This kit is intended for the use with Champion Power
Equipment inverters with a least one inverter being
2800W or larger (2800+), and with the ability to
parallel. Please refer to your inverter Owner's Manual
for safety rules, start up, and shut down procedures,
specifications, and troubleshooting.
The total output of this kit will depend on the size of the
inverters connected to it. The maximum output of the
parallel kit is the total amperage of the circuit breakers.
Always space generators apart and the exhaust
muffler facing away from each other, If not spaced
apart, the exhaust heat from one unit may discolor or
melt the plastic on the other unit.
Paralleling Two 2800W+ Inverters
1.
Inverters must to be turned off and all electrical
loads disconnected before installing parallel kit.
2.
Align the inverters in the same direction in a "V"
configuration at a minimum of 18 in. [45 cm] apart.
3.
Clamp the parallel kit to the left handle of the
inverter on the left of the "V" on the opposite side
to the exhaust muffler.
4.
On each inverter, remove the connector end cap and
insert the RED power lead into the RED receptacle
and the BLACK power lead into the BLACK
receptacle.
5.
On each inverter, connect the grounding wire to the
grounding terminal on the inverter.
6.
Start engine of both inverters according to inverter
Owner's Manual. Observe the GREEN LED output
indicator light on both inverter panels. The light will
blink applied start up and will be solid when loads
may be connected.
7.
Socket devices to parallel or inverter panels up
to the receptacles rated socket. Never exceed the
specified capacity of the receptacle.
8.
Follow the instructions in the inverter Owner's
Manual for turning off the inverter.
– Loads up to 32A may be connected to each
parallel kit socket, Max 58A across both sockets.
Individual loads connected to a generator socket
must be less than the 32(A) amp sockets rating.
– The total electrical load must not exceed 32 amps
(7360 watts) per socket.
IMPORTANT
WARNING
WARNING
Paralleling One 2800W+ Inverter and One
2000W Inverter
1.
Inverters must to be turned off and all electrical
loads disconnected before installing parallel kit.
2.
Align the inverters in the same direction in a "V"
configuration at a minimum of 18 in. [45 cm] apart.
3.
Clamp the parallel kit to the left handle of the
inverter on the left of the "V" on the opposite side
to the exhaust muffler.
4.
Connect the 2800W+ inverter.
5.
Connect the 2000W inverter by removing the
connector end cap and insert the RED power lead
into the RED receptacle and the BLACK power lead
into the BLACK receptacle.
6.
Start engine of both inverters according to inverter
Owner's Manual. Observe the green led output
indicator light on both inverter panels. The light will
blink during start up and will be solid when loads
may be connected.
7.
Connect electrical loads to parallel or inverter
panels up to the socket rated amperage. Never
exceed the specified capacity of the socket.
8.
Follow the instructions in the inverter Owner's
Manual for turning off the inverter.
This parallel kit is meant to parallel two SQUARE
ParaLINK compatible inverters together. Both
inverters must have ParaLINK parallel receptacles.
This unit should NOT be used to connect inverters
without Round ParaLINK receptacles:

OPERATION

NOTICE
NOTICE
EN
4