Overview of inhalation unit Plug-in mains supply unit MN 81200 Exhalation valve (light blue) Inhalation valve (dark blue) Mouthpiece Plug 12V DC Nebuliser head Rechargeable battery pack MN 81300 (depending on design) Baffle plate Function display (green, yellow) Sealing ring charging status Medicine chamber display (yellow)
Table of Contents Overview of inhalation unit Introduction and general information Starting the unit for the first time Hygiene: Cleaning, disinfection and sterilization Use of the rechargeable battery pack Trouble shooting Information on medicines Spare parts/consumables Optional accessories Service information and guarantee conditions Explanation of symbols Technical data and classification...
Dear Patient The multisonic® profi is a powerful ultrasonic neb- • Universal usage uliser for preventative and therapeutic deep inha- • Optimal penetration of tissues lation that reflects the latest scientific findings in this area. • High nebuliser performance and short However, the unit has not been designed for life- inhalation times saving emergency treatment.
Page 5
The basic package comprises the following components: 1 hand unit 1 nebuliser head 1 mouthpiece 1 sealing ring 1 baffle plate 1 inhalation valve 1 exhalation valve 1 metering aid 1 plug-in power supply unit 1 carrying case 1 set of Instructions for Use / Guarantee form...
Page 6
Points to note • The multisonic® profi can be used for nebulisa- • Clean the multisonic® profi carefully after each tion of all Inhalation solutions that are water- inhalation. based, including suspensions and natural thera- • Carry out the inhalation therapy as directed by py agents that are suitable for inhalation.
Page 7
Principle of function Air outflow Air inflow Exhalation valve Aerosol exit Inhalation valve Air and particles Baffle plate Aerosol Medicine ON/OFF-Button Ultrasound waves Ultrasonic generator (quartz)
Page 8
An example of periodic inhalation (mg) Average pulmonary deposition (NaCl 0.9%) Inhalation Pause in breathing Exhalation Breathing in slowly & deeply Hold breath Exhale deeply Depress Release pushbutton pushbutton Yellow LED is lit Duration of inhalation (secs)
Using the multisonic ® profi for the first time 230 VA Fig. 1 Fig. 2 Fig. 3 Remove the nebuliser head Pull the stopper out of the Plug the mains supply unit in- from the hand unit and place mains socket of the unit and to the mains socket outlet the hand unit on a flat surfa- plug in the 12V DC plug of the...
Page 10
Inhalation Fig. 1 Fig. 2 Fig. 3 Fill the medicine – dose and Ensure that the sealing ring Place the nebuliser head on quantity as directed by your sits correctly and that the baf- the hand unit and turn it in physician –...
Page 11
Exhalation valve Inhalation valve Inhalation valve Exhalation valve Fig. 4 Fig. 5 Fig. 6 Fit the mouthpiece, the inha- Lift up the hand unit and press Bring the hand unit up to your lation valve (dark blue) and the button “ON/OFF“ to turn mouth.
Page 12
Exhalation valve Air outflow Exhalation filter (optional) • After inhaling, hold your Air inflow breath for approximately 2 Dome seconds to allow the aerosol to deposit in the airways. Inhalation Aerosol Then breathe out through the filter exit mouthpiece. Continue the in- (optional) halation procedure until the unit switches off.
Page 13
Examples of various uses of the multisonic ® profi Fig. 1 Fig. 2 Fig. 3 Inhalation via the mouthpiece Inhalation via a mask Inhalation whilst lying down...
Page 14
The multisonic® profi switches off automatically at the end of the inhalation procedure, if the ON/OFF button is not pres- sed beforehand. This is indicat- ed through by the 2 function display lights going out. The unit is protected against run- ning dry and can then only be re-started if the 12 V DC plug is pulled out of the plug socket...
Cleaning and disinfection The inhalation unit and acces- be accelerated through the use sories must be cleaned before of warm air from a hairdryer being used for the first time, (at the lowest power setting). after each inhalation and after The unit must be disconnected storage for longer periods.
Page 16
holder should be disinfected It is recommended that users in in a plastic container that is Germany use one of the disin- suitable for use with disinfec- fectants listed in the current tants. They may be cleaned in DGHM* list. Preparations based a dishwasher or disinfected in on compounds that release a vaporizer.
Page 17
Disinfection in a vaporizer Fig. 1 Fig. 2 Fig. 3 Before using the vaporizer for the first time it is very important that you read the Instructions for Use. Remove the cover and the Place the hand unit with the Now place the central section central section of the vapori- opening facing downwards...
Page 18
Further hygiene measures In clinics: After sealing the socket with the stopper the hand unit can be disinfected / sterilized through immersion disinfec- tion, placing it in a chemical- thermal disinfector (60 °C for Fig. 4 Fig. 5 10 minutes) or in a gas sterili- Cover the central section and In the home: zer.
Page 19
Hygiene Table Designation Cleaning Disinfection Sterilization Multisonic Rinsing: Dish- Wiping & Immersion Chemical- Steam in Auto- Form- Plasma profi warm washer spray in disinfec- thermal 60ºC vaporizer claving aldehyde unit & running disinfec- tant solu- for 10 mins/ at 134 ºC consumables water tion...
Use of the rechargeable battery pack MN 81300 The following points must be charged (Fig. 1). After around LED 1 LED 2 observed when using the re- 3 seconds the LED will light up green yellow chargeable battery pack to en- continuously throughout the sure that you can use it with- entire charging period.
Page 21
The battery pack must be char- The battery pack has been spe- If the battery pack is not char- ged to a value > 20% (LED 3 lit) cially designed for use with ged correctly then its capacity before the nebuliser can be the multisonic inhalation unit.
Trouble shooting If the unit malfunctions then please check the fol- • Has an air bubble developed in the ultrasonic lowing: generator? If so, remove it carefully using a blunt instrument. • Is the unit connected to a power supply (plug-in mains supply unit or rechargeable battery pack)? •...
Recommendation Only use medicines that your The inhalation unit has been • The unit is not designed for physician has prescribed or tested with various medicines, emergency life-saving meas- recommended. including Atrovent®, Bero- ures. If you accidentally inhale medi- tec®, Berudual®, Brom-hexin- cines that are not suitable for Inhalat®,Cromoglicin-ratioph- Respiratory disorders that can...
Spare parts (consumables) The mouthpiece, nebuliser head, inhalation valve, exhalation valve, sealing ring, baffle plate and fil- ter holder will have to be changed depending on Nebuliser head Sealing ring set the number of inhalations per day and the degree of wear that results from cleaning and disinfection.
The unit is guaranteed for a peri- signature of its representative. Only original acces- od of 24 months from the date of purchase. sories may be used with the unit. Otto Schill Medizintechnik will not assume any liabi- lity if these conditions are not adhered to.
Explanation of symbols Meaning Symbol Direct voltage Alternating voltage Degree of protection against ingress of dust (X) IP XY and water (Y) Caution – observe documentation Type 1 usage component • Central positive (connection DC 12 V) Mark of conformity protected by law 0366 Do not use in humid environments Not to be worked on by unauthorized personnel...
Technical Data – multisonic ® profi Type MN 80180 Rechargeable battery pack MN 81300 Noise level: <15 dB (A) (noiseless) Input voltage: DC 12 V Nominal voltage: DC 12 V (plug-in power Output voltage: DC 12 V supply unit MN81200) Ah capacity: Nominal frequency: plug-in power supply...