Advertisement

Quick Links

Table of Content 580320001
..................................................................................................................................
.........................................................................................................................................
..............................................................................................................................
.......................................................................................................................................
Version Nr. 1-5 - 13.06.2022
.........................................................................................................................
......................................................................................................................
.....................................................................................................................
......................................................................................................................
.....................................................................................................................
..................................................................................................................
..........................................................................................................
.........................................................................................................................
..............................................................................................................
......................................................................................................................
.........................................................................................................
................................................................................................................
..........................................................................
Doc. No. 99580320001
2
2
3
4
7
7
8
9
10
11
12
13
14
14
14
15
15
1 / 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 580320001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seifert 580320001

  • Page 1: Table Of Contents

    Table of Content 580320001 1. User manual ..........................2. Legal regulations ......................... 3. Safety instructions ........................4. Settings ............................5. Functional principle ........................6. Technical data ..........................7. Performance graph ........................8. Mounting ............................9. Mounting Principle ........................10. Cut out dimensions ........................
  • Page 2: User Manual

    1. User manual This instruction manual contains information and instructions to enable the user to work safely, correctly and economically on the unit. Understanding and adhering to the manual can help one: Avoid any dangers. Reduce repair costs and stoppages. Extend and improve the reliability and working life of the unit.
  • Page 3: Safety Instructions

    Disregarding the instruction manual Operating error Inappropriate work on or with the unit The use of non-specified spare parts and accessories Unauthorised modifications or changes to the unit by the user or his personnel The supplier is only liable for errors and omissions as outlined in the guarantee conditions contained in the main contractual agreement.
  • Page 4: Settings

    4. Settings Air-air heat exchangers are intended as complementary accessories to large industrial equipment which include a motor-operated fan or blower together with a heat exchanger module. These may also include an electric heater. The fan or blower is intended to recirculate air and allow heat exchange. The heat exchanger is designed for air heat transfer only.
  • Page 5 Programming The operating parameters can be modified using the front keypad. Access differs depending on the type of parameter. Access to configuration parameters is protected by a password that prevents unwanted modifications or access by unauthorised persons. Setting cooling set point, St1: 1.
  • Page 6 Test function Different test functions can be used depending on the combination of keys pressed. Such tests run for the duration of 4 minutes. “SET+▲” tests cooling relays. “SET+▼” tests Alarms and Heater relays Important Notes Whilst programming, if no button is pressed for 10 seconds, the display starts flashing, and after 1 minute returns to the main display without saving changes.
  • Page 7: Functional Principle

    5. Functional principle 6. Technical data Order Number 580320001 Heat exchanger performance 18 W/F Operating temperature range 23°F - 131°F Ambient air circuit: 147 / 324 cfm Air volume flow (system / unimpeded) Cabinet air circuit: 150 / 324 cfm...
  • Page 8: Performance Graph

    7. Performance graph Version Nr. 1-5 - 13.06.2022 Doc. No. 99580320001 8 / 15...
  • Page 9: Mounting

    8. Mounting Danger from electrical voltage The unit must be mounted by specialist personnel (qualified electricians). The personnel must ensure that the cabinet is disconnected from the electrical supply for the duration of the mounting operation. Therefore take the cabinet out of operation, following the relevant instructions before mounting work commences. Danger through incorrect work on the unit.
  • Page 10: Mounting Principle

    9. Mounting Principle Heat exchanger Mounting gasket Slotted stud M6 x 1 inch Enclosure Washer A6.4 M6 Lock nut Version Nr. 1-5 - 13.06.2022 Doc. No. 99580320001 10 / 15...
  • Page 11: Cut Out Dimensions

    10. Cut out dimensions Version Nr. 1-5 - 13.06.2022 Doc. No. 99580320001 11 / 15...
  • Page 12: Dimensions (H X W X D)

    11. Dimensions (H x W x D) Version Nr. 1-5 - 13.06.2022 Doc. No. 99580320001 12 / 15...
  • Page 13: Wiring Diagram

    12. Wiring diagram Power connector Alarm (NO) Alarm (COM) Alarm (NC) Door contact Door contact Version Nr. 1-5 - 13.06.2022 Doc. No. 99580320001 13 / 15...
  • Page 14: Taking Into Operation

    13. Taking into operation As described in the chapter “Technical information”, the unit is controlled in relation to the cabinet internal temperature. The required cabinet temperature can be set on the potentiometer on the controller.The temperature adjustment range is between 32°F (left-hand stop) and 140°F (right-hand stop). The thermostat is pre-set at 95°F.
  • Page 15: Transport & Storage

    1 x O-ring Seifert Systems GmbH Seifert Systems Ltd. Seifert Systems AG Seifert Systems GmbH Seifert Systems Ltd. Seifert Systems Inc. Seifert Systems Pty Ltd. Albert-Einstein-Str. 3 HF09/10 Wilerstrasse 16 Bärnthal 1 Rep. Office 75 Circuit Drive 105 Lewis Road...