Page 1
We thank you very much for choosing our item. Now we would like to invite you to read carefully the following instructions before installing the product in order to use all its capacities. DIRVE K LOW CONSUMPTION IR OUTDOOR DUAL SENSOR MANUAL VERSION 0.5 The above symbol guarantees that the item complies with EU norms (EUROPEAN COMMUNITY) on devices that can generate interferences.
INSTALLATION SUGGESTIONS DIRVE K sensor can be fixed at heights between 50 and 250 cm, on vertical surfaces, walls or posts, using the anchor clamp and protection (item STAK). Obviously the...
Page 3
FIG.1 Prospectic view of covered area It is possible to orientate the detecting units in opposite directions horizontally, in order to prevent triggering an alarm if only one sensor detects movement. Only the crossing of both covered areas of the two detection zones will be considered an alarm. This mode is useful on balconies, terrazzos or corridors, where movement in only one direction is unavoidable.
Page 4
Due to the detecting units feature of being able to rotate on all axes, it is also possible to place the sensor on a slanting wall upwards without using further clamps, however detection from lower beams should be lost. Reducing the mounting height can compensate for this loss.
Page 5
This manual can be modified without any warning...
Page 6
O-RING MOUNTING DIRVE K is provided with 5 silicon O-RINGS to be mounted on the sensor for a good weather protection. The O-RINGS are in different colors (black and red). It is mandatory to respect the position of the different colors, because they have different purpose and if they are scrambled it is not guaranteed a good weather protection.
FUNCTIONS SETUP: TAMPER OUTPUT ALL THE OUTPUTS ARE N.C. (NORMALLY CLOSED) FREE VOLTAGE CIONTACTS LOW BATTERY OUTPUT • CLOSED IN STAND-BY • OPEN WHEN ACTIVE ALARM OUTPUT JUMPERS Closed = tamper disabled Wall Tamper Open = tamper enabled Cover Tamper Closed = tamper disabled Open = tamper enabled Test Buzzer...
DIP-SWITCHES DIP1 Sensor Logic OFF = AND mode for the heads ON = OR mode for the heads DIP2 IR Sensitivity OFF = High sensitivity (indoor use) ON = Low sensitivity (outdoor use) DIP3 AND mode OFF = NORMAL AND selection Alarm is triggered by a detection that starts from any head (with DIP1 OFF)
TECHNICAL FEATURES POWER SUPPLY Battery 9V CONSUMPTION Stand-by < 15uA – ALARME < 10mA SIGNALLING 1 LED for upper head, 1 LED for lower head, 1 LED for alarm transmission ALARM INPUTS 2 sensible elements, with selectable OR/AND mode TEST Test function selectable by dip-switch with led display and buzzer WIRED OUTPUTS Alarm, Tamper, Low battery...
Need help?
Do you have a question about the DIRVE K and is the answer not in the manual?
Questions and answers