The Druid LCD 20 can also be connected to an electric fence in conjunction with an electric
fence energizer for added security. Ensure that the output energy of the electric fence
energizer is 8 joule or less to prevent damage to the Druid LCD 20. Always consult the
installation manual of the energizer before installation.
Live wire connection
Earth wire connection with earth loop monitoring (preferred)
The fence earth wire is
to be connected to the
main earth spike and
not directly to the unit.
Install the main earth spikes close to the unit
Earth wire connection with no earth loop monitoring
The fence earth wire is
to be connected to the
main earth spike and
not directly to the unit.
Note: Diagrams illustrate connections of only 1 zone for simplicity. Both zones can be wired as shown.
Energizer
Energizer
All earth spikes are connected to one wire of the fence
only, and this one wire is connected to the rest of the
fence at the main earth spikes.
Energizer
Install the main earth spikes close to the unit
Fence wiring diagrams
Druid LCD 20
Druid LCD 20
Druid LCD 20