Output operation mode [3-5]
Function and output explan ation in RPM mode
Output mode[3-5]
Between high limit value[3-3] and low limit value[3-4]
(Standard)
OUT1 ON, OUT2 OFF
More than high limit value[3-3] OUT1 ON
(High)
More than low limit value[3-4] OUT2 ON
More than high limit value[3-3] OUT1 ON
(Low)
More than low limit value[3-4] OUT2 ON
Function Output explan ation in Counter
O
U
T
P
U
T
M
o
d
e
One shot time setting in FUN mode
Move to Group 4
in FUN mode
Parameter menu and Display
Explannation
FUN mode lock
Lock
(refer to 5)
ƒU
Move to parameter 1
Group
Brightness setting
ƒU
and FND brightness
Bright
control
ƒU
Bright Time setting
Brightkeeping time
Bright
Time
ƒU
Display rotation
Display
(180rotation)
180
ƒU
Default setting
Default
(Initial value setting)
ƒU
1) Move to the next parameter group by pressing
2) Current mode and current set up condition is displayed when moving the parameter.
3) Set up can be changed by firmly pressing on to
4) Just move the Slide S/W to RUN or CNT to move to the executive mode after completing the set up,
5) LOCK Release Method: Press
Explannation
One shot value
Keep up value
Explanations
Calculation stops and output is on when the
adjust value is reached.
The output off calculated value is reset at the
rising Edge of Reset.
Calculation begins at the declining Edge of
Reset.
Calculation continues even after reaching the
adjust value and the output stays on.
The output off calculated value is reset at the
rising Edge of Reset.
Calculation begins at the declining Edge of
Reset.
The output is generated as one short when
the adjust value is reached and the
calculation value is released with the Reset.
The output is generated as one short when
the adjust value is reached and when the
calculation stop one short time is over, the
calculated value starts calculation with the
Reset.
The output is generated as one short when
the adjust value is reached.
The calculated value is reset at the rising
Edge of Reset
Calculation begins at the declining Edge of
Reset
The output is generated as one short when
the adjust value is reached and the
calculation value is reset.
It doesn t calculate during the one short
period.
The output is generated as one short when
the adjust value is reached and the
calculated value resets and calculation
begins at the declining edge where the one
short ends.
The output is generated as one short when
the adjust value is reached and the
calculation stops.
The calculated value is reset at the rising
Edge of Reset
Calculation begins at the declining Edge of
Reset
Range
Setting KEY
: Enable
: Disable
[1-7]stages
:
:
OFF, 5, 10, 15, 20,
30 sec
setting value change
1, 2, 3, 4 min
: setting
completition/revert
: normal
:180 rotation
when the parameter is displayed.
for long time.
in order
Counter Function and Set Up Method
It is combining the counter function to the
ordinary fiber sensor function. It can be set
up to output when it yields arbitrary
calculated value by calculating the walk. The maximum calculated range is 9999. It can set
up Up Counter and Down Counter
and supports the output of free scale and 8 types of motion mode that is capable of division/
set up. At this time, the remote
input function is changed to external reset use. Free scale is capable of displaying division
and .
OUT2 can be used as sensor output and is generated when the display value is changed.
Initialization of Calculation Value at the state of CNT Mode Execution
The calculation display is `0' at the Up Count Mode and is Setting value [3-3]
at the Down Count Mode
when
is pressed. Calculation stops while the key is pressed on.
Initialization of calculated value with the remote reset external input
Set up example at the Counter Mode (Refer to the parameter set up for the details of set up.)
Caution) Must carry out sensor sensitivity set up process as well.
Set Up Example Calculate up to 350 by counting one each for input of 3 at the Up
Counter Mode and then one short time
Stop the calculation at 50 msec output. Reset when the remote reset is displayed and set up
to begin the calculation.
FUNCTION
PAGE
Operation Mode
[3-1] [MODE]
Free scale
[3-2] [PRE]
Setting Hi
[3-3] [S-HI]
Setting Low
No use in Counter mode
Output Mode
[3-5] [OUTM]
One Shot Time
[3-6] [ONES]
RPM Meter Function & Set Up Method
It is the RPM Display Function. It is capable
of measuring from 1~9999rpm and supports
speed monitoring output and
maximum/minimum adjust output. The speed monitoring output is materialized to give out
alerting output when goes beyond
10% of the adjust value. With the function support of free scale (0001~0999), CPS value can
be displayed when set up at 60.
Also, it supports the division and πË¡÷ functions. However, the display value cannot exceed
400 CPS/ps value. The output is
generated in one short.
Set Up Example at the RPM Mode (Refer to the parameter set up for the details of set
up.)
Caution) Must carry out sensor sensitivity set up process as well.
Set Up Example RPM is displayed in the case of one rotation based on the input of one for
exclusive use
of RPM display and the output is generated by having 500rpm to 550rpm as standard. For
between
500~550, set up as OUT1 ON / OUT2 OFF.
FUNCTION
PAGE
Operation Mode
[3-1] [MODE]
Free scale
[3-2] [PRE]
Setting Hi
[3-3] [S-HI]
Setting Low
[3-4] [S-LO]
Output Mode
[3-5] [OUTM]
One Shot Time
[3-6] [ONES]
SET VALUE
REMARK
[Up]
UP Counter setting
[0003]
3 setting
[0350]
350 value
[n]
Refer to counter mode table
[500]
500 msec setting
SET VALUE
REMARK
[Rpm]
RPM Mode setting
[0001]
1setting
[0550]
OUT1 set value
[0500]
OUT2 set value
[S]
Output Mode
[OFF]
Real time output

Advertisement

loading

This manual is also suitable for:

Pfd-rmnPfd-rmp