Page 1
RB-RTExxx Ethernet router Operation manual Version 1.00 rb-rtexxx_g_en_100...
Page 2
RB-RTE AMiT, spol. s r. o. does not provide any warranty concerning the contents of this publication and reserves the right to change the documentation without obligation to inform anyone or authority about it. This document can be copied and redistributed under following conditions: 1.
RB-RTE History of revisions Document name: rb-rtexxx_g_en_100.pdf Revision Date Author of change Changes 02. 10. 2018 Pužman O. New document Related documentation Application Note AP0037 – Principles of using Ethernet network file: ap0037_en_xx.pdf – manufacturer of the MSC Q7-BT CPU core http://www.msc-technologies.eu/ Definition of used terms Train Communication Network –...
RB-RTE Introduction RB-RTExxx is a family of Ethernet TCN routers for rolling stock. Within the railway installation, the router provides connection between ETB and ECN Ethernet networks. Hereinafter in the text it will be referred to as router. Router contains the processor module with Intel Atom processor. Router is supplied without application.
RB-RTE Technical parameters Processor core Intel Atom E3815 1.46 GHz, 2 GB DDR3L, 4 GB eMMC FLASH 0 × to 1 × SATA Flash Number of modules 1 × mSATA Type and maximum number of SATA modules 2 × ETB Ethernet Number of connectors 2 ×...
Page 8
RB-RTE Recommended cabling Shielded cable Maximum cable length Connection point Connector HDMI, socket 0 × to 2 × Inputs / Quantity outputs Type Digital input / output 24 / 36 V DC (16.8 V to 45 V DC) Maximum input level for log. 0 4.5 V Minimum input level for log.
Page 9
RB-RTE Claims of EN Control unit is intended to operate up to 1 400 m above the sea level. 50155:2007 Control unit is designed to meet the Temperature Class TX. According to EN 61373:2010 standard, the control unit is classified in terms of vibrations into Category 1, Class B.
RB-RTE Possible variants RB-RTExxx router can be supplied in following variants. Name Digital Additional SATA Weight Weight SSD modules netto brutto 0 × RB-RTE040/00A 1.88 kg 2.25 kg Dimensions Fig. 1 – Router mechanical dimensions rb-rtexxx_g_en_100 10/35...
RB-RTE Recommended drawing symbol Following drawing symbol is recommended for this router. This drawing symbol is particular for RB-RTE040/00A. RB-RTE040/00A Fig. 2 – Recommended drawing symbol Block diagram Power supply ETH1 ETH2 ETH3 ETH4 Fig. 3 – RB-RTExxx block diagram 11/35 rb-rtexxx_g_en_100...
RB-RTE Product marking RB-RTExxx is fitted with producer type label. Location of labels, see Fig. 4. RB-RTE040/00A TYPE AB12345 HW REV MAC X2 00-00-00-00-00-00 MAC X3 00-00-00-00-00-00 MAC X4 00-00-00-00-00-00 MAC X5 00-00-00-00-00-00 16.8 to 50.4 V DC /0.6A POWER WEIGHT 1.88 kg TEST...
HW REV 00-00-00-00-00-00 MAC X2 00-00-00-00-00-00 MAC X3 00-00-00-00-00-00 MAC X4 00-00-00-00-00-00 MAC X5 16.8 to 50.4 V DC /0.6A POWER WEIGHT 1.88 kg OK-XX TEST HiPot-OK HiPot 24.09.2018 DATE Fig. 5 – Example of AMiT type label 13/35 rb-rtexxx_g_en_100...
RB-RTE Conformity assessment Providing, that router is correctly used, it complies with the requirements of Czech governmental decree NV117/2016. The conformity assessment has been carried out in accordance with harmonized standard EN 50121-3-2:2016. Tested in accordance Type of test Classification with standard EN 55016-2-1:2014 Specification for radio disturbance and...
RB-RTE Other tests Router has been assessed and approved for use in railway applications according to standards: Tested in accordance Type of test Result with standard Railway applications – Electronic EN 50155:2007 Complies equipment used on rolling stock Railway applications – Electromagnetic EN 50121-3-2:2016 Complies compatibility (EMC) –...
RB-RTE Processor modules Master processor module For master CPU, router uses a processor module with CPU Intel Atom. The core contains processor Intel® Atom™ E3815 2 GB DDR3L, 4 GB eMMC. Core For more details see the MSC Q7 module datasheet on manufacturer's website (see Related documentation).
RB-RTE Power supply Router power supply connector contains power supply inputs and two digital inputs / outputs (optional). Fig. 6 – Power supply and digital inputs / outputs connector Wiring Connector type WAGO769-666 of power Connector Signal Meaning supply DIO02 Digital input / output n.
