s fix disruptions
k You can remedy minor faults on the device yourself. Before using
contact customer service for information on troubleshooting. This way you
avoid unnecessary costs.
WARNING
Risk of electric shock! Improper repairs
are dangerous.
Only qualified personnel may carry out repairs on the device.
▶
Only original spare parts may be used for repair of the device.
▶
If the power cord of this appliance is damaged, it must be replaced with a
▶
special cord available from the manufacturer or its service agent.
Error code / error indication / signal
Malfunction
E:20-60 lights up alternately.
E:30-00 lights up alternately.
E:31-00 lights up alternately.
E:34-00 lights up alternately.
E:32-00 lights up alternately
or water supply indicator
lights up.
Depending on the device version
1
Cause
The appliance has
detected a calcified
heating element.
Aquastop system is
activated.
Aquastop system is
activated.
Water flows continuously
into the device.
Water supply hose is
kinked.
Tap is closed.
Tap is clogged or calcified.
TroubleshootingNL
Troubleshooting
Descale the appliance.
1.
Use the appliance with the
2.
water softener.
1
1.
Close the tap.
Contact the "service
2.
department"→Page 58.
1.
Close the tap.
Contact the "service
2.
department"→Page 58.
Close the tap.
1.
Contact the "service
2.
department"→Page 58.
▶
Route the water inlet hose
without kinks.
Turn on the tap.
▶
Turn on the tap.
▶
The amount of water flowing
in when the tap is open is at
least 10 l/min.
43