Page 1
GlideScope Cobalt AVL System User’s Manual and Quick Reference Guide 0900-2654-04-20...
Page 2
GlideScope Cobalt AVL System Quick Reference Guide...
Page 3
For the most up-to-date information, see the online manuals on verathon.com. GlideScope video laryngoscope systems are CE marked in accordance with the Medi- cal Device Directive, and the Verathon Inc. quality system is Quality System Certified to ISO 13485:2003 standards.
Page 5
Cobalt AVL System is the digital, full-color monitor. ® The front of the monitor includes the buttons you use to operate the Cobalt AVL. There are also indicator lights for different operation status of the system. The back panel of the monitor includes the sockets and ports for connecting the power cord, video baton cable, external video cable, and USB drive.
Page 8
® Cobalt AVL Video Baton to temperatures above 60°C. The GlideScope Cobalt AVL is a combination of a nonsterile, reusable video baton and a ® sterile, single-use Stat. Low Level Disinfection is recommended for the Cobalt AVL Video Baton after every patient use. High Level Disinfection is required for the video baton when it is visibly soiled.
Page 9
Footnotes: * The Cobalt AVL Video Baton is a nonsterile reusable device, which is protected from contact with mucous membranes and non intact skin by the Stat (sterile, single-use) when used as intended. Low Level Disinfection is recommended for the Cobalt AVL Video Baton after every patient use.
Page 10
® GVL System (reusable) Ranger Single Use System Ranger System (reusable) Cobalt AVL System (single use) Note: System configurations vary. The Cobalt AVL and Ranger Single Use Video Batons are reusable. *For use with endotracheal tubes 6.0 mm and larger.
Page 12
Federal (United States) law restricts this device to sale by, or on the order of, a physician. The GlideScope Cobalt AVL System should be used only by individuals who have been trained and authorized by a physician, or by health care providers who have been trained and authorized by the institution providing patient care.
Page 13
Product Information Product Description The GlideScope Cobalt AVL System is designed for “1st pass success.” The Cobalt AVL provides a consistently clear view of a patient’s airway, enabling quick intubations. The Cobalt AVL design is based on the GlideScope GVL ®...
Page 14
The main component of the GlideScope Cobalt AVL System is the digital, full-color monitor. The front of the monitor includes the screen and the buttons you use to operate the Cobalt AVL. There are also indicator lights for different operation status of the system.
Page 15
Progress Confirmation: these animations show the Cobalt AVL system's progress when shutting down or playing the tutorial video. Download New: indicates button to press to download all new recordings (not previously downloaded).
Page 16
IV pole. GlideScope Cobalt AVL System Configurations You can set up the GlideScope Cobalt AVL System in two configurations: Cobalt AVL on IV pole Cobalt AVL on mobile stand Quick Reference Guide...
Page 17
Power key for 10 seconds to power down the system. If the Cobalt AVL Video Baton or Stat are stored in cold conditions, addition- al warming time may be required for optimal performance of the anti-fog feature.
Page 18
Connectors and cable insulation integrity To ensure patient safety, users should perform a routine inspection of the GlideScope Cobalt AVL Video Baton before every use to ensure that all endoscopic components are free of unintended rough surfaces, sharp edges, protrusions or cracks.
Page 19
It is understood that all items in this chart will be used as intended. * The Cobalt AVL Video Baton is a nonsterile, reusable device, which is protected from contact Note: with mucous membranes and non intact skin by the Stat (sterile, single-use) when used as intended.
Page 20
GlideScope Cobalt AVL System ® Table 2: Chemical Compatibility and Disinfection Methods for Cobalt AVL Video Baton Active Disinfection Caution/ Compatibility Conditions Ingredient Level Comments Enzymatic Surface As per chemical debridement General cleaning only in manufacturer's agent/ hospital grade preparation for...
Page 21
GlideScope Cobalt AVL System ® Table 2: Chemical Compatibility and Disinfection Methods for GlideRite Rigid Stylet ® Active Disinfection Caution/ Compatibility Conditions Surface Enzymatic Ingredient Level Comments General As per chemical cleaning only in debridement hospital manufacturer's preparation for agent/...
Page 22
Cobalt AVL System ® Cleaning the GlideScope Cobalt AVL Video Baton The GlideScope Cobalt AVL Video Baton, which is protected by the GVL ® Stat, is not intended to have direct patient contact. Do not place the GlideScope Cobalt AVL Video Baton in the cradle Caution if it is contaminated.
Page 23
GlideScope Cobalt AVL System ® Cleaning the GlideScope Cobalt AVL Monitor Wipe the exterior of the monitor with IPA (70% isopropyl alcohol), bleach (100 ppm) or a mild detergent and water. Cleaning the GlideScope Cobalt AVL Cradle Wipe the cradle with a standard hospital grade surface cleaning product.
