Replacing The Power Supply Unit; Psu Removal - Nokia MetroSite Field Upgrade Manual

Edge base station
Hide thumbs Also See for MetroSite:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
3

Replacing the power supply unit

The power supply unit (PSU) must be replaced only if the MetroSite BTS
installation is being upgraded from a 1W TRX configuration. See Table 4 for the
correct type of PSU replacements for a 5W TRX installation.
Note
The PSU does not need replacing for 5W GSM to 5W GSM/EDGE field
upgrades.
Table 4.
Input voltage
AC 230 V
AC 110 V
DC +24 V
DC -48 V
3.1

PSU removal

WARNING
Make sure that the power is turned OFF at the main disconnect device before
working on the PSU.
DN00187365
© Nokia Corporation
Issue 2-0 en
Nokia Proprietary and Confidential
PSU types used in MetroSite base stations
1W TRX BTS
installations
VSAA
VSAB
-
VSDA
Draft
Replacing the power supply unit
5W TRX BTS
installations
HVSA
HVSB
HVSC
HVSD
21 (50)

Advertisement

Table of Contents
loading

Table of Contents