AutoTeaching Mode
Auto Teaching Mode Entry: Press
Auto Teaching Mode Removal: Restores to the RUN Mode execution from the Teaching
Mode when
is pressed.
The set up outline described in the below is the set up method at the Teaching Mode.
<1 Point Teaching > when detecting from a specific
location of walk
Place it at the location for detecting the walk
Complete the set up by pressing
(once: txxx switch, twice: _OK_ )
(The set up value becomes the optimal
value of 300~700 range.)
Walk : Object, Object to be Detected
<2 Point Teaching> when detecting delicate walk
(limited region detection)
Out if it is over 1/2 of the walk light amount and
background light amount
Place it at the location for detecting the walk
Press
once. (Automatic Gain Adjustment)
( txxx switch)
Remove the walk initially placed at the location.
(Only background remains)
Complete the set up by pressing
<Maximum Light Amount> when detecting walk using transmission type fiber
Place it at the location for detecting the walk
Complete the set up by pressing
(once: txxx switch, twice: _OK_ )
<Auto Teaching> when detecting moving walk without stopping it
Move the walk from the conveyor or operate the body of revolution
(motor, etc.)
Difference of light amount will be automatically distinguished for set
up after about 10 seconds when
( AT_9 -> AT_8 ... AT_0 -> _OK_ )
Viewing Adjust Value at the Teaching Mode
When verifying the adjust value after 1 Point, 2 Point, Maximum Light Amount and Auto Teaching
Displays the adjust value when
The sensor returns to the Teaching Mode when
Manual sensitvity
SENSOROUTPUT
setting
(RUN MODE)
(Basic input setting)
Set
1 Group
2 Group
value
value
DARK/LIGHT
GAIN
7
ON DELAY
ADJUST
500
OFF DELAY
HYSTERESIS
10
STABILITY
ONE SHOT
20
AUTO
TIME
INPUT SW
CHANEL
Refer to the Parameter Group Set Up for the Details on the Adjusted Values.
1) Move to the next parameter group by pressing
2) Current mode and current set up condition is displayed when moving the parameter.
3) Set up can be changed by firmly pressing on to
4) Just move the Slide S/W to RUN or CNT to move to the executive mode after completing the set up
Parameter
Manual sensitivity set
Move to Group 1
in FUN mode
Parameter menu and display
GAIN
Move to parameter 2 Group
ƒU
ƒU
ADJUST
ƒU
HYSTERESIS
ƒU
STABILITY
ƒU
1) Move to the next parameter group by pressing
2) Current mode and current set up condition is displayed when moving the parameter.
3) Set up can be changed by firmly pressing on to
4) Just move the Slide S/W to RUN or CNT to move to the executive mode after completing the set up,
at the RUN Mode. ( TEAC => txxx )
twice
once. ( _OK_ )
twice
is pressed.
is pressed once (if the adjust value is 540, A500 )
is pressed once again. ( txxx )
COUNTER/RPM SET
(CNT MODE )
Set
Set
3 Group
4 Group
value
L
MODE(UP,DN,RPM)
UP
LOCK
OFF
PRESCALE
1
BRIGHT
OFF
SETTING HI
100
BRIGHT TIME
OFF
SETTINGLOW
DISPLAY 180
100
OUT1 MODE
DEFAULT
(CNT)C
CH1
ONE SHOT TIME
(RPM)L
50
when the parameter is displayed.
for long time.
Explannation
Range
Set up 8 levels of
amplifying rate for the
1(min)
amplifying circuit of the
~8(max)
light receiver.
Set up the sensitivity
5-995
(criterion value)
1~10 %
Set up GAP of the
criterion at the time of
2~10 %
deciding the presence of
walk.
Set up the safe region at
the time of deciding the
HYSTERESIS
presence of walk.
when the parameter is displayed.
for long time.
1. When using at the Counter or RPM Measurement Mode, set up with the
maximum value of [1-3]
hysteresis and [1-4] safe region (stability). (When using transmission type fiber unit)
2. In the case of Auto Teaching at the RUN Mode, GAIN [1-1] and
ADJU [1-2] values will change automatically.
