Operational Characteristics 1000 lb system
Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
Freeze
Harvest
System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
Suction at Ice Making Section, end of Freeze
Suction at Ice Making Section, Harvest
Discharge at Condensing Unit: Freeze - 5 minutes in
Headmaster maintains a minimum discharge
pressure during freeze of:
·
217 PSIG + 25, -15 PSIG
CPR Valve Setting: 55 - 60 PSIG.
Note: CPR allows a maximum low side pressure at
the CP unit's compressor. Maximum only occurs
during harvest.
Refrigerant Charge
·
272 oz
Compressor Amps
·
Single Phase 8 to 10
·
Three Phase 5 to 7
Batch Weight: 8 lb
Discharge Pressure Cut Out Switch
·
Cuts Out at: 450 PSIG
·
Resets at: 350 PSIG
Prodigy Eclipseä 600, 800, 1000
70/70/50
6 to 8 minutes
1 to 1.5 minutes
February 2008
Page 49
90/90/70
8 to 10 minutes
1 to .5 minutes
70/70/50
90/90/70
26 to 31 PSIG
27 to 32 PSIG
85 to 105 PSIG
90 to 110 PSIG
230 to 250 PSIG
230 to 250 PSIG
120/110/100
16 to 18 minutes
.5 to 1 minutes
120/110/100
30 to 35 PSIG
140 to 160 PSIG
345 to 365 PSIG