2) Multiple batteries in parallel connection(Refer to Fig. 3): Each battery's voltage
must be equal to the Nominal DC Voltage of the unit.
3) Multiple batteries in series connection(Refer to Fig. 4): All batteries must be
equal in voltage and amp hour capacity. The sum of their voltages must be equal to the
nominal DC Voltage of the unit.
Step 4- Make sure to connect the polarity of battery side and the unit correctly.
Positive pole (Red) of battery to the positive terminal (+) of the unit.
Negative pole (Black) of battery to the negative terminal (-) of the uni
4.3 Connect to Solar Panel
CAUTION: Before connecting to PV modules, please install separately a DC circuit
breaker between inverter and PV modules.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use
appropriate cable for PV module connection. To reduce risk of injury, please use the
proper recommended cable size as below.
Typical Amperage
50A
Step 1- Connect one cable to the positive (+) pole of solar panel and solar charger
positive (+) terminal.
Step 2- Connect the other cable to the negative (-) pole of solar panel and solar charger
negative (-) terminal.
SCC SKY INVERTER User Manual
Fig. 3
Fig. 4
Gauge
8 AWG
Solar Panel Connection
12V
24V
4
Torque Value
1.4~1.6 Nm