Turning the pump casing to achieve a different position
If necessary, the pump casing can be turned to change the position of the pump outlet by 90°.
• The pump casing can only be mounted in the two positions indicated.
• Reassemble the pump in the reverse order.
– Tightening torque for all loosened screws: 3 Nm
NOTE
If the pump housing jams when it is removed and pushes against the impeller unit, this will dam-
age the impeller unit.
Position the pump vertically before removing the pump housing. This ensures that the weight
of the pump housing can no longer push against the impeller unit.
Carefully pull the motor block off the pump housing, ensuring that it is kept straight.
Proceed equally carefully during assembly.