Widearea VER-1P Installation Manual

Vdsl loop extender and power supply

Advertisement

Quick Links

Widearea Telecommunication Technology Co., Ltd
nd
rd
Add: 2
,3
East Round Longtan Industry Garden 10#,Chengdu, Sichuan, China
Tel: (86)28 84207501
master@widearea.com.cn
E-mail:
VDSL Loop Extender
And Power Supply
(For VER- 1P)
Installation Manual
Version 1.1
Fax: (86)28 84209696
Please read this
document carefully
before installation!
Web Site: http://www.widearea.com.cn

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VER-1P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Widearea VER-1P

  • Page 1 VDSL Loop Extender And Power Supply (For VER- 1P) Installation Manual Version 1.1 Widearea Telecommunication Technology Co., Ltd Add: 2 East Round Longtan Industry Garden 10#,Chengdu, Sichuan, China Tel: (86)28 84207501 Fax: (86)28 84209696 master@widearea.com.cn E-mail:...
  • Page 2  All brand names and trademarks are the property of their respective owners. This publication may neither be reproduced in whole nor in part without the express written permission of WIDEAREA.
  • Page 3: Table Of Contents

    Physical structure 7 Installation Procedure 8 5.1 Unpack 8 5.2 Install the remote power supply 9 5.3 Install the VER 9 Troubleshooting 10 This publication may neither be reproduced in whole nor in part without the express written permission of WIDEAREA.
  • Page 4: General Description

    VDSL loop extender box and the extender card are as below:  VER-1P box: One box for 1 VER-1P embedded.  VER-1P: One port VDSL loop extender for one VDSL subscriber can be inserted into the extender’s box easily. Benefits ...
  • Page 5: Application

    Output voltage DC 116V Output current less than 20mA Output port AEC-B1P 1 port Support the extender model and AEC-B1P one VER-1P quantity Dimension(LWH) AEC-B1P 110 mm×50 mm×30 mm 3. Application 3.1. The actual lines connecting of equipment Switch Pots...
  • Page 6: Resistance And Distance Demand

    3.2. Resistance and distance demand The recommended installation conditions are as follows. (1)26 AWG twist pair Table 3 -The demand about resistance and distance: 20℃ loop resistance Distance demand Route (Ω) 348 ~522 3.6 ~ 6.0 1.2 ~1.8 87 ~ 435 1.0 ~5.0 0.3 ~ 1.5 L(L1+L2)
  • Page 7: Physical Structure

    Physical structure VER-1P Cable STATUS LED Ground terminal Figure 2 VER-1P Table 5 - Twist-pair connection description of VER-1P Twist-pair color Connection Blue/White Remote PWR Orange/White to DSLAM Green/White to Modem Brown/White Unused 4.2 AEC-B1P Figure 3 AEC-B1P Attention: Two-core power cord without plug: used for DC48V power input, no polarity.
  • Page 8: Installation Procedure

    5.3 Install the VER  Fix the VER-1P box in the junction cabinet or near about at the supplied point. Ground the box through the grounding screw in the bottom outside the box. Attention: Copper-core wire with no less than 2.5mm...
  • Page 9: Troubleshooting

     Connect the cable VER-1P: Connect the power line with blue/white pair wire,CO signal line with orange/white, CPE signal line with green/white pair wire. Attention: The power supply should not be turn on until the extender installation is finished.
  • Page 10 Table 7 - VDSL loop extender troubleshooting Problem description Problem reason Suggested resolution Power supply cable(L3) is not Correct the power connection or check connected properly cable STATUS LED is not lit Correct the connection of the input No Power is supplied from power cable of power supply(AEC) supply(AEC) power on the power supply(AEC)