Page 24
GlideScope Cobalt AVL System ® Symbol Directory Symbol Meaning Type BF equipment Class II Electrical equipment CE marking in accordance with the Medical Device Directive ( for Sterile Devices) 0413 Canadian Standards Association (CSA) mark of certification to applicable standards for electromedical...
Page 25
GlideScope Cobalt AVL System ® GlideScope Specifications, Standards and Approvals General Specifications Classification: Electrical Class II, Applied Part BF Line Voltage: Range: 100–240 VAC, 50 and 60 Hz Connect to a medical grade power supply DC Power Supply: 12V DC, 2.5A max Fuse: Internal 2.5A Hold / 5A Trip, 15V max...
Page 27
GlideScope Cobalt AVL System User’s Manual...
Page 29
GlideScope Cobalt AVL System User’s Manual...
Set the GlideScope Cobalt AVL System Parameters (Optional)......21 Setting Up the GlideScope Cobalt AVL System ..... 22 Set Up the GlideScope Cobalt AVL on a Mobile Stand ........22 Set Up the GlideScope Cobalt AVL on an IV Pole ..........26 Using the GlideScope Cobalt AVL System ......27 Select the Correct Video Baton and Stat ............27...
Page 32
® General Maintenance Information ..............35 General Cleaning and Disinfection Information ..........36 Cleaning and Disinfecting the GlideScope Cobalt AVL System......39 Cleaning the GlideScope Cobalt AVL Video Baton ..........40 Disinfecting the GlideScope Cobalt AVL Video Baton ........41 Cleaning the GlideScope Cobalt AVL Monitor ............41 Cleaning the GlideScope Cobalt AVL Cradle............41...
Product Information ® Product Information The GlideScope Cobalt AVL System is designed for “1st pass success.” The Cobalt AVL provides a consistently clear view of a patient’s airway, enabling quick intubations. The Cobalt AVL design is based on the GlideScope GVL, which is clinically proven to achieve a Cormack-Lehane Grade I or II view 99 percent of the time.
Page 34
Additionally, it is useful for teaching purposes, verification of endotracheal tube (ETT) placement, nasal intubation, and ETT exchange. The Cobalt AVL is easy to learn, use, and teach. It is ideal for acute care settings and emergency environments. It also integrates into standard ED, OR, ICU, and NICU applications.
Federal (United States) law restricts this device to sale by, or on the order of, a physician. The GlideScope Cobalt AVL System should be used only by individuals who have been trained and authorized by a physician, or by health care provid- ers who have been trained and authorized by the institution providing patient care.
User's Manual before ® using the GlideScope Cobalt AVL System. Failure to do so may result in injury to the patient, compromise the performance of the system, and may void the system warranty.
Page 37
Connect the device to an outlet on a circuit different from that to which the other device(s) is (are) connected • Consult your Verathon Medical Customer Care representative Note: The GlideScope Cobalt AVL System must be used with the cables supplied by Verathon to maintain electromagnetic interference ®...
The main component of GlideScope Cobalt AVL System is the digital, full-color monitor. The front of the monitor includes the screen and the buttons you use to operate the Cobalt AVL. There are also indicator lights for different operation status of the system.
Progress Confirmation: these animations show the Cobalt AVL system's progress when shutting down or playing the tutorial video. Download New: indicates button to press to download all new recordings (not previously downloaded).
Buttons, Icons, and Connections GlideScope Cobalt AVL System ® GlideScope Cobalt AVL Monitor Back Panel Figure 3 Cobalt AVL back panel Power Socket: Connect Video Baton Port: USB Port: Connect the barrel plug from the Connect the video a USB drive to down- 12V power adaptor.
Cobalt AVL System ® Getting Started Before you can use your GlideScope Cobalt AVL System, you must inspect the components, set up the system, and perform a functional test. Before You Start Before you use the GlideScope Cobalt AVL System for the first time,...
+31.30.68.70.570 (Europe) For additional contact information, see page 50. GlideScope Cobalt AVL System Configurations You can set up the GlideScope Cobalt AVL System in two configurations: • Mount it on a mobile stand (Figure 4). For specific set up instructions, see page 22.
90 minutes before it needs to be recharged. For optimal battery life, make sure that the battery is fully charged before you try to use the Cobalt AVL in battery mode. You should charge the battery at temperatures between 0–40 °C.
Black connector ring To insert the Cobalt AVL Video Baton into the sterile, single-use GVL Stat: Insert the Video Baton into the GVL Stat ® 1. Before you slide the baton into the stat, make sure that the logo on the side of the baton and the logo on the side of the stat are aligned.
