TROUBLESHOOTING ..........................12 Thank you for purchasing this Goodway vapor-steam cleaner. We appreciate your business and look forward to serving you in the future. As with all Goodway products, you can be assured that the finest quality components and workmanship have gone into this machine.
GENERAL The GVC-72000 vapor-steam cleaner is the most powerful vapor steam-cleaner in its class. It melts away grease and grime, and can kill bacteria and other microorganisms when high temperature is applied for extended periods. Please review these instructions prior to installation and operation of this vapor- steam cleaner.
20. Do not change nozzle size. An incorrect nozzle could cause excessive pressure resulting in equipment damage and possible personal injury. 21. Use only Goodway specified replacement parts and attachments. 22. Keep objects, loose clothing, hair, body parts away from openings and moving parts.
Hose Connection Manifold A-1 Pressure Gauge (A-1) Hose Connection Manifold A-2 Pressure Gauge (A-2) Emergency Off Button Power On/Off Functions Control Panel 72kW Hose Connection Manifold Boiler Control Panel 10. Boiler Steam Drain Valve On/Off (See Pic.2 on next page) GVC-72000...
Page 6
5.6 P1 Service Function 5.3 Boiler Pump LED 5.7 Temperature Display 5.4 Boiler Heating LED 5.8 P2 Service Function Functions Control Panel (Pic.3): 4.1 Tank Full LED 4.3 Boiler Selector (36kW/72kW) 4.2 Continuous Water Fill On/Off 4.4 Steam Output Selector GVC-72000...
SET – UP Remove from packaging and inspect unit. Report any discrepancies to Goodway Technologies Corporation’s Customer Service at (800) 370-2855. Attach handle to the front of the unit using four included fasteners. Position this vapor-steam cleaner in the area it will be used.
OFF button 3 (Pic.1). The switch will remain in the off position until manually reset by turning the switch so that it pops back up! Reset ONLY after having removed the cause of malfunction. See the troubleshooting section! GVC-72000...
Page 9
6 bar again. Turn off the main power 8 (Pic 1). Dry all accessories and store them in a dry environment. Clean the machine with a cloth, warm water and if necessary use a neutral detergent. GVC-72000...
ATTENTION: Scheduled maintenance should be done every 6 to 12 months or more often if used very heavily and/or if the water is very hard. Make arrangements with Goodway for professional maintenance and assistance. Only trained persons are allowed to perform the below procedure! The amount of carbonates in the water (chalk, salts and other minerals) determine the hardness of the water you use with this machine.
Boiler Descaling: Chemical scale removal may be necessary depending on use and water quality, contact Goodway Technologies for recommendations. Inspect and replace the water filter as necessary: TECHNICAL INFORMATION Specifications Input Power: 86 amps, 480 V, 60 Hz AC, three phase (Maximum...
The pressure drops rapidly Remove scale from boiler as during operation. described in the maintenance section. The pressure rises rapidly and the pump The machine needs to be serviced. continues to fill the boiler. GVC-72000...
Need help?
Do you have a question about the GVC-72000 and is the answer not in the manual?
Questions and answers