Mode Rest rict ion

Mode Rest rict ion Funct ion:
• When SW2- 1 is on, t he system mode lock is on. This will lock
t he mode to Heat , Cool, Dry or Fan. No but ton press can
change mode. All ot her cont rol funct ions are available such as
• Mode can st ill be changed wit h a wireless cont rol, anot her
wired cont rol, or a cent ral cont rol.
• When set t ing mode lock, have cont rol set to desired mode. Set
dipswitch SW2- 1 to ON. Disconnect and reconnect system
power.
Checking Parameters (only applies to some models):
• Press and hold TEMP+ for 10 seconds to check t he parameters.
The parameters will appear in t he middle of t he screen to
show indoor address (00- 15), Let ters will appear after decimal
display (AbCdEF). The det ailed parameters will show on t he top
• If t he cont rol is connected to mult iple indoor unit s, each indoor
unit can be viewed by pressing t he FAN but ton. Then use
TEMP+/ - to switch bet ween connected indoor unit s.