1000 hour timer with prox wiring

Advertisement

Control Wiring
Control Wiring
1L1
FORWARD RUN POWER (SEE NOTE #5)
NOMINAL 115Vac/50/60Hz/1Ph
1TB-1
BK/18
1FU
1.5 A
SLO-BLO
BK/18
1TGS
ON-OFF
SWITCH
(15 AMP)
BK/18
1TR-11
BK/18
1TR
1
3
1TR-9
BK/18
1PB
BL/18
BL/18
1TR-10
WIRING DETAILS
RELAY CONTACTS AVAILABLE
1TR
1
4
WIRE COLOR ABBREVIATIONS:
BK = BLACK
PK = PINK
BL = BLUE
R = RED
BR = BROWN
V = VIOLET
GY = GRAY
WH = WHITE
GN = GREEN
Y = YELLOW
OR = ORANGE
TERMINAL LOCATION
1TB - FRONT PANEL
1TR - BEHIND FRONT PANEL
AVAILABLE TERMINALS
1TB - 7, 8
1TR - 4, 6, 7, 8, 9
Notes:
1. BK / 18 = Wire Color / AWG = Black /18 AWG
2. See page 3 for Field Wiring
3. Forward run condition power to be suppled only when conveyor is running in the forward condition. When con-
veyor is off or running in reverse, power must be removed.
4. 1 JPR from 1 TR-3 to 1 TR-6 is required for operation.
5. Set timer operating mode to Cu-c
2
CONTROL WIRING
INDICATES FIELD WIRING
MAIN POWER SWITCH
1TR
1PRS
R/18
BR
BL
1TB-5
1TB-6
GN/Y
1TB-3
GROUNDING
1L3
1TB-3
GN/18
ENCLOSURE
BACK PANEL
1L2
See Note 4
1TB-2
WH/18
1JPR
1TR-3
WH/18
1TR-2
R/18
1SOL
1TB-4
SN
1FU
BACK OF FRONT PANEL
1TR-6
LAYOUT
8
7
6
1TR
11 1 2
9
10
1TB
1
2 3
4
5
6 7 8
FRONT PANEL LAYOUT
BEHIND FRONT PANEL
1TR
ON
OFF
1PB
1TGS
GND SCREW
ENCLOSURE BACK PANEL LAYOUT
5
4
3
313302B