Hole punch
Hide thumbs Also See for NURON NPU 100-22:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
3.4.2
Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it down for longer than three
seconds. The system does not detect a potential malfunction of the battery due to misuse, for example
battery dropped or pierced, external heat damage, etc.
Status
All LEDs show in sequence, followed by one (1)
LED showing constantly green.
All LEDs show in sequence, followed by one (1)
LED quick-flashing yellow.
All LEDs show in sequence, followed by one (1)
LED showing constantly red.
3.5
Items supplied
Knockout punch, operating instructions
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
4
Technical data
Rated voltage
Weight in accordance with EPTA Procedure 01
max. punching capacity
Storage temperature
Ambient temperature for operation
4.1
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise values
Sound power level (L
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
*2321735*
)
)
WA
)
pA
)
pA
2321735
Meaning
The battery can remain in use.
The check to ascertain the battery's state of health
did not complete. Repeat the procedure, or consult
Hilti Service.
If a connected product can still be used, the re-
maining battery capacity is below 50 %.
If a connected product can no longer be used, the
battery has reached the end of its useful life and
has to be replaced. Consult Hilti Service.
10 ga Steel
10 ga Stainless
steel
NPU 100-22
21.6 V
2.4 kg
102 mm
102 mm
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
77 dB(A)
2.5 dB(A)
66 dB(A)
1.5 dB(A)
English