Dry contact sensor

Advertisement

Quick Links

Dry Contact
Sensor
Installation Guide
ADC-S40-DC

Advertisement

loading
Need help?

Need help?

Do you have a question about the ADC-S40-DC and is the answer not in the manual?

Questions and answers

Summary of Contents for Alarm.Com ADC-S40-DC

  • Page 1 Dry Contact Sensor Installation Guide ADC-S40-DC...
  • Page 2 In the box • ADC-S40-DC • Installation guide Dry Contact Sensor • Screw (x2) • Mounting bracket • Cable tie • CR123 battery • Double-sided tape ❶ ❷ Dry Contact Sensor Mounting bracket ❶ ❷ Network LED Alert LED...
  • Page 3: Switch Definitions

    Switch Definitions Wiring diagrams Monitoring the R-wire with float switches NO: Connected to a Normally Opened Circuit wired between the HVAC control board and the thermostat NC: Connected to a Normally Closed Circuit 24V: Connected to a 24V Circuit : Connected to a non-powered circuit.
  • Page 4 ❸ Monitoring the R-wire with float switches wired Connect one Dry Contact Sensor wire to the float between the HVAC transformer and the HVAC switch wire that goes to the thermostat. control board NOTE: If the unit has more than one float switch, ensure the Dry Contact Sensor connects to the last float switch in the series.
  • Page 5 ❸ Monitoring float switches with Connect the remaining Dry Contact Sensor wire a dedicated alarm circuit to the C terminal on the HVAC control board. ❹ The switches on the front of the Dry Contact Sensor should be set to NC (black) and 24V (orange). ❺...
  • Page 6 ❸ Monitoring Normally Open or Closed Connect one Dry Contact Sensor wire to the Normally Dry Circuit (with no power running) Opened wire or terminal on the float switch ❹ Connect the remaining Dry Contact Sensor wire to the C terminal on the HVAC control board. ❺...
  • Page 7 Connect to the network using Z-Wave SmartStart ❷ Put the Hub into Add mode. Refer to the Hub NOTE: An Alarm.com account is required for this process. documentation for more information. Power on and add devices one at a time.
  • Page 8: Troubleshooting

    Troubleshooting Deleting the sensor from the network If the Dry Contact Sensor is not TIP: For best results, we recommend having the Hub communicating with the Hub in the same room as the Dry Contact Sensor. ❶ ❶ Press the button on the sensor. The network LED Put the Hub into Delete mode.
  • Page 9 Notices • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that This device complies with part 15 of the FCC rules. Operation is subject to to which the receiver is connected.
  • Page 10 L’antenne(s) utilisée pour ce transmetteur doit etre installé pour fournir une distance de séparation d’au moins 20 cm de toutes les personnes et ne doit pas être co-localisés ou fonctionner en conjunction avec une autre antenne ou transmetteur. Questions? Visit answers.alarm.com or contact your service provider.
  • Page 11 8281 Greensboro Drive 220111 Suite 100 © 2022 Alarm.com. Tysons, VA 22102 All rights reserved.