TECHNICAL CHARACTERISTICS (under 20ºC / 50% RH / 1013 mBar conditions)
Power supply / Consumption
Resolution
Measurement Range
Repeatability
Time of response
Temperature range
Pressure range
Pressure coefficient
Enclosure
Relative humidity range
Maximum zero change
(+20 ºC to +40 ºC)
Output linearity
Output drift
Output impedance
Expected operation life
Backlit LCD Display
Storage time (months)
Storage temperature
Coverage area (m
2
) Approx
Installation height
-from floor- (cm)
Measurements (mm) Weight
(gr) Approx
DURAN ELECTRONICA CALIBRATES ONE BY ONE ALL DETECTORS USING CALIBRATION GAS
SONDELTOX
4-20mA detectors for toxic gases & O 2
SONDELTOX are 4-20mA detectors using electrochemical sensors for the detection of toxic
gases & O 2 . They are compatible with EUROSONDELCO and SIEMENS CC62P (using interface)
and with any other system provided of 4-20mA standard input.
Sondeltox for oxygen provided of backlit LCD display is available.
Available for these gases; Carbon monoxide (CO), Nitrogen dioxide (NO2), Sulphur dioxide
(SO 2 ), Nitrogen monoxide (NO), Clorhydric acid (HCl), Hydrogen sulphide (H 2 S), Chlorine (CL 2 ),
Oxygen (O 2 ).
CO
0-50, 0-100, 0-200, 0-300*, 0-500, 0-1000, 0-2000
NO
0-5, 0-10, 0-20*, 0-30, 0-50, 0-100, 0-200, 0-300
2
SO
0-10, 0-20, 0-30, 0-50, 0-100, 0-200*
2
NO
0-20, 0-30, 0-50, 0-100, 0-200*, 0-300
HCl
0-10, 0-20, 0-50, 0-100, 0-200*
H
S
0-5, 0-10, 0-20, 0-30, 0-50, 0-100, 0-200*, 0-300
2
Cl
0-5, 0-10, 0-20, 0-30, 0-50, 0-100, 0-200*
2
O
0-25 (in %)
2
H
0-200, 0-300, 0-500, 0-1000, 0-2000, 0-20.000, 0-50.000
2
* Bottom of scale for EUROSONDELCO and SIEMENS CC62P.
CO
SO
NO
2
2
0.1 ppm
0,5 ppm
0.1 ppm
0-2000ppm
0-300ppm
0-200ppm
2% F.S.
1% F.S.
2% F.S.
T90<35 s
T90<30 s
T90<15 s
0,020 ±
0,008%
without data
without data
signal/mBar
0.2ppm
9ppm
0.1ppm
<5% / year
<2% / month
<2% / month
4MΩ
4MΩ
4MΩ
3 years on air
2 years on air
2 years on air
6
6
6
300
200
200
170-200
100
30/40
VERIFY THE ZEROING AT LEAST ONCE IN A YEAR
MEASUREMENT RANGE (in ppm)
NO
HCl
From 10 to 35V DC / 21mA max.
0.5 ppm
0.5 ppm
0-300pmm
0-200ppm
2% F.S.
2% F.S.
T90<120 s
T90<10 s
(typical 100)
–20ºC to +50ºC
Atmospheric ± 10%
0.016%
without data
signal/mBar
signal/mBar
IP65
From 15 to 90% without condensation
9ppm
1,5 ppm
Linear in full range
<2% / month
<2% / month
<2%/ month
4MΩ
4MΩ
3 years on air
2 years on air
2 years on air
6
6
0-20ºC
150
200
100
100
125 x 150 x 63 - 300
MODEL WITH DISPLAY
H
S
O
2
2
0.25 ppm
0.1%
0.1 ppm
0-300ppm
0-25%
0-200ppm
1% F.S.
1% F.S.
2% F.S.
T90<35 s
T90<15 s
T90<60 s
0,008 ±
0.02%
0.002%
without data
signal/mBar
2ppm
9ppm
0.2ppm
<5% / year
<2% / month
4MΩ
15MΩ
2 years at 20% O 2
2 years on air
Optional
6
2
150
200
100
170-200
-
-
-
-
-
-
-
Yes
-
Cl
H
2
2
2 ppm
0-200 ppm
2% F.S.
T90<30 s
0,009 ±
0.003%
signal/mBar
10ppm
<2% / month
4MΩ
4MΩ
2 years on air
6
6
100
100
30/40 cm
100
from ceiling
Need help?
Do you have a question about the SONDELTOX and is the answer not in the manual?
Questions and answers