Download Print this page

Precautions & Recommendations - Vesta S24 User Manual

Gas restaurant ranges

Advertisement

4. Precautions & Recommendations
4.1 Transportation and Storage
During transportation, the machine should be carefully handled and do not put it upside
down to prevent from damaging to the shell and inside. The packaged machine should be
stored in a ventilated warehouse without corrosive gas. If it needs to be stored in open air
temporarily, measurement against raining is needed.
4.2 Notice for Installment
1.
Installation of this device should be operated by professional technicians.
2.
This device is suitable for area whose altitude is lower than 2000m. If it is higher than
this altitude, please contact the manufacturer.
3.
Connection of this device should conform to provisions of gas safety, installation and
usage.
4.
This device should be kept a minimum clearance of 10cm away from
non-combustible objects on both sides and 20cm at the back (e.g. walls, windows
etc.). Do not install it on flammable floor or other combustible objects.
5.
Consider the weight of the device, please install it on the floor.
6.
Level the device with a level gauge. The height can be adjusted by the adjustable
feet.
7.
The mounting position should be well-ventilated and with ventilation facilities, which
will ensure that all the burnt gases produced during combustion process are
completely exhausted.
8.
After installation, level the device and keep stable. Do not sway or tilt during
operation.
9.
A quick-acting switching-off gas valve should be installed upstream the device where
is easy to be reached before installation.
10. Make sure that the supply gas is the same as the gas that the device allows to use. If
not, please stop using.
11. Do not use gas that not applicable for this device as fuel. Neither does high pressure
regulating valve nor medium pressure regulating valve. (This device is applicable to
low pressure regulating valve only.)
12. Pipeline that connecting to the device should be connected with proper metal pipe to
ensure no leakage.
13. If the pipeline pressure is 10% higher or lower than the rated pressure, please install
a pressure regulator to adjust the gas pressure to reach the rated one.
14. After connecting the appliance to the gas system, check for leaks at joints and pipe
fittings; to do so, use soapy water or a specific leak detector (spray). "No Flaming
Test!"
15. Check the gas supply pressure after installation.
7