5.4 LCD Setting

After pressing and holding "ENTER" button for 3 seconds, the unit will enter setting mode. Press
''UP/DOWN'' button to select setting programs. And then, press "ENTER" button to confirm the selection
or "ESC" button to exit.
If there is no button action during 60 seconds, setting mode will exit to normal display mode.
During shutdown process, the setting information can be stored in MCU, and it will be read out during
next start up.
Program
Description
AC input
voltage
00
range
selection
AC charging
01
current
selection
Low DC
cut-off
02
voltage
setting
AC output
rating
03
voltage
selection
Output
source
04
priority
(utility or
solar first)
SCC SKY INVERTER User Manual
Wide(default)
If selected, acceptable AC input
voltage range will be within
90~280Vac.
20A (default)
9.8V (default)
1000VA model: setting range
8.7~12.0Vdc, 0.1V /time.
230V (default)
utility first(default)
Utility will provide power to the
loads as first priority.
Solar and battery energy will
Selectable option
If selected, acceptable AC input
voltage range will be within
170~280Vac.
2000VA model: setting range
17.5~24.0Vdc, 0.1V /time.
220V
Solar energy provide power to the
loads as first priority.
If solar energy is not sufficient to
8
Narrow
10A
19.6V(default)
240V
Solar first