Download Print this page

Haier HU062WAMNA Operation & Installation Manual page 35

Hide thumbs Also See for HU062WAMNA:

Advertisement

Operation instructions for controller
Zone 1 Compensation Temp. of Cooling
Zone 1 Compensation Temp. of Heating
Zone 2 Compensation Temp. of Cooling
Zone 2 Compensation Temp. of Heating
DHW Compensation Temp.
Swimming Pool Compensation Temp.
Note: Actual target temperature of system=Set target temperature of controller + Compensation temperature
③ System installation
Tap "SYSTEM INSTALLATION" icon in Picture 22 to enter the system control parameters setting interface. You can set
the operating parameters for the system.
Function
Control Mode of Zone1
Control Mode of Zone2
Control Mode of DHW
Control Mode of Pool
Zones Water Temp. Control Mode
Auxiliary Heat Source
Outdoor Temp. for (Heat to Cool)
Outdoor Temp. for (Cool to Heat)
DHW On Temp.
Ambient Temp. of Heating Off
△ T for Heating On
Outdoor Temp. for Heater On
Heater On Delay Time
Heater On △ T of Target Temp.
Heater Off △ T of Target Temp.
Tank Re-heat Temp.
△ T for Cooling On
Target Temp. of DHW IO Board
Target Temp. of Pool IO Board
Travel Time of Mixing Valve
Function
Main controller, Third party controller, IDU ambient Temp. sensor
Main controller, Third party controller, IDU ambient Temp. sensor
Main Controller, Third Party Controller
Main Controller, Third Party Controller
IDU Electric Heater, Boiler, IDU Electric Heater + Boiler
Parameter Range
Picture 25
Parameter Range
Direct, Auto curve, Set curve
0~30°C
0~30°C
30~55°C
5~35°C
0~15°C
-20~15°C
0~120min
-10~2°C
-8~0°C
-12~2°C
1~15°C
25~75°C
20~30°C
30s~90s
33
-15~15°C
-15~15°C
-15~15°C
-15~15°C
-15~15°C
-15~15°C
Default
0°C
0°C
0°C
0°C
0°C
0°C
Default
Main controller
Main controller
Main Controller
Main Controller
Direct
IDU electric
Heating
15°C
10°C
45°C
27°C
6°C
0°C
60min
-3°C
-1°C
-3°C
5°C
45°C
24°C
60s

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Hu102wamna