HP Scitex FB7600 Manual page 37

Table of Contents

Advertisement

Table 1-4
power consumption of the FB7600 system.
Figure 1-14
system.
A dedicated power outlet should be provided for the White Ink Backup
unit located in the BLSC cabinet (see
Note:
In case that the system is powered by a generator, electrical requirements are the
same as for the mains.
In countries where voltage is lower, a
used.
In countries where voltage is higher, a
be used
Important
It is the responsibility of the customer to contact a local authorized electrician to prepare
the site with the proper wiring, circuit breakers, fuses (and power transformer if
necessary), and then to connect the HP Scitex FB7600 system to the mains power outlet.
Unit
Printing
unit
UV system
(*) This is the measured average/nominal power consumption while using the default UV
power setting. In case a user changes the default setting, the nominal power
consumption may increase by up to 40%.
and
Table 1-5
on page 29 show the electrical requirements and
shows the recommended power connection of the FB7600
Table 1-4 Electrical Requirements
Connection type
5-wire connection,
380 - 480 V between
3 + N + G
phases, 50/60 (±3 Hz)
4-wire connection,
380 - 480 V between
3 + G
phases, 50/60 (±3 Hz)
Table 1-5 Power Consumption
Unit
Printing unit
UV system
Figure
1-14).
suitable step-up transformer
suitable step-down transformer
Voltage input
Nominal
Maximum
30 A, 17 kW
30 A, 17 kW
68 A(*), 25 kW
120 A, 40 kW
must be
must
CB Rating
Power Line Ø
3 x 40 A
6 AWG
3 x 160 A
1/0 AWG
29

Advertisement

Table of Contents
loading