12. Annex
12
Ann ex
12.1 Technical data USA/Canada version L15-L22 60 Hz
Technical data L15-L22 ; 60 Hz
Maximum operating pressure
Minimum operating pressure
Ambient temperature
Flow
After-cooler outlet temperature above ambient
temp.
Sound pressure level (to ISO 2151)
Nominal motor rating
Full-load current max. 200V / 230V
Full-load current max. 460V / 575 V
Motor protection type
Nominal speed
Nominal fan motor power
Recommended cable size
(200V/230V/460V/575V) @ 167°F
Recommended fuse size (200V230V/460V/575V)
Ventilating fan capacity
Cool air exhaust temperature above ambient temp.
max. allowable pressure drop in duct at ambient
Total oil volume
Approx. Oil carry over
Compressed air delivery connections
Weight (dry)
Dimensions L x W x T
L15
psi g
110
130
psi g
°F
cfm
91.5
85.5
°F
20
20
dB(A)
73
hp(kW)
20 (15)
Amps
63 / 56
Amps
30 / 23
rpm
AWG
4 / 4 / 8 / 10
Amps
80 / 70 / 35 / 30
cfm
°F
31
Pa
gal (Litres)
ppm
lbs (kg)
739 (335)
inch (mm)
L18
190
110
130
190
73.0
+ 33.8 / + 113
65.1
113.3
104.9
82.6
18
22
22
22
74
25 (18.5)
77 / 68
37 / 27
IP55, EPAct
3600
no separate fan motor
3 / 4 / 8 / 10
90 / 80 / 50 / 35
1943
42
200 @ 95 °F / 40 @ 113 °F
2.5 (9.5)
< 3
1 - 11 1/2 NPT
796 (361)
31 x 27.5 x 47.3 (787 x 698 x 1202)
L22
110
130
190
129.4
120.1
94.8
25
25
25
74
30 (22)
93 / 81
42 / 32
1 / 2 / 8 / 8
110 / 90 / 50 / 40
47
810 (367)
51