Download Print this page

Signode PSD-109 Quick Start Manual page 2

Hide thumbs Also See for PSD-109:

Advertisement

ENGINEERED PRODUCTS TECHNICAL INFORMATION RELEASE
(POWER STRAPPING MACHINE DIVISION)
DISPENSER GUARD INSTALLATION
PSD-109 & PSD-119 DISPENSERS:
1. Before installing the guard, follow your plant's lockout/tagout procedures for securing and
isolating all power sources to the dispenser.
2. Attach internal warning sign as shown on guard side of post. Subsequently, the guard will cover
sign.
3. Using two (2) 9/16" wrenches, loosen (DO NOT REMOVE) the hex head bolt.
Locknut
4. Slide guard into place and re-tighten the bolt.
Locknut
will be
positioned
inside the
guard
©2015 SIGNODE SPD 1824 07-29-15
TIR: 2015-409
(ESTIMATED INSTALLATION TIME - 15 MINUTES)
4" to 4-1/2"
Hex head bolt with
flat washer
Hex head
bolt with
flat washer
will be
positioned
outside
the guard
Page 2

Advertisement

loading

This manual is also suitable for:

Psd-119