HANYOUNG NUX PFD RM Instruction Manual

Advertisement

Quick Links

Fiber Sensor Controller
PFD RM
INSTRUCTION MANUAL
We appreciate you for purchasing HanYoung NUX Co.,
Ltd product.Before using the product you have purchased,
check to make sure that it is exactly what you ordered.
Then, please use it following the instructions below.
Safety information
Before you use, read safety precautions carefully, and use this product properly. The
precautions described in this manual contains important contents related with safety;
therefore, please follow the instructions accordingly. The precautions are composed of
DANGER, WARNING and CAUTION.
WARNING
1. To prevent defection or malfunction of this product, supply proper power voltage in
accordance with the rating.
2. Since this product is not designed with explosion-protective structure, do not use it at any
place with flammable or explosive gas.
3. Remove this product while the power is off. Otherwise, it may cause malfunction or
electric shock.
4. Due to the danger of electric shock, use this product installed onto a panel while an
electric current is applied.
CAUTION
1. The contents of this manual may be changed without prior notification.
2. If you use the product with methods other than specified by the manufacturer, there may
be bodily injuries or property damages.
3. Avoid continuously switching the power source On and Off.
4. Use a dry cloth to wipe off the substance when cleaning the lens or cases. Never use
thinner or organic solvents.
5. Do not use this product at any place with much dust, vibration or impact.
6. Before inserting power source, make sure that the circuit wiring is properly connected.
7. In the case of wiring loaded inductors such as DC Relay and others to output, use diode,
varistor and others to prevent surge.
8. To avoid malfunction caused by noise, do not put high voltage or power line with sensor
wire in a same conduit
9. Make its wiring be shorter as possible and wire extension shall be within 30 m.
10. Consider the fact that the sensing distance may be varied in accordance with the size,
color, surface condition, material, glossy, non-glossy or others of a sensing object.
11. Prevent strong disturbance light such as sunlight and others which directly enter into the
directional angle of the sensor by putting a glare shield.
12. In the case of using multiple sensors (more than 2 sensors), there is a possibility of
malfunction caused by mutual interference so, for Through-Beam type, sensors shall be
installed in a divergent way or there shall be proper distance between them.
13. When using the Switching Power Supply as the power source, earth the Frame Ground
(F.G) terminal and be sure to connect the noise-eliminating condenser between 0 V and
F.G.
Power
Supply
(SMPS)
If you do not follow the contents described in the safety information then it is possible to be
a cause of the product's malfunction so please follow them.
Ordering information
PFD
10 bit A/D 4Digit
Light source
Red LED
Multi-functions(MARK/RPM/COUNTER)
Use
NPN Open collector
External output
PNP pen collector
Multifunction: With built-in RPM/Count function, control output is possible
without a separate meter.
C(0.01 -0.1 /500 V)
Photo
- Noise Eliminating
sensor
Condenser -
Frame
HEAD OFFICE
1381-3, Juan-Dong, Nam-Gu Incheon, Korea
TEL: (82-32)876-4697 FAX : (82-32)876-4696
Rating
Type
Kinds
NPN
Model
PNP
Rated Voltage
Current Consumption
Main
Output
Subsidiary
External Input
Mtensity of light
Multi
COUNTER
-functions
RPM
Output
On/Off Delay
Light source / Wavelenght
Protection Circuit
Response time
Varation rate
Display form
Sensitivity fixation
Additional functions
Operating Ambient illumination
Operating Ambirut temp.
Operating Ambient Humidity
Vibration Resistance
Shock Resistance
Dielectric Strength
Insulation Resistance
Connection Method
Accessory
Multi-functions
Counter
Multi-functions
Cautions) Use by combining the Fiber Unit in the form of transmission type at the time of
RPM/Count Measurement.
Malfunction can occur from the increase in the light receiving change range by speed
when using for the reflection purpose.
Distance measurement at the optical measurement mode changes in accordance with the
Fiber Cable and within 20m is recommended.
Dimension
Multi functions
PFD-RMN
PFD-RMP
12-24 V d.c
10 % (Ripple 10 % Max.)
50 mA Max.
Control : Open collector output, 100 mA
Stability :Open collector output, 100 mA
Remote / Reset input
0-1000
400 cps, Up/Down, 0~9999
12~9999 rpm
(Light On) / (Dark On) Output
NORMAL , ON DELAY, OFF DELAY, ONE Shot Time Output
1 ~ 9999 ms
Wavelength / 660 nm
Protection circuit from reversed power supply connection, Output short-circuit protection
1ms Max
10 % Max
LED 7, 4 digits FND
Auto-teaching, Manual
Adjustable bightness, 180 rotation display
Display time fixation, Zero reset, Initial reset, Lock function
Sunlignt : 10,000 lx Max., Incandescent lamp : 3,000 lx Max.
Operating : -10
~+ 55
, Storage : -25
35 ~ 85 % R.H.
10-55 Hz(Cycle for 1 minute), Double amplitude : 1.5 mm, in each direction X Y Z for 2 hours
500
(50 G), X Y Z for 3 times
500 V a.c (50-60
Above 20
DIN rail
cable 2 m, 5 P, 4
Bracket
UP / DOWN mode, Free scale 1~999
Range: 0 ~ 9999
Counting speed: 400 cps (50 % duty )
Output mode : N, F, C, R, K, P, Q, A 8 kinds
External reset : Min. signal width 5 ms
Range : 0 ~ 9999 rpm
RPM
Free scale : 1 ~ 1000 Measring
MK0801E080108
~ +70
(Without freezing)
for 1 minute)
(500 V d.c)
Speed guard output
Cycle setting

Advertisement

loading

Summary of Contents for HANYOUNG NUX PFD RM

  • Page 1 MK0801E080108 Fiber Sensor Controller PFD RM INSTRUCTION MANUAL We appreciate you for purchasing HanYoung NUX Co., HEAD OFFICE Ltd product.Before using the product you have purchased, 1381-3, Juan-Dong, Nam-Gu Incheon, Korea check to make sure that it is exactly what you ordered.
  • Page 2 PAGE1: Sensor Manual Sensitivity Set Up Page Wiring PAGE2: Sensor Output Mode Set Up Page PAGE3: Count/RPM Function Set Up Page Circuit wiring & Fixture PAGE4: Additional Function Set Up Page CNT: Holds one operation mode from Up Counter, Down Counter, and RPM display functions.
  • Page 3 1. When using at the Counter or RPM Measurement Mode, set up with the AutoTeaching Mode maximum value of [1-3] hysteresis and [1-4] safe region (stability). (When using transmission type fiber unit) Auto Teaching Mode Entry: Press at the RUN Mode. ( TEAC => txxx ) 2.
  • Page 4 Output operation mode [3-5] Function and output explan ation in RPM mode Output mode[3-5] Explannation Between high limit value[3-3] and low limit value[3-4] (Standard) OUT1 ON, OUT2 OFF More than high limit value[3-3] OUT1 ON (High) Counter Function and Set Up Method More than low limit value[3-4] OUT2 ON More than high limit value[3-3] OUT1 ON (Low)