10. Service and maintenance
Cleaning:
Clean the filter mat by brushing or washing.
NOTICE
The filter pad may not be installed while wet or
moist!
b) Intake filter and outlet filter of switch cabinet
(only L15 RS - L22 RS):
* Open the louver grilles of the intake filter
(-4- Fig. 23) and of the outlet filter (-5- Fig. 23).
* Remove the filter pad.
* Insert the new filter pad into the louver grille.
Ensure that the smooth side (-A- Fig. 23) of the
filter pad faces the air intake side.
* Place the louver grille back onto the filter
housing.
Changing times for the filter mat
The operating modes and the quality of the suctioned
air (e.g. dust content) has a strong influence on the filter
service life.
The filter should be checked on a weekly basis,
eventually daily basis, for dust build-up. In these cases
the intervals between changes may be shorter.
10.14 Test period for pressure reservoir
and electrical installation
Pressure reservoir
As per the requirements of the 97/23/EC Pressure
Equipment Directive, a qualified person must inspect
the pressure reservoir from inside every five years.
As per the requirements of the 97/23/EC Pressure
Equipment Directive, an appointed body must perform a
strength test on the pressure reservoir after ten years.
Electrical installation
After four years, or after each intervention, the electric
installation must be tested by an electrician.
Should stricter inspection intervals apply in your
country, these must be observed.
48
10.15 Maintenance notes and lubricant
recommendations for stationary
compressors
Lubricant recommendations
Please note that proper lubrication can significantly
increase the lifespan of your compressor system.
In accordance with valid accident prevention
regulations, lubricating oils should be used whose
characteristics correspond to the expected operating
conditions.
Avoid mixing different lubricating oils, i.e. when
changing the oil type, first completely drain the old oil
from the oil circuit.
If seal temperatures are constantly above 195 °F divide
the oil change intervals given in Section 10.3
(Maintenance schedule) by half.
The exact oil change schedule according to the actual
operating conditions should be set by performing oil
tests.
Material Safety Data Sheets (MSDS) are available for
all Gardner Denver lubricants from your authorized
Gardner Denver distributor or by calling Gardner
Denver-USA at (937) 498-2500.
Use the following oil type:
AEON 9000SP - Synthetic
For further information, please contact your local
Gardner Denver Distributor.