1. Product description
The transmodulators are designed for digital transmodulation with Transport Stream Processing. Modules processor
enables services filtering, remultiplexing, modifying SI (Service Information), generating NIT (Network Information table),
LCN (Local Channel Number), restamping PCR (Program Clock Reference). All of the configurations can be changed using
the Web Interface.
tdx4168
– transmodulator with 16 DVB-S/S2 input channels and 8 DVB-T/ISDB-T output channels (outputs are grouped
into 2 groups that consists of four neighbouring channels).
tdq4168
– transmodulator with 16 DVB-S/S2 input channels and 8 DVB-C/J.83B output channels (outputs are grouped
into 2 groups that consists of four neighbouring channels).
Transmodulator can be used as stand alone device or as part of the headend station.
The product is intended for indoor usage only.
2. Safety instructions
Installation of the transmodulator must be done according IEC60728-11 and national safety standards.
Any repairs must be made by skilled personnel.
Do not expose this transmodulator to moisture or splashing water and make sure no objects filled with liquids, such as
vases, are placed near or on the unit.
Avoid placing the transmodulator next to heat sources such as central heating components or in areas of high humidity.
Keep the transmodulator away from naked flames.
If the transmodulator has been kept in cold conditions for a long time, bringing it into a warm environment may cause
condensation, so allow it to warm up for no less than 2 hours before plugging into the mains.
Ventilation should not be impeded by covering the transmodulator, such as newspapers, table-cloths, curtains etc.
Mount the transmodulator in a vertical position only. If installing in a 19" rack system additional forced air cooling fans
may be required (see table "Technical specifications" - operating temperature range).
Always allow 10 cm of free space from the top, front and bottom of the unit to enable any heat to be dissipated.
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled
or discarded according to applicable local and national regulations.
Equipment intended for indoor usage only.
This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN IEC62368-1, RoHS norm EN50581.
This product is in accordance with Custom Union Technical Regulations: "Electromagnetic compatibility of technical
equipment" CU TR 020/2011, "On safety of low-voltage equipment" CU TR 004/2011.
This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.
Vers. 1.02
tdx4168, tdq4168
1
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the tdx4168 and is the answer not in the manual?

Questions and answers

Summary of Contents for Terra tdx4168

  • Page 1 16 DVB-S/S2 to 8 DVB-T / ISDB-T / DVB-C / J.83B transmodulators tdx4168, tdq4168 1. Product description The transmodulators are designed for digital transmodulation with Transport Stream Processing. Modules processor enables services filtering, remultiplexing, modifying SI (Service Information), generating NIT (Network Information table), LCN (Local Channel Number), restamping PCR (Program Clock Reference).
  • Page 2: External View

    3. External view DC OUT 13/18V DC OUT 13/18V DC OUT 13/18V 1A max 1A max 1A max tdx4168 tdx4168 ETHERNET RESET TERRA - - + + - - + + DC IN 12V DC IN 12V 1 - ◄ - RF input of SAT IF signal, DC output for LNB.
  • Page 3: Installation Instructions

    4. Installation instructions Read the safety instruction first. All settings can be changed using the web browser via control Ethernet interface. Disconnect power supply unit from the mains before making any changes in the connections of the module. Fasten the module on DIN RAIL or individual holder.
  • Page 4: Mounting On Din Rail

    Mounting on DIN rail Figure 3. Mounting to DIN rail Figure 4. Mounting from DIN rail tdx4168 tdx4168 tdx4168 ETHERNET ETHERNET ETHERNET RESET RESET RESET TERRA TERRA TERRA - - + + - - + + - - + +...
  • Page 5 6. Operating 6.1 Initial configuration All modules leave the factory with this control over Ethernet interface IP address: 192.168.1.10. In order to avoid conflicts with other IP addresses, it is necessary to perform an initial configuration in the local mode. Subsequently, it will be possible to access the module via local area network (LAN), either to change the configuration or to check the operating status.
  • Page 6: System Status Table

