Bu Check Flow [Zz]; Bu (Optical Block) Repair Guide - Sony BDP-BX37 Service Manual

Hide thumbs Also See for BDP-BX37:
Table of Contents

Advertisement

1-4-3. BU Check Flow [zz] ~

Optical Block Unit (BU) IOP check flow (zz) ~ [Before BU Replacement]
Press
Select [3] dIOP then press 'ENTER'

1-4-4. BU (Optical Block) Repair Guide

BDP 5G (BDP-S370) series component structure is as same as conventional DVD Players.
However BD player requires precise read out functions and also secure contents Protection
system.
Since above requirement, it is necessary to set/adjust BU data to EEPROM.
The following cases need Adjustments;
(1)Replace BU (MB is original)
(2)Replace MB (BU is original)
(3)Replace both BU and MB
•JIG Requirement
Digital camera (recommend with macro mode)
Barcode decoder (5GBUJIG) installed in JIG PC's
USB memory
ESD work bench
•Procedure (all cases)
Remarks:
The servo adjustment procedure will be carried out during OP data Writing.
There is no manual adjustment procedure. LD ON TIME history doesn't carry over.
Do not touch any optical block parts, Turn Table and during replacing. BD Laser diode
is very sensitive!
Before BU Replacement
Enter Service Mode
<OPEN/CLOSE>., <PLAY>,<STOP>
and plug in AC Power
Inside *Service Mode Menu
Select [8] Drive
Inside *Drive
Select [7] OP Check Menu
Inside *OP Check Menu
Specification dIOP
+ -
BD:
6mA
DVD, CD:
+ -
9mA
YES
AC Power OFF
Refer the diagram
BDP-BX37/S270/S370/S373/S470
NO
IOP out of specification need BU
replacement
Optical Block Unit (BU) replace
(Flowchart yy)