HORIZONTAL SIDEWALL VENTING

For applications where vertical venting is not possible, the
only approved method of horizontal venting is the use of an
auxiliary power vent. Approved power venters are Fields
Controls Model SWG-4Y or the appropriate Tjernlund GPAK
model. Follow all application and installation details provided
by the manufacturer of the power vent. This unit may be hori-
zontally vented using 4" (10.2 cm) diameter pipe with a mini-
mum length of 4.5 feet (1.37 m) and a maximum length of
34.5 feet (10.82 m) with up to 4 elbows.
FILTER PERFORMANCE
The airflow capacity data published in Blower Performance
Tables above, represents blower performance WITHOUT fil-
ters. To determine the approximate blower performance of
the system, apply the filter drop value for the filter being used
or select an appropriate value from the Table below.

FILTER PERFORMANCE - PRESSURE DROP INCHES W.C. AND (KPA)

Airflow Range
CFM
0 - 750
751 - 1000
1001 - 1250
1251 - 1500
1501 - 1750
1751 - 2000
2001 & Above

UNIT CLEARANCES TO COMBUSTIBLES

Top
Application
In.
Downflow
1
Downflow B-Vent
1
Horizontal
1
Horizontal B-Vent
1
1
Special floor base or air conditioning coil required for use on combustible floor.
2
Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket
and building joists, studs or framing.
Unitary Products Group
Minimum
Opening Size
Disposable
2
In W.C.
in
230
330
330
330
380
380
463
Left
Front
Rear
Side
In.
In.
In.
6
0
0
3
0
0
6
0
0
3
0
0
NOTE: The filter pressure drop values in Blower Perfor-
mance Tables are typical values for the type of filter listed and
should only be used as a guideline. Actual pressure drop rat-
ings for each filter type vary between filter manufacturer.

FILTER SIZES

Cabinet Size
A
B
C
* All filters must be high velocity cleanable type.
Filter Type
Washable Fiber
In W.C.
0.01
0.01
0.05
0.05
0.10
0.10
0.10
0.10
0.15
0.14
0.19
0.18
0.19
0.18
Right
Flue
Floor/
Side
Bottom
In.
In.
3
6
0
1
3
6
Combustible
0
1
Combustible
246801-CTG-C-0407
Top Return (in)
Top Return (cm)
(2) 14 x 20
(2) 14 x 20
(2) 14 x 20
Pleated
In W.C.
0.15
0.20
0.20
0.25
0.30
0.30
0.30
Closet
Alcove
1
Yes
Yes
1
1
Yes
Yes
1
No
Yes
No
Yes
(2) 35.6 x 50.8
(2) 35.6 x 50.8
(2) 35.6 x 50.8
Line
Attic
Contact
Yes
No
Yes
No
2
Yes
Yes
2
Yes
Yes
5