Page 4
The price of the ifm products has then to be paid for the respective device itself (hardware) and not for the firmware. For the latest information on the license agreement for your product please visit www.ifm.com...
Multicode Reader O2I5xx 2 Safety instructions • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
O2I5xx Multicode Reader 2.3 Cyber security ATTENTION Unprotected network environment: The unit does not include IT security measures according to IEC 62443. w Unauthorised read or write access to data is possible. w Unauthorised manipulation of the device function is possible. u Check and restrict access options to the device.
Multicode Reader O2I5xx 3 Intended use The device decodes labelled and directly marked 2D codes and 1D bar codes. 3.1 Application area The device safety is rated for use under the following operating conditions according to EN IEC 61010-2-201: • indoor use •...
• Data processing with function blocks and logical links in the unit • Integrated ifm mass storage device saves current configuration for easy device replacement. Optional storage of error images 4.2 Web front end The unit has a web front end via which the following information can be retrieved: •...
If an internal or external illumination unit is used, it will be switched on with each triggering. 4.3.1 External triggering For external triggering of image captures, different trigger modes can be used (Ò software manual at documentation.ifm.com): • Negative edge •...
O2I5xx Multicode Reader Output Standard External illumination Process interface OUT2 For applications via ifmVisionAssistant: Trigger output Selectable via com- mand code evaluation 0: code evaluation not successful 1: code evaluation successful When using the teach button: OUT2 not used Tab. 1: Standard configuration of the switching outputs The switching output switches as soon as one of the following device states has occurred: •...
2.1 Nm. u Use the laser markings to align the unit (Ò Aligning the unit and object / 13). Information about available accessories at www.ifm.com 5.1 Installation instructions Storage at high humidity can lead to fogging of the front glass after switch-on, which can affect the functioning of the unit.
O2I5xx Multicode Reader 5.2 Mounting with clamp Fig. 7: Installation using the mounting set E2D500 M4 screws threaded M4 holes (depth 7 mm) bracket clamp u Fasten the bracket to the threaded M4 holes of the unit using two M4 screws. Tightening torque max.
Multicode Reader O2I5xx 5.3 Mounting with dome illumination Fig. 8: Installation using the mounting set E2D501 M4 screws threaded M4 holes (depth 7 mm) bracket clamp dome illumination u Fasten the bracket to the threaded M4 holes of the unit using two M4 screws. Tightening torque max.
Page 14
O2I5xx Multicode Reader The service life of the laser markings is approx. 10,000 hours. u Activate the laser markings only briefly for alignment.
Multicode Reader O2I5xx 6 Electrical connection ATTENTION The unit must be connected by a qualified electrician. Protection class III (PC III) unit (IEC 61010-2-201 chap. 6.5.2.101.4). The electrical supply must - be provided only by PELV circuits (IEC 61010-2-201 chap. 3.111), - not exceed 35 V DC during operation, - not exceed 60 V DC in the event of a single fault and - not exceed the permitted operating voltage of the unit (see data sheet).
O2I5xx device notebook for parameter setting industrial PC for evaluation and triggering proximity switch voltage source DC 24 V Fig. 10: Wiring example of a trigger circuit An adapter cable (Y cable) is available for external trigger sensors: Ò Accessories at www.ifm.com.
The illumination unit is connected to switching output OUT2 of the unit. The illumination unit is active as long as OUT2 is in the state "high". An adapter cable (Y cable) is available for external illuminations: Ò Accessories at www.ifm.com.
To be able to make full use of the unit’s functions, the ifmVisionAssistant software is required for parameter setting. u Download the ifmVisionAssistant software via the download area of the unit: documentation.ifm.com The operation of the ifmVisionAssistant software is described in the software manual. Ò Software manual at documentation.ifm.com...
Configuration successfully saved flashes at 8 Hz flashes at 8 Hz Active mode for configuration transfer from ifm storage device via teach button flashes at 8 Hz Error: lock button is active flashes at 8 Hz flash at 8 Hz Error: configuration failed Tab. 2: Teach LEDs (green, yellow), laser markings...
Page 20
O2I5xx Multicode Reader Ethernet LED Power LED OUT1 LED OUT2 LED Description flashes at 2 Hz flashes at 2 Hz Unit signals correctable error. The error information can be read via Ethernet. running light ⇒ Unit booting. running light ⇐ Unit carrying out firmware update.
Multicode Reader O2I5xx 9 Set-up Error during set-up w The unit may cause errors if it is put into operation below 0 °C. u Put the unit into operation above 0 °C. w After being put into operation, the unit can be used below 0 °C. The possible ambient temperatures are specified in the data sheet.
– Preconfigured process interface and switching outputs. – Simple device settings possible via code generation in the teach app. • Transfer the configuration from the ifm storage device (Ò Replacing the unit / 26). The ifmVisionAssistant software and the software manual are available on the internet: www.ifm.com 10.1 Teach code with teach button...
Page 23
Multicode Reader O2I5xx u Open the Teach app and follow the instructions. u Carry out configuration: • Trigger source • Process interface • IP address • reset of the device and restoration of the factory settings. u Generate configuration code. u Read in the configuration code via the device (Ò...
O2I5xx Multicode Reader 11 Operation The following recommendations increase the recognition rate: u Place the object (3) in the field of view (2). u Remove other objects from the field of view. u For objects with shiny surface: • slightly tilt the device (1) or •...
Multicode Reader O2I5xx 12 Troubleshooting If the unit behaves unexpectedly or incorrectly: u Download and install the latest firmware and ifmVisionAssistant versions. Download at documentation.ifm.com. If the problems persist: u Contact the ifm support. Contact at www.ifm.com.
13.1 Replacing the unit When the unit is replaced, the saved configuration can be transferred to the new unit. The internal ifm mass storage device of the old unit is inserted in the new unit. The integrated ifm storage device has a data retention time of 3 years at a maximum storage temperature of 55 °C.