Wiring
Circuit wiring & Fixture
Input / Output circuit
NPN type
Name of parts
LED Display (State)
Displays the state of Fiber Sensor
OUT: Lights on for interface output (OUT1)
STB: Displays safe regions at the RUN Mode (OUT2))
Sensor input display is on over the set up region at the RPM/Count Mode
D/L: Lights on for Light On and Lights off for Dark On
OND: Lights on when On Delay is set at the Output
OFD: Lights on when Off Delay is set at the Output
RUN: Lights on when operating at RUN
CNT: Lights on when operating at CNT (Up Counter / Down Counter / RPM)
(RUN and CNT simultaneously light on when operating at the RPM Mode)
Push Button ( UP,
DN)
Function change and value set up at each executive mode (RUN, FUN, CNT)
Slide S/W (RUN, FUN, CNT)
Sets up executive modes and priority operation at all functions
RUN: General Fiber Sensor Operation Mode
Various light amount set up & display function
(Ordinary Light Amount Display / Bar Display / Maximum,
Minimum HOLD Display / Percent Display)
Displacement Set Up function (OFFSET)
Various Auto Teaching Function
FUN: Various Additional Function Set Up Mode
PNP type
Segment (4 Digit FND) Display
Displays bars at the Number, Letter, and
Bar Display Mode such as the amount of
light entering, mode error message, set up
values, and set up items
PAGE1: Sensor Manual Sensitivity Set Up Page
PAGE2: Sensor Output Mode Set Up Page
PAGE3: Count/RPM Function Set Up Page
PAGE4: Additional Function Set Up Page
CNT: Holds one operation mode from Up Counter, Down Counter, and RPM
display functions.
(FUN
Operates with Counter or RPM display
according to the function set at the [3-1] Mode.)
Caution: Refer to the Parameter Chart for the Detailed Set Up and function of FUN
Optical Fiber Unit Input Hole External Diameter:
Depending on receiving level,OUT,
STB operation
Delay setting and Output operation
(in Light ON)
Various display function
How to operate a button
press UP button in short
press UP button in long
180 rutation display
(Changeable at FUN mode[4-4]
0 select
180 select
Changeable a display mode press at RUN mode
Light Volume
BAR Display
Light Volume
Light Volume is more than
More than Low limit value of Stability
More than Low limit value of Adjust
Less than High limit value of Adjust
Less than High limit value of Stability
More than High limit walue of(Stability+10)
Max. / Min. HOLD display
Display Max. and Minimum value during
flickering
Percentage display
Display
as standard
If set 300 as setting value
- If light value is 300,
display
- If light value is 990,
display
2.2 mm Fiber unit
The set up range
of
hysteresis
1~10% of the criterion
value.
The set up range of
stability is 2~20% of
the criterion value and
is greater than the
hysteresis value.
press DN button in short
press DN button in long
ƒU
ƒU
ƒU
ƒU
is