Download Print this page

Philips DCM3100 Service Manual page 10

Hide thumbs Also See for DCM3100:

Advertisement

MEASUREMENT SETUP
Tuner FM
RF Generator
e.g. PM5326
Use a bandpass filter to eliminate hum (50Hz, 100Hz) and disturbance from the pilottone (19kHz, 38kHz).
Tuner AM (MW,LW)
DUT
RF Generator
e.g. PM5326
Frame aerial
e.g. 7122 707 89001
To avoid atmospheric interference all AM-measurements have to be carried out in a Faraday´s cage.
Use a bandpass filter (or at least a high pass filter with 250Hz) to eliminate hum (50Hz, 100Hz).
CD
Use Audio Signal Disc
SBC429 4822 397 30184
(replaces test disc 3)
DUT
L
R
All manuals and user guides at all-guides.com
Bandpass
DUT
250Hz-15kHz
e.g. 7122 707 48001
S/N and distortion meter
e.g. Sound Technology ST1700B
Bandpass
250Hz-15kHz
e.g. 7122 707 48001
S/N and distortion meter
e.g. Sound Technology ST1700B
S/N and distortion meter
e.g. Sound Technology ST1700B
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter
1-3
LF Voltmeter
e.g. PM2534
LF Voltmeter
e.g. PM2534
Recorder
Use Universal Test Cassette CrO2 SBC419 4822 397 30069
or Universal Test Cassette Fe
DUT
LF Generator
e.g. PM5110
SBC420 4822 397 30071
L
R
S/N and distortion mete
e.g. Sound Technology ST170
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter

Advertisement

loading