VX7T Salt Chlorine Generator
Controls Bacteria and Algae in Swimming Pool and Spa Water
For Domestic Use.
A maximum of 96 000 L of water can be treated with one VX7T Salt Chlorine Generator.
Maximum daily output of hypochlorous acid equivalent to 0.48 kg/day output of free available chlorine.
For swimming pools, a range of 1-3 ppm of free available chlorine must be maintained. For spas, a range of 3-5
ppm of free available chlorine must be maintained.
READ THE LABEL AND OPERATING MANUAL BEFORE USING
KEEP OUT OF REACH OF CHILDREN
REGISTRATION NO. 31187 PEST CONTROL PRODUCT ACT
WARNING: Operating the VX7T Salt Chlorine Generator without water flow through the cell can cause a build-
up of flammable gas which can result in FIRE OR EXPLOSION.
WARNING: Do not use this device with bromide products.
NOTICE TO USER: This pest control product is to be used only in accordance with the directions on the label. It
is an offense under the Pest Control Products Act to use this product in a way that is inconsistent with the
directions on the label.
Fluidra Group Australia PTY LTD
219 Woodpark Road
Smithfield, NSW 2164
Australia
Public Enquiries:
RBF International Ltée
780, Rue Nobel
Saint-Jérôme (Québec) Canada J7Z 7A3
450 438-4416

Advertisement

Table of Contents

Troubleshooting

loading

Summary of Contents for fluidra Astralpool VX7T

  • Page 1 NOTICE TO USER: This pest control product is to be used only in accordance with the directions on the label. It is an offense under the Pest Control Products Act to use this product in a way that is inconsistent with the directions on the label. Fluidra Group Australia PTY LTD 219 Woodpark Road Smithfield, NSW 2164...
  • Page 2 This cell must only be used on this model of chlorine generating device. Read the Label andthe Installation and Operation Manual for the VX7T Salt Chlorine Generator before using. Fluidra Group Australia PTY LTD 219 Woodpark Road Smithfield, NSW 2164...
  • Page 3 SAVE THESE INSTRUCTIONS Listed to UL 1081 Standard for Safety for Swimming Pool Pumps, Filters, and Chlorinators; and CSA C22.2 No 218.1 Standard for Spas, Hot Tubs, and Associated Equipment Fluidra Group Australia PTY LTD 219 Woodpark Road Smithfield, NSW 2164 Australia Public Enquiries: RBF International Ltée...
  • Page 4 VX7T Salt C h l o r i n e G e n e r a t o r It is said that all life evolved from the sea and that salt water makes up 70% of our bodies, so it's little wonder we find salt water the most natural medium to swim in.
  • Page 5 Extended Operation Use m enu function to select extended operation and Salt Chlorine Generator your VX7T will automatically extend its operating hours to allow for additional filtration and sanitation during Mineral Salts The VX7T Salt Chlorine Generator is suitable for use with pool salt or AstralPool's unique AcquaTherape...
  • Page 6: Table Of Contents

    INDEX{TABLE OF CONTENTS) 0.0 Important Safety Warnings ..........................5-7 1.0 General Overview ................................8 1.1 Chlorinator Control Unit Installation........................8 1.2 Cell Installation…………..............................9 1.3 Pool Preparation ................................10 2.1 User Panel...............................11 2.2 Programming ..............................12 2.3 Chlorine Output ................................13 2.4 User Mode .............................................14 3.0 Warnings Display………………………………………………………………………………………………………………………….15 3.1 Chlorine O u t p u t Level .........................16 3.2 Safety Backwash ...............................
  • Page 7: Important Safety Warnings

    0.0 IMPORTANT SAFETY WARNINGS W hen installing and using this electrical equipment, basic safety precautions should always be followed, including the following: -READ AND FOLLOW ALL INSTRUCTIONS IN THIS M ANUAL. – To reduce the risk of injury, do not permit children to use this product. –...
  • Page 8 0.0 IMPORTANT SAFETY WARNINGS If additional chlorine is required due to heavy bather loads, use chlorine to maintain an appropriate chlorine residual in the w at e r. Do not add directly to skimmer as this may damage the cell. -Maintaining high salt and chlorine levels above recommended range contributes to accelerated corrosion of pool and s p a equipment.
  • Page 9 0.0 IMPORTANT SAFETY WARNINGS -For proper sanitation, spas must be completely drained periodically. The number of days between COMPLETE SPA DRAINAGE is equal to the volume of spa water in litres, divided by 10 times the maximum number of daily spa users. Refill spa with water and repeat DIRECTIONS FOR USE of the chlorinator.
  • Page 10: General Overview

