Advertisement

ViewPoint Professional Series
VPx Sensor User Manual
Document No. DV3412
September 24, 2021
Rev. Draft

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ViewPoint Professional Series and is the answer not in the manual?

Questions and answers

Lily Li
May 27, 2025

why the sensor is beeping

1 comments:
Mr. Anderson
May 27, 2025

The Mesalabs Professional Series sensor is beeping because it is in an alarm state. The audible and visual alarms are triggered to notify individuals of this condition.

This answer is automatically generated

Summary of Contents for Mesalabs ViewPoint Professional Series

  • Page 1 ViewPoint Professional Series VPx Sensor User Manual Document No. DV3412 September 24, 2021 Rev. Draft...
  • Page 2: Table Of Contents

    9.1.1 ViewPoint G5 Compatibility ....................18 9.1.2 CheckPoint G4 Compatibility ....................18 10.0 Accessory and Probe List ........................ 19 11.0 VPx Sensor Models .......................... 19 Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 3: Figures

    Table 6-3 VPx Sensor 4-20 ma, 5v, 10v and 30v Inputs ................15 Table 8-1 LCD Icon Legend .......................... 17 Table 9-1 Input and Accessory Type Part Numbers ..................19 Table 10-1 VPx Models ..........................19 Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 4: Introduction

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: This unit is not explosion proof and is not rated for intrinsically safe installations. Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 5: Fcc Notice

    20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 6: Industry Canada

    L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 7: Features

    3.2 Audio Visual Alarm VPx Sensor has local Audible Visual alarms to notify individuals of sensor alarm states even with no access to the Viewpoint software. Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 8: Input Types

    -1.0 to + 1.0 inches H20 /-.25 to +.25 / -.5 to +.5 Particle Count Utilizes 4-20 mA Sensor Output Leak Detection Detect water in critical areas Table 3-1 Input Types Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 9: Menus

    To get to the Min-Max screen, start at the Home screen, Press Result Step 1 Min Max Screen Table 4-1 Access Min Max Menu Procedure Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 10: Clear Min Max

    To access the “Diagnostics” screen, start at the Home screen: Press Result Step 1 Option Screen up to “Diagnostics” Step 2 Move Step 3 Diagnostics Screen Table 4-3 Access Diagnostics Screen Procedure Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 11: 900 Mhz Diagnostics Screen

    VPx Sensor User Manual 4-3 900 MHz Diagnostics Screen 4-4 Wi-Fi Diagnostics Screen Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 12: New Battery

    To replace the (3) 3.6V lithium batteries in the VPx sensor, press down on the two recessed areas on the rear plate of the sensor and pull back the back cover to open the unit. 5-1 VPx Sensor Top and Back View Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 13: Vpx Sensor Internal View (Back Cover Removed)

    “New Battery” Step 2 Move Step 3 New Battery Confirmation “Confirm” New Battery Step 4 Table 5-1 Reset Battery Level Display Procedure (LCD) Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 14: Ports

    RTD – black wire 1 & 2 RTD – black wire RTD – white wire RTD – white wire Table 6-2 VPx Sensor RTD Probe Pin Assignments Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 15: Specs

    Range: +5°C to 40°C and 10% RH to 90% RH Accuracy: ±0.5°C and ±3% RH 7.3 Power VPx sensor makes use of a 5V 1A AC/DC Wall Mount Adapter (TWA22 – Power Supply) Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 16: Lcd Icon Legend

    Battery 1/3 Battery Low A/C Power connected Home Settings Link broken Link connected Min Max Fast Transmit Memory 1/3 full Memory 2/3 full Memory full Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 17 Signal Quality (no signal) Signal Quality – Poor Signal Quality – Fair Signal Quality – Good Signal Quality – Best Table 8-1 LCD Icon Legend Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 18: Operation Compatibility

    Select “CheckPoint G4 Compatibility” mode when using the sensor with a CheckPoint radio network and when the sensor will be communicating with a CheckPoint AP. Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...
  • Page 19: Accessory And Probe List

    Table 10-1 Input and Accessory Type Part Numbers 11.0 VPx Sensor Models VPx Sensor Model Part Number ViewPoint Professional 900MHz Sensor DS-VP-PRO-900-S Table 10-1 VPx Models Tel: 303-565-2724 Mesa Labs, Inc. monitoring.mesalabs.c 12100 W. 6th Avenue techsupport@mesalabs.com Lakewood, CO 80228 USA...

This manual is also suitable for:

VpxDs-vp-pro-900-s52000000

Table of Contents