  • Page 1 KOINE 4/5 PLASTERING MACHINE Operating,maintenance,spare parts manual 3223425 R18 - 2018/09...
  • Page 2 IMER INTERNATIONAL S.p.A. INTONACATRICI IMER FIG. 1 ENGLISH ( 1 ) WHEELED FRAME ( 2 ) HOPPER ( 3 ) MIXING CHAMBER ( 4 ) WATER CIRCUIT ( 4a ) WATER PUMP ( 4b ) MICROMETRIC VALVE ( 4c ) FLOW METER...
  • Page 3 IMER INTERNATIONAL S.p.A. KOINE 4/5 application onto the walls. Dear Customer, compliments on your purchase of this IMER plaster mixer, the re- 5. OPERATION SAFETY - Before using the plastering machine, ensure that it is - WORKING IN SAFETY. To ensure complete safety, read all the instructions in this - Never insert parts of the body and/or tools in the hopper manual carefully.
  • Page 4: Mechanical Safety

    IMER INTERNATIONAL S.p.A. KOINE 4/5 7. MECHANICAL SAFETY The hazardous points on the IMER plastering machine are protected by means of suitable safety devices, which must remain motor cooling fan guard and the grille on the hopper to prevent contact with the cell wheel.
  • Page 5: Water Connection

    IMER INTERNATIONAL S.p.A. KOINE 4/5 10.2 WATER CONNECTION water pressure does not fall below 2.5 bar; otherwise activate the 20l/min. - 800l/min if using gypsum based materials (pump D 6-3). - 500l/min if using cement based materials (pump D 6-3).
  • Page 6: Operation

    IMER INTERNATIONAL S.p.A. KOINE 4/5 FIG.10 THERMAL CUTOUT PROTECTION: Regulate the water to obtain the required consistency. - The electric motors are protected against overload by thermal magnetic cutouts, the activation of which is displayed by illumination of the red lamp (ref.1h). In this case, after the ones are more suited to materials with a larger particle size.
  • Page 7 FIG.13 To insert the screw in the stator, use the lubricant spray available from IMER. Never use mineral oil or grease for screw assembly as this may damage the stator. Avoid all types of benzene. In the case of a power failure during operationclean the machine and pipelines immediately (see para.13).
  • Page 8: Maintenance

    Repairs to the electrical installation must be performed exclusively by specialised personnel. Use exclusively original IMER spare parts, which must not If using pipelines with a different diameter for cleaning, use a - If any guards are removed for repairs, ensure they are suitably sized sponge.
  • Page 9 IMER INTERNATIONAL S.p.A. KOINE 4/5...
  • Page 10 IMER INTERNATIONAL S.p.A. KOINE 4/5 INDICATOR LAMP TABLE...