    VX7T SALT CHLORINE GENERATOR 1.0 GENERAL OVERVIEW Congratulations! You have purchased a VX7T Salt Chlorine Generator. Please read the instructions carefully and your purchase will provide you with years of trouble free use. Your VX7T Salt Chlorine Generator works by converting some of the salt in your pool into chlorine which starts to destroy algae and bacteria in your pool water thereby sanitizing your pool.
  • Page 11 The chlorinator cell must be located last in the pipe work just prior to the return to the pool. If valves are installed between the chlorinator control unit and the pool outlet, it is essential that they cannot deadhead the pump. If the pressure in the cell exceeds 150kPa (22 psi) and/or the water temperature exceeds 40°C (104°F), the cell may fail.
  • Page 12: Pool Preparation

    in the cell—the posts fit into the corresponding color keyed sockets on the connector end of the cell housing. The cable is designed to come from below the cell. Make sure wing nuts are correctly tightened to ensure good contact. 1.3 POOL PREPARATION The chlorinator requires a minimum 3000 ppm of salt but the recommended level is 4000 ppm therefore add 4 kg (8.8 lbs) of salt for every 1000 L (265 gal) of water (a typical pool of around 50 000 L (13,210 gal) requires 200 kg (441 lbs) of salt).
  • Page 13 Once programmed, you will generally only use the User Mode and Chlorine Output control.
  • Page 14: Programming

    2.2 Programming Setting Current Time/Day Select POOL MODE Standby/Off (a) Press the CLOCK button. Press DAY to change the current day. (c) Press HOUR to move the Display cursor to the hour digits and then use the Up and Down arrows to the right of the display to change the current hour.
  • Page 15: User Mode

    (a) Increase/Decrease arrows for setting the chlorine output level of the chlorinator. The chlorinator output can be set from levels 1 through to 8. This level only applies to Pool Mode. When the Chlorinator is in Spa mode, the chlorine output will be at level 1.
  • Page 16: Warnings Display

    3.0 WARNINGS DISPLAY Apart from messages displayed on the User display, there are two warning indicators. (a) LOW SALT: This indicates that the concentration of salt has reduced within your pool. To rectify, add salt at approx. 50 kg (110 lbs) per 50000 L (13,333 gals) of water (see Salt level under section 3.5 below). (b) NO FLOW: This indicates that the Chlorinator thinks that there is no flow to the cells.
  • Page 17: Safety Backwash

    Programming Area Low Salt Timer No Flow Clock Warnings display Hour Min. Auto Pool Chlorine Output Mode Boost Standby/Off Safety Chlorine Output Mode Backwash Chlorine Output Control User Mode Your VX7T Salt Chlorine Generator will always attempt to adjust the output so that the actual output level matches set point level.
  • Page 18: Run Dry Safety Feature

    Press twice for two minute pump operation Press three times for three minute pump operation d. Press four times to turn pump off 4. After pump turns off turn the filter multiport valve to Rinse Press the Safety backwash button on the use panel once for a one minute rinse When pump turns off, move the multiport valve back to filter position Press the pool mode button to “Auto”...
  • Page 19: Stabilizer

    Summer You should set your Chlorinator to operate for 8 to 10 hours per day. Ideally, run it for 4-5 hours in the morning and 4-5 hours in the evening. extremely hot weather it may be necessary to extend the running time if you find that the free chlorine level is too low. Winter You should set your Chlorinator to operate for 6 to 8 hours per day.
  • Page 20: Cell Maintenance

    If the supply cord is damaged, it must be replaced by Astral or its service agent or a similarly qualified person in order to avoid a hazard. 4.1 Cell Maintenance Your VX7T Salt Chlorine Generator has an automatic cleaning feature that under normal conditions, will keep the cell plates clear of deposits of salt and calcium.
  • Page 21 Daily 30 - 100 ppm 30 - 100 ppm...
  • Page 22: Scheduled Chlorinator Maintenance

    4.2 Scheduled Chlorinator Maintenance Maintenance Schedule: Your new product incorporates moving parts and withstands high velocity water with chemicals in it. Some of these parts will wear in the normal course of use and require regular checks and maintenance. Performing these checks and maintenance will identify parts that have worn and require repair/replacement before further serious damage is sustained.
  • Page 23: Troubleshooting

    5.0 Troubleshooting Fault Indication Potential Cause Remedy No Flow Pump turned off/disconnected or valves Ensure valves/pump on closed Blue wire disconnected from cell Connect Blue sense wire to cell Low salt Salt level in pool has dropped too low See section 3.5 above Pool water temperature is low See section 3.5 above Cell has calcified...