Technical data

18
Display
Regulation
Dosing
Measurement of pH value
Measuring range pH
Cable lenght sensors
Max. pump delivery pressure
Max. pump flow rate
Electrical connection
Power consumption
Protection class of the device
Operating temperature
Dimension of the controller
Weight of the controller

Declaration of Conformity

19
We,
hereby declare that the models of the product named in the following that we bring into circulation meet the requirements of the indicated EC directive.
Product designation:
Product model:
Series no.:
EC directives:
Harmonizing standards used:
Date, manufacturer signature:
Signer's information:

Disposal instructions

20
Disposal of electrical and electronic household appliances in the European Union
All products marked with this symbol must not be disposed of with household waste after use. It is the user's
responsibility to dispose of this type of waste by taking it to a recycling centre suitable for the selective disposal
of electrical and electronic waste. The appropriate recycling and treatment of this waste contribute significantly
to the preservation of the environment and the health of users. For more information on collection points for this
type of waste, please contact the retailer from whom you purchased the product or your local council.
28
4.3" TFT colour touchscreen, 32bit Microprocessor, enhanced graphic acceleration
Adaptive proportional control
pH-Minus Liquid Domestic or pH-Plus Liquid
Single-rod sensor, BNC
0 – 10.0
2 m
1.5 bar
2.4 l/h
240 V~, 50/60 Hz
Controller max. 10 W / Dosing pump max. 8 W
IP 65
0 °C – 40 °C // 32 °F – 104 °F
315 x 210 x 94 mm (H x W x D)
Approx.: 1.7 kg
BAYROL Deutschland GmbH
Robert-Koch-Str. 4
82152 Planegg/Steinkirchen
Germany
Measurement, control, and dosing system for swimming pools
Automatic
pH
see type plate
EC – Low Voltage Directive (2014/35/EU)
EC – EMC Directive (2014/30/EU)
EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-3, EN61000-4-4, EN61000-4-5,
EN61000-4-6, EN61000-4-8, EN61000-4-11
01.03.2022
Lars Birckenstaedt, Managing Director BAYROL Group