RB-RTE Computer start up and shut down Router is turned on after connection of power supply to Vcc and GND terminals and activation by SB signal. 6.1.1 SB input is used Power ON In terms of data consistence, the unit's start-up is not critical and can be realized either by coincident connecting of power supply voltage to Vcc and SB terminals, or by connecting the voltage first to Vcc terminal and then to SB, or vice versa.
RB-RTE Incorrect shut down process is when the application doesn’t turn off during toff2. toff2 Fig. 8 – Computer start up and shut down 6.1.2 SB input is not used Power ON In terms of data consistence, the unit's start-up is not critical and can be realized either by coincident connecting of power supply voltage to Vcc and SB terminals, or by connecting the voltage first to Vcc terminal and then to SB, or vice versa.
RB-RTE Digital inputs / outputs Router can be equipped with two input / output pins, located on power supply connector. Both are galvanically separated from the router electronics. Pins can be used as an inputs or outputs with backward reading, bun never as input and output simultaneously.
RB-RTE Communication lines and peripherals Router contains following communication interfaces and peripherals: ▪ ETB Ethernet ▪ ECN Ethernet ▪ USB ▪ RS232 POWER SYS LEDS HDMI RS232 ETB ETHERNET ECN ETHERNET Fig. 11 – Location of peripherals on the bottom side Fig.
RB-RTE Ethernet Router is equipped with four independent Ethernet interfaces, each with its own MAC address. Interfaces on X2 and X3 connectors are used as connection to the ETB interfaces (Ethernet Train Backbone) which connects the vehicles through the coupling. When the router is switched off or the router application is not functional the X2 and X3 connectors are connected together effectively bypassing the non- operational router.
RB-RTE 8.1.3 Ethernet line state indication Indication of Ethernet line state is provided by two LEDs, located above M12 connector. Description of Status Description Ethernet is inactive Ethernet connected Blink Running communication No communication mSATA Router is equipped with one mSATA slot for additional memory module. The type of the installed mSATA module depends on the specific router variant.
RB-RTE Service peripherals Router contains following service peripherals: ▪ USB ▪ HDMI ▪ RS232 Service peripherals are used for device diagnostics and service interventions. Router is equipped with HDMI and USB service interfaces on front panel, and RS232 interfaces on the side. The interfaces are meant to be used by operator or by maintenance company for router setup and configuration.
Page 26
RB-RTE RS232 Router contains one RS232 interface on the side. The line is not galvanically separated, i.e. it is galvanically connected with router chassis. Line is used as service interface. Fig. 17 – RS232 connector Connector Connector type: D-sub DE-9, plug wiring Signal Signal type on connector...
RB-RTE 10 Indication elements 10.1 System LEDs Router state indication is provided by LED SYS located on front panel. Fig. 18 – System indication Meaning Status Meaning of LED Power is OFF, or system is not functional System is running No activity on mSATA module ON / BLINKS Reading or writing of data on mSATA module...
Sticker on the box contains following information: Item Description TYPE RB-RTE040/00A NETTO 1.88 kg BRUTTO 2.25 kg 1 pc Serial number – AMiT logo – QR code – CE sign RB-RTE040/00A TYPE 1.88 kg NETTO 2.25 kg BRUTTO 1 PC AB12345 Fig.
RB-RTE 12 Storing To prevent damage of the device, follow these rules. Product Product in original packaging must be stored under the conditions specified in in a package chapter Technical parameters. Product must not come into contact with water, oil or any other liquids that can damage the packaging. Box with the device can be stored in any position.
RB-RTE 13 Mounting, installation rules 13.1 Mounting instructions Router can be mounted in any position. To ensure proper cooling and access to router we recommend to keep a free space of minimum 70 mm sidewise and 100 mm from the surface of the heat sink. Alternatively, cooling can be arranged by additional means (fans, another measures).
RB-RTE 13.2 Cabling PE terminal of power supply connector must be connected with local installation earthing terminal. Minimum cross-section of supplying conductors must be at least 0.75 mm The cables or individual wires being connected to the device must be protected against mechanical stress.
RB-RTE 13.3 Mounting apertures Router is intended for mounting on the baseplate by means of four M5 bolts with low profile bolt heads. Four holes located in corners with diameter of 6 mm are used for mounting. Fig. 21 – Mounting apertures All dimensions are stated in mm.
RB-RTE 15 Maintenance According to cleanliness of the environment, where the product is installed, it is necessary to remove dust and dirt. Cleaning intervals have to be planned by the vehicle designer. According to the dust and dirt contamination level, there are cleaning ways as follows: Electronics Dust settles on product and its cooler, so thermal transmission between parts...
RB-RTE 16 Waste disposal Electronics The disposal of electronic equipment is subject to the regulations on handling disposal electrical waste. The device must not be disposed together with common public waste. It must be delivered to places specified for that purpose and recycled. Battery The equipment contains a lithium battery.
Need help?
Do you have a question about the RB-RTE Series and is the answer not in the manual?