Getting Started GlideScope Cobalt AVL System ® To ensure optimal results of the anti-fog heating feature on the GlideScope GlideScope Anti-Fog Feature video laryngoscope, perform the following steps: 1. Prior to use, open the GVL Stat pouch, but do not remove the Stat ®...
Cobalt AVL System ® Perform a Functional Check Before you use the GlideScope Cobalt AVL System for the first time, perform the following functional check to assure that the system is working properly. Please contact your Verathon Medical Customer Care Representative if your Cobalt AVL System does not function as described below.
Set the GlideScope Cobalt AVL System Parameters (Optional) Verathon ships the Cobalt AVL System with the time set to Greenwich ® Mean Time (GMT). You can change the system time and date to match the local time at your specific location.
On an IV pole (Figure 16) Set Up the Cobalt AVL on a Mobile Stand You can set up the Cobalt AVL System on a mobile stand. The stand makes it easy for you to move the system from one location to another.
Page 49
GlideScope Cobalt AVL System Setting Up the Cobalt AVL ® Attach the center pole to the base 1. Remove the hex bolt and washers from the bottom of the pole. 2. Insert the bottom end of the pole into the top of the base.
Page 50
Locking pin in unlocked position Adjust the Monitor Angle Before you start using the GlideScope, adjust the angle of the monitor for optimal viewing. The ideal angle minimizes glare and maximizes visibility. 1. Turn the angle adjustment knob counterclockwise. 2. Tilt the monitor to the desired angle.
Page 51
Hook video knob baton cradle to GVL cradle To attach the GlideScope Video Baton Cradle directly to the mobile stand or IV pole: 1. Screw the center pole clamp to the GlideScope Video Baton Cradle (Figure 18). 2. Attach the center pole clamp and GlideScope Video Baton Cradle to the mobile stand or IV pole, and then turn the black knob clockwise to tighten (Figure 19).
Cobalt AVL System ® Set Up the GlideScope Cobalt AVL on an IV Pole You can set up the Cobalt AVL System on an IV pole (Figure 20). Figure 20 Cobalt AVL on IV pole Cobalt AVL Monitor IV-Pole Mount Cradle ®...
Power key for 10 seconds to power down the system. Select the Correct Video Baton and Stat Make sure that you select the Cobalt AVL Video Baton and GVL Stat that best fit your patient. Verathon recommends the following: ®...
Cobalt AVL System ® Set Up the Video Baton and Stat To set up the Cobalt AVL Video Baton and GVL Stat, you must connect the ® baton to the monitor, and then insert the baton into the appropriate size stat.
Page 55
GlideScope Anti-Fog Feature To ensure optimal results of the anti-fog heating feature on the GlideScope video laryngoscope, perform the following steps: 1. Prior to use, open the GVL Stat pouch, but do not remove the Stat from the packaging (to keep the Stat clean until ready for use).
Stat is a sterile, single-use device. After each use, it should ® be removed from the Cobalt AVL Video Baton and disposed of properly. To remove the Cobalt AVL Video Baton from the GVL Stat: 1. Hold the stat in one hand.
Using the Cobalt AVL ® Start Recording The Cobalt AVL System records video using memory inside the monitor. 1. Power on the system. 2. To start recording press the Record button. 3. When you are ready to stop recording, press the Record button again.
® inserted down the midline of the tongue to the epiglottis. • The Cobalt AVL Video Baton with a GVL Stat may be used to produce a Macintosh style lift of the epiglottis, or to produce a Miller lift. • Intubations using the Cobalt AVL Video Baton with a GVL Stat only require approximately 0.5–1.5 kg (1–3.5 lbs) of lifting force.
ET tube. • Carefully introduce the distal end of the ET tube between the vocal folds. • When introducing the GlideScope and/or the endotracheal tube, look directly into the mouth to avoid damaging the endotracheal tube cuff, the patient’s teeth, or soft tissues such as the soft palate or tonsils.
Page 60
The download process to a USB drive can take up to 40 minutes when all files are being downloaded. Therefore, make sure that you do not need to use the GlideScope for the duration of the download process. You can stop the download process at any time. If you stop the process before downloading is complete, none of the video files will be saved on the USB drive.
Cleaning the GlideScope Cobalt AVL System is an important part of maintaining the system. Make sure that the system is clean before each use. You should also examine the Cobalt AVL periodically to make sure it is operating correctly. General Maintenance Information Periodic inspections should be performed to ensure safe and effective operation.
It is understood that all items in this chart will be used as intended. * The Cobalt AVL Video Baton is a nonsterile, reusable device, which is protected from contact Note: with mucous membranes and non intact skin by the Stat (sterile, single-use) when used as intended.
