Alternative anti-tip method:

If the anti-tip brackets cannot be connected securely, you must use the alternative method below.
In this method, you can use wooden girders to avoid the risk of tipping over.
It must be installed as illustrated in the figure below.
There must be no clearance between the product and the wooden girder.
Minimum section dimensions of the wooden girder must be 3"x4" (75 mm x 100 mm). Width of the girder must be
equal to the clearance where it will be installed.
An additional girder must be used if the niche depth is more than anticipated. The wooden girder must contact the
product with a maximum size of 2" (50.8 mm).
To determine the location for the wooden girder, mark it on the rear wall, select suitable screws and connect safely.
WARNING:
Number and features of the screws to be used for the wooden girder must be determined so that there is no safe
connection.