WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property
damage.
ͷ Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
ͷ WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
ͷ Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Hussong Mfg. Co., Inc.
LXL-22-MV
Report No: 21-739
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an
aftermarket,
permanently
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
DANGER
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
located,
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
Rev. 1, 4.20.2022
Starting Serial Number:
22 LX2200001 18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LXL-22-MV and is the answer not in the manual?

Questions and answers

Summary of Contents for kozy heat LXL-22-MV

  • Page 1 L A K E FI EL D- 22- MV INSTALLATION AND OPERATION MANUAL Model #LXL-22-MV Direct Vent Gas Stove English and French installation manuals are available through your local dealer. Visit our website www.kozyheat.com. Les manuels d’installation en français et en anglais sont disponibles chez votre détaillant local.
  • Page 3: Homeowner Reference Information

    Read this manual before installation or operating this appliance. Please retain this owner’s manual for future reference. CONGRATULATIONS! We welcome you as a new owner of a Kozy Heat gas fireplace. Kozy Heat products are designed with superior components and materials, and assembled by trained craftsmen who take pride in their work.
  • Page 5: Table Of Contents

    6.2 Venting Requirements ................21 6.4 Vent Installation ..................23 6.5 Class A Chimney/Masonry Chimney Conversion ......26 6.6 Coaxial to Co-Linear Chimney Conversion ........27 #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 2022...
  • Page 7: Introduction

    Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 8: Specifications

    The junction box in this appliance requires 120VAC, 60Hz, and 6 Amps. • Verify the household breaker is shut off prior to working on any electrical lines. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 9: Appliance Dimensions

    SECTION 2 SPECIFICATIONS Appliance Dimensions 2.3 Appliance Dimensions FIGURE 2.1 LXL-22-MV Dimensions #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 10: Safety Barrier Screen And Overlays

    Hussong Mfg. Co., Inc.’s barriers for this appliance. Refer to section 7.1, SAFETY BARRIER SCREEN AND OVERLAY INSTALLATION on page 28 for installation instructions. FIGURE 2.2 Safety Barrier and Overlay Dimensions #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 11: Framing

    • If the appliance is to be installed above floor level, a solid, continuous platform must be constructed below the appliance. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 12: Clearances To Combustibles

    (443mm) (365mm) ½ ” (38mm) 3” (76mm) 3” (76mm) ½ ” (38mm) 14-7/16” (443mm) 3” (76mm) 3” 3” (76mm) (76mm) FIGURE 3.1 Typical Installation Options #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 13: Rough-In Vent Termination

    Follow the vent pipe manufacturer’s installation instructions for vent installation. • Rigid pipe dimensions in FIGURE 3.2 reflect Simpson Duravent 4” x 6-5/8” coaxial pipe. Other manufacturers product dimensions may vary. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 14: Alcove Installation

    62-5/8” (1591mm) 52” (1321mm) 72” (1829mm) FIGURE 3.3 Traditional Alcove Framing FIGURE 3.4 Alcove Front Wall Framing #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 15: Masonry Application

    6” (152mm) ¾ ” (19mm) unlimited 35” (889mm) ½ ” (1029mm) ½ ” (546mm) 3” 44” (76mm) (1118mm) 35” (889mm) FIGURE 3.5 Masonry Application #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 16: Outdoor Covered Gas Stove Installation

    The width of the overhang to EACH side of the gas stove (C) must be 5’ or greater. FIGURE 3.6 Outdoor Covered Gas Stove Install - 1 #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 17 Minimum weatherproof overhang in front and sides OUTSIDE INSIDE Free standing structure (weatherproof enclosure) FIGURE 3.7 Outdoor Covered Installation Guide - 2 #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 18: Gas Line Connection

    • Run gas line into fireplace. The gas line should be run to the point of connection where the shut-off valve and flexible gas line will connect. See FIGURE 2.1, LXL-22-MV DIMENSIONS on page 9. • Do not run gas line in a manner that would obstruct the optional fan operation.
  • Page 19: Termination Locations

    Over 14/12 to 16/12 1.83 Over 16/12 to 18/12 2.13 Over 18/12 to 20/12 2.27 Over 20/12 to 21/12 2.44 FIGURE 5.1 Vertical Vent Cap Clearance #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 20: Minimum Termination Clearances

    VINYL SOFFIT, VINYL CEILING, AND VINYL OVERHANG DISCLAIMER: Clearances to heat resistant material (i.e. wood, metal). This does not include vinyl. Hussong Manufacturing Co., Inc. will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings, or vinyl ventilated/unventilated soffits. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 21: Venting

    TM-4HT TM-4RHT TM-4ST36 4DHT Metal Fab Adapter 4DDA must be used 4DST36 VDV-HC04 Olympia Chimney Supply, Inc. VDV-VC04 VDV-SNC0414 VDV-SNC0436 4DT-HC Selkirk 4DT-HCR 4DT-VC 4DT-ST36 #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 22 Insert restrictor plate into exhaust pipe with tabs pointing towards you if installing after venting is attached FIGURE 6.2 Baffle Restrictor Adjustments FIGURE 6.1 Restrictor Plate Installation #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 23: Vent Installation