Page 63
Cleaning the Cobalt AVL GlideScope Cobalt AVL System ® Table 3: Chemical Compatibility and Disinfection Methods for Cobalt AVL Video Baton Active Disinfection Caution/ Compatibility Conditions Enzymatic Surface Ingredient Level Comments As per chemical debridement General cleaning only manufacturer's agent/...
Page 64
Cleaning the Cobalt AVL GlideScope Cobalt AVL System ® Table 4: Chemical Compatibility and Disinfection Methods for GlideRite Rigid Stylet ® Active Disinfection Caution/ Compatibility Conditions 2.0% – exposure Ingredient Level Comments for minimum 20 minutes at Glutaraldehyde Up to 3.4% High 20 °C or as per...
Cobalt AVL Video Baton is heated above 60 °C. A gray or white indicator does not indicate overheating. Do not use autoclaves or pasteurizers for the Cobalt AVL system. Caution Use of such methods will cause permanent device damage and void the warranty.
Cobalt AVL System ® Cleaning the GlideScope Cobalt AVL Video Baton The GlideScope Cobalt AVL Video Baton, which is protected by the GVL ® Stat, is not intended to have direct patient contact. Do not place the GlideScope Cobalt AVL Video Baton in the cradle Caution if it is contaminated.
Cleaning the Cobalt AVL GlideScope Cobalt AVL System ® Disinfecting the GlideScope Cobalt AVL Video Baton To disinfect use any of the chemicals listed in Table 3 and do the following: Ensure the equipment is clean (see Cleaning Section for video baton).
Cleaning the Cobalt AVL GlideScope Cobalt AVL System ® Cleaning and Disinfecting the GlideRite The Stylet is a nonsterile, reusable device which requires cleaning and High Rigid Stylet Level Disinfection as defined in the risk analysis—Table 2 on page 36.
GlideScope Cobalt AVL Warranties Verathon Medical includes a one-year warranty when you buy a GlideScope Cobalt AVL System. You can also buy a Premium Customer Care Warranty that can extend your warranty for up to five (5) years from date of purchase.
Page 70
Cobalt AVL Warranties GlideScope Cobalt AVL System ® What is covered? Warranty coverage is extended to the GlideScope Cobalt AVL System: • Video Monitor including Display Connector Cable • GlideScope Cobalt AVL Video Baton Additional video batons purchased either singularly or as a part of a system must be warranted separately.
Symbol Directory GlideScope Cobalt AVL System ® Symbol Directory Symbol Meaning Type BF equipment Class II Electrical equipment CE marking in accordance with the Medical Device Directive ( for Sterile Devices) 0413 Canadian Standards Association (CSA) mark of certification to applicable standards for electromedical...
Cobalt AVL System ® GlideScope Cobalt AVL Product Specifications Length of flexible baton ......66 mm Cobalt AVL Video Baton 1-2 Height at camera ..........6 mm Width at camera ..........7 mm Video cable length ........204 cm Weight ..............180 g Length of flexible baton ......105 mm Cobalt AVL Video Baton 3-4 Height at camera ..........11 mm...
Page 73
Product Specifications GlideScope Cobalt AVL System ® TFT Color, 6.4 in (diagonal), VGA 640 x 480 Cobalt AVL Monitor Monitor ..............6.4 in Height .............190 mm Width ..............225 mm Depth ..............80 mm Weight ..............1.0 kg Handle Length ..........82 mm GlideRite Rigid Stylet ®...
Product Specifications GlideScope Cobalt AVL System ® GlideScope Specifications, Standards, and Approvals General Specifications Classification: Electrical Class II, Applied Part BF Line Voltage: Range: 100–240 VAC, 50 and 60 Hz Connect to a medical grade power supply DC Power Supply: 12V DC, 2.5A max...
Cobalt AVL Mobile Stand 0800-0410 Cobalt AVL IV Pole Mounting Kit 0810-0200 Universal Accessory Basket 0803-0104 Cobalt AVL Video Monitor 12V DC Power Adaptor 0400-0105 HDMI to DVI Cable, 6m 0600-0533 AC Power Cord 15 ft (4.5 m) – North America 0600-0244 AC Power Cord 2 ft (0.6 m) –...
Contact Information GlideScope Cobalt AVL System ® Contact Information To obtain additional information regarding your GlideScope Cobalt AVL System, please contact Verathon Medical Customer Care at: 20001 North Creek Parkway Corporate Headquarters Bothell, WA 98011 U.S.A. 800.331.2313 (US and Canada only)
Need help?
Do you have a question about the Cobalt AVL and is the answer not in the manual?
Questions and answers