    Device information table This shows the following data of module: “Device model”: model of the module. “Serial number”: serial number of the module. “Software version”: module software version number. “System time”: current time, synchronized from the TDT table of the input stream or NTP server. Local time offset can be selected in the "IP settings"...
  • Page 7 “Universal LNB” - power supply voltage of the converter is chosen according to the selected polarization – 18 V Horizontal, 13 V Vertical; the 22 kHz is set depending on given "LNB HI frequency" "LNB LO frequency" and “Input frequency” parameters. For example: LNB Hi=10,600, LNB Lo=9750, then F=(950+10,600+2150+9750)/2=11,725 MHz.
  • Page 8 Figure 14. Demodulator status table The following information is displayed in the table “Demodulator status”: “RF level” - RF signal level at the module input. Level indication - approximate. The values of the following parameters are displayed only if the module has synchronized with the input signal. “Modulation standard”...
  • Page 9 A list of services in the selected channel will appear. „List of services“ table shows a list of available services. Icon before the service name indicates service type. Bitrate of each service is measured in real time. Services that currently are not running will be displayed as grayed.
  • Page 10 Service type Description 0x00 reserved for future use 0x01 digital television service (see note 1) 0x02 digital radio sound service (see note 2) 0x03 Teletext service 0x04 NVOD reference service (see note 1) 0x05 NVOD time-shifted service (see note 1) 0x06 mosaic service 0x07...
  • Page 11 SSDP packets (239.255.255.250:1900 and 239.255.255.246:7900). Also make sure that all modules are connected to the same Ethernet network. NOTE: If in the RF network exists transponders that is generated by old TERRA transmodulators/modulators, the frequencies and modulation parameters must be filled manually (Figure 20).
  • Page 12 6.6. TS info This tab Lists all outgoing servises. You can easily filter out needed output channels by selecting needed output in table "TS Info". This lets you quickly view and setup LCN for every channel also check your Output bitrate and ensure that it is not overflowing.
  • Page 13 6.7. RF outputs Transmodulators tdx4168, tdq4168 have two independent groups of four adjacent channels. Figure 22. DVB-T output parameters (tdx4168) "Output frequency“ parameter can be entered manually or selected as a channel from combobox. Channels that can be selected from the list depend on which region is selected. If you need any other frequency – select “Manual” and type the needed frequency.
  • Page 14: Snmp Settings

    6.8. SNMP settings Figure 24 "SNMP settings" table is located in “IP parameters” tab. The description of the SNMP configuration parameters: "Read Community" - community name acts as a password that is shared by multiple SNMP agents and one or more SNMP managers. "Read Community"...
  • Page 15 6.11 System menu This menu tab contains following submenu items: “Event logs”, “Export parameters”, “Import parameters”, “Firmware upgrade”, “User management”, “Restore defaults“, “Restart the device“, “Auto Restart“, “Time, Date”, “Language”. Mouse over to show the list of this submenu. 6.11.1 Event logs Various important events, errors, warnings will be logged into the system, see Figure 27 "Event logs".
  • Page 16: User Management

    Figure 29. Firmware upgrade 6.11.5 User management User may change a password here. Length of the password is up to 16 symbols. Type current password and double enter new password to change it. If logged in user has admin role, new users can be added (see Figure 30 "User management"). Figure 30.
  • Page 17: Auto Restart

    6.11.8. Auto Restart Enable "Auto restart" to schedule periodical restart. Fill in "Scheduled restart time" to restart device on the particular time. The restart will occure every day on speciefied time. 6.11.9. Date, Time System time can be configured manually or taken from NTP server (only if module can access NTP server). Also there is an option to select the time source from TS as shown in the Figure 31.
  • Page 18: Technical Specifications

    8. Technical specifications Type tdx4168 tdq4168 Sections input/output 16/8 RF input frequency range 950-2150 MHz LNB powering/control 0/13/18 V & 22 kHz, 1 A total, DiSEqC 1.0, EN50607, EN50494 level / impedance 55-95 dBµV / 75 W modulation QPSK, 8PSK (DVB-S/S2) 2 ÷...