    Natural Gas and Propane Installations (i) Minimum / Maximum Vertical Terminations: 36” (914mm) minimum vertical length / 50’ (15.24m) maximum vertical length + termination cap 50’ (15.24m) 36” (914mm) #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 24 DIAG. 2 NATURAL GAS & PROPANE HORIZONTAL TERMINATIONS (A) 90° Elbow (B) Termination Cap 24” (610mm) 24” (610mm) 12’ (3.66m) 8’ (2.44m) 48” (1219mm) 36” (914mm) #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 25 Vent termination must be within the shaded area in FIGURE 6.3. maximum venting allowed. 25’ (7.6m) maximum vertical rise + 25’ (7.6m) maximum horizontal run = 50’ (15.2m) of total length FIGURE 6.3 Combination Venting #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 26: Class A Chimney/Masonry Chimney Conversion

    90° elbow + retro connector + 10’ (3.05m) minimum length of 4” aluminum flexible pipe / 50’ (15.24m) maximum length of 4” aluminum flexible pipe + top adapter + termination #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 27: Coaxial To Co-Linear Chimney Conversion

    / 50’ (15.24m) maximum length of 3” x 3” aluminum flexible pipe + roof flashing + termination cap 24” (610mm) maximum horizontal pipe #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 28: Fireplace Setup

    To remove safety barrier screen: lift the screen up and out of slots. FIGURE 7. Glass Frame Assembly Removal and Installation FIGURE 7.1 Safety Barrier Screen Installation #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 29: Lx22-500 Log Set Installation

    Align log LX3 with the notch in the ash panel and place into position, as shown in FIGURE 7.3. FIGURE 7.3 Base Logs FIGURE 7.4 Completed Installation #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 30: Control Board Removal And Installation

    Turn the manual valve counterclockwise to the ON position. Verify proper log placement, operation of fireplace, and any electrical components. FIGURE 7.5 Control Board Removal and Installation #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 31: Electrical Information

    Attach gas valve connectors to the wall switch/thermostat wires, connect to top and bottom terminals marked TH and TP-TH on gas valve FIGURE 8.2 Wiring Schematic with Thermostat or Wall Switch Wiring #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 32: Lighting Instructions

    Turn off all electric power to the appliance if service is to be Push in gas control knob slightly and turn clockwise to“OFF”. performed. Close the door of the control enclosure. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 33: Flame Height And Heat Output Adjustment

    Refer to the lighting instructions on the previous page for lighting procedures and safety information. Gas control knob HI/LO pressure regulator knob FIGURE 9.1 Millivolt Gas Control Valve #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 34: Adjustment

    Turn the gas control knob to OFF. Tap (B) (0.41 - 0.87 kPa) (1.59 - 2.48 kPa) Manifold pressure tap Inlet pressure tap FIGURE 10.1 Pressure Check Taps #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 35: Burner Flame Adjustments

    Close the door of the control enclosure. Adjustable venturi lever Wing nut securing adjustable venturi lever FIGURE 10.4 Flame Appearance and Characteristics FIGURE 10.2 Adjustable Venturi Lever location #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 36 FIGURE 10.6 Baffle Restrictor Adjustments FIGURE 10.5 Flame Appearance and Characteristics for Restricting Vent #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 37 Tip the baffle against the firebox back wall, and secure with (3) screws previously removed. Reinstall all components previously removed. FIGURE 10.7 Vent Access and Restrictor Plate #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 38: Troubleshooting

    Install pilot shield. Pilot safety dropout Pilot flame is too high or too low. Clean pilot hood and adjust pilot flame for maximum flame impingement on thermopile. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 39 Blockage or leakage of the vent Check the vent pipe for leaks, and the vent cap for debris. Repair vent system pipe or remove debris from vent cap if necessary. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 40: Maintenance

    Inspect the condition of vent and vent terminal for sooting or obstruction and correct if present. • The flow of combustion and ventilation air must not be obstructed. #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 41: Burner And Pilot System

    It must de-energize the safety shutoff in no more than (30) seconds. FIGURE 12.2 Pilot and Burner Correct Flame Appearance FIGURE 12.1 Burner System #LXL-22-MV HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.1 4 . 2 0 . 2022...
  • Page 42: Replacement Parts List

    WARNING: This product can expose you to chemicals including Lead, which is [are] known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov. LXL-22-MV CONTROL BOARD AND PARTS LX22MV-770 Control Board - Natural Gas...
  • Page 43: Optional Fan Kit

    SECTION 14 OPTIONAL FAN KIT 14.0 LX22-028MV OPTIONAL FAN KIT For use with model # #LXL-22-MV WARNING: This product can expose you to chemicals including Ethylbenzene which is (are) known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov...
  • Page 45: Limited Lifetime Warranty

    • All parts and material except the items listed in the 30 day Kozy Heat gas appliance from the date of purchase to the original warranty and any exclusions or limitations that may apply. purchaser, that it is free of defects in materials and workmanship at *Hussong Mfg.