Move to Group 2
Parameter menu and Display
Move to parameter 3 Group
ƒU
ƒU
ƒU
ƒU
ƒU
ƒU
ƒU
1) Move to the next parameter group by pressing
2) Current mode and current set up condition is displayed when moving the parameter.
3) Set up can be changed by firmly pressing on to
4) Just move the Slide S/W to RUN or CNT to move to the executive mode after completing
the set up,
Move to Group 3
Parameter menu and Display
Move to parameter 4
ƒU
Group
ƒU
Set
value
ƒU
DS
7
OFF
0
ƒU
-
ƒU
ƒU
ONE SHOT TIME
ƒU
Setting KEY
OUT2 (STB LED) is outputted whenever the sensitivity value is greater than the [1-4] value.
(Use for verifying the presence of calculation.)
:
1) Move to the next parameter group by pressing
:
Setting value
2) Current mode and current set up condition is displayed when moving the parameter.
3) Set up can be changed by firmly pressing on to
change
4) Just move the Slide S/W to RUN or CNT to move to the executive mode after completing the set up
:
Set Up Example
Setting
Free Scale Set Up [3-2]
completition/
Example 1) counting one by one for input of 5 at the Counter Mode (Division Set Up 5)
revert
Example 2) Counting in three for input of 1 at the Counter Mode, 3+1000=set up 1003
Example 3) 1/60 (set up 60) since 60rpm is 1cps when displaying as CPS at the RPM Mode
Example 4) displaying with RPMx5 for input of 5 at the RPM Mode (Set Up 5)
(Displaying RPM with 0.2 input as a base)
Setting HI [3-3]/Setting LOW [3-4]
Example 1) Up Counter: when setting 100 as the setting value (Set Up [3-3]: 100)
Example 2) Down Counter: when counting down from 200 to 0 (Set Up [3-3]: 200)
Example 3) RPM Meter: when assigning output conditions by specifying rpm range of
500~600 (Set Up [3-3] HI: 600, Set Up [3-4] LOW: 500)
in FUN mode
Explannation
Set up the Up Counter,
Dark_Light
Down Counter,
and RPM Meter Modes.
Set up the free scale.
ON_Delay
Set up the adjust value at
the Counter.Set up the
OFF_Delay
maximum value at RPM.
Set up the minimum
value at RPM.
ONE Shot
(Exclusive RPM Use)
Time
Set up the output
motion mode of Counter
and RPM Meter.
E-IN
Refer to the chart for
details of the motion mode.
Set up One Short
Time of Out1 Port.
CHANEL
(Unit: msec)
in FUN mode
Explannation
Set up the Up Counter,
MODE
Down Counter,
and RPM Meter Modes.
1-999(Input / PRE=Display value)
Set up the free scale.
1001-1999(Input PRE=Display value)
PRESCALE
Set up the adjust value
at the Counter.Set up
the maximum value
at RPM.
SETTING HI
Set up the minimum
value at RPM.
(Exclusive RPM Use)
SETTING LOW
Set up the output
motion mode of Counter
and RPM Meter.
Refer to the chart for
details of the motion
mode.
OUT1 MODE
10,20,30,40,50,100,200,
300,400,500,1000,2000,
Set up One Short
3000,4000,5000 msec
Time of Out1 Port.
(
(Unit: msec)
Range
Setting KEY
: Setting value
:Light ON
change
:Dark ON
Setting
completitio/revert
9999 ms
Setting value change
: Setting
None
completitio/revert
1-TE
AUTO
Setting value
ch1
change
: Setting
ch2
completitio/revert
when the parameter is displayed.
for long time.
Range
Setting KEY
Rpm Meter
: Setting
value change
Up Counter
: Setting
Down Counter
completitio/revert
1 -9999
: Setting value
change
Counter operation
: Setting
completitio
RPM operation
/revert
DOWN value
UP value)
when the parameter is displayed.
for long time.