platform.
Declarations of Conformity Use of in Legal Metrology in the EU (or EEA) The weighing platform complies with the requirements of the The Weighing Platform as a Part of a Verifiable Weighing applicable Council Directives of the European Union: System The weighing platform is to be considered a modular device.
Accessories - Drive-on ramp, stainless steel, for platform sizes: - Roller-ball load plate, for platform sizes: PlatformRamp Size in mm Accessory no. size in mm width Accessory no. 400 x 300 YLP01CWS 800 x 600 YAR01CWS 500 x 400 YLP02CWS 1000 x 1000 1000 YAR02CWS...
Page 34
Sartorius AG Weender Landstraße 94-108 , Germany 37075 Göttingen +49/ Telefon 0551.308.0 +49/ 0551.308.3289 www.sartorius.com Copyright by Sartorius AG, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG.