1d barcode scanner 360 omnidirectional for linear codes (55 pages)
Summary of Contents for Hamlet HBCS-2D110W
Page 1
2D BARCODE SCANNER WIRELESS 2.4GHz + BLUETOOTH SCANNER FOR QR CODES AND LINEAR BARCODES USER MANUAL HBCS-2D110W www.hamletcom.com...
Page 2
This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. The complete CE declaration of conformity of the product can be obtained by contacting Hamlet at info@hamletcom.com.
Table of Contents 1. Operation Settings ..........................6 1.1 Use of Programming Barcode ....................6 1.2 Restore Factory Defaults ......................7 1.3 User Default Settings ........................ 7 2. Communication Interface ........................8 2.1 Selection of Communication Mode ..................8 2.1.1 Output Mode of Communication Port ................8 2.2 Serial Communication Interface ....................
Page 4
5.3 Good Read Beep for Programming Barcode ................24 5.5 Good Read LED/Beep ......................25 5.6 Data Output Encoding Format ....................25 5.7 Different Country Keyboard Settings ..................26 5.8 Virtual keyboard enable......................27 5.9 Chinese output shielding ......................30 5.10 Analog keypad ........................
1. Operation Settings The factory default settings of the WSM-QL1601 are designed to meet the direct use of users in most cases. You can also set the parameters by setting the code according to the actual use. 1.1 Use of Programming Barcode Scan "enter programming barcode"...
1.2 Restore Factory Defaults After reading this programming barcode, the current parameter setting will be lost and the factory default value will be restored. Factory default parameters and functions can be found in Appendix C. Restore Factory Defaults Note: Please use the "Restore Factory Defaults" function with caution. 1.3 User Default Settings In addition to the factory reset, users can save frequently used settings as user defaults.
2. Communication Interface The WSM-QL1601 scanning module provides a TTL-232 serial communication interface and a USB interface (optional function) for communication with the host. The reading data can be received through the communication interface. 2.1 Selection of Communication Mode The USB-HID mode is default for communication. Users can switch between communication port output modes by reading code settings (TTL-232 Serial Port Mode / Virtual Serial Port / USB-HID Mode).
USB Virtual Serial Port Mode HID & TTL Simultaneous Mode 2.2 Serial Communication Interface The serial communication interface is a common way to connect the scanning module to the host device. When the serial communication interface in running, the communication module must be completely matched with the host device to ensure smooth communication and correct content.
1200bps 4800bps **9600bps 14400bps 19200bps 38400bps 57600bps 115200bps 2.2.2 Parity Methods There are 3 alternative parity methods, as follows: **None...
ODD Parity Even Parity 2.3 Configuration of USB-HID Interface Related Parameter 2.3.1 Selection of HID Devices When the product is set as HID devices,it could be two different devices。Users can scan the following programming barcode to set. **HID-KBW HID-POS HID-POS acquire scan data After scanning and decoding a barcode, the device would send the following input message.
**1ms 10ms 2.3.3 Timeout Before HID Release After reading the following programming barcode, you can modify the timeout before the HID is released (that is, the timeout from valid message to release message). The timeout is from 1ms to 63ms. **1ms 10ms 2.3.4 Timeout After HID Release...
10ms 2.3.5 CapsLock Status Settings ** CapsLock-Off CapsLock-On 2.3.6 Leading Key Output Users can scan the following programming barcode to enable HID to output a preamble message before outputting each piece of data, which is convenient for client as to software development and positioning. The key value is Ctrl+Shift+r.
3. Scanning Mode 3.1 Manual Mode Manual mode is a default scanning module. In manual mode, press the trigger button, the scanning module starts shooting and reading. In the limited duration of "Decode Session Timeout". After successful reading, the scanning module will output the scanned content through the communication interface and stop reading, if you need to one more reading, you need to re-trigger the button.
1000ms 3000ms **5000ms 10000ms Infinite 3.2 Command Trigger Mode In the command trigger mode, the scanning module starts shooting and reading after receiving the trigger signal command sent by the host (that is, the bit 0 of the flag bit 0x0002 is written to "1"); within the limited time range of "decode session timeout"...
Trigger command response disable ** Trigger command response allowed 3.2.1 Decode Session Timeout For the single reading duration setting, please refer to 3.1.2 Decode Session Timeout Code to set. 3.3 Continuous Mode Continuous Mode is a way for the scanning module to continuously capture, scan and output information.
500ms **1000ms 3000ms 5000ms 3.3.2 Timeout between Decodes (Same Barcode) In order to avoid the same barcode being continuously scanned for multiple times in continuous mode, Timeout between Decodes (Same Barcode) is required for scanning module in this mode before enabling the same barcode.
Infinite Delay 500ms 1000ms 3000ms 5000ms 3.3.3 Decode Session Timeout For the decode session timeout, please refer to the programming barcode of Section 3.1.2 Decode Session Timeout. 3.3.4 Continuous mode key pause switch When "Continuous Mode Key Pause Support" is set, the continuous mode trigger can be suspended by pressing the key for the first time, and the continuous mode trigger can be started by pressing the key again;...
conditions do not occur, the scanning module will cycle in the above manner: the barcode is not scanned within a Decode Session Timeout, and the scanning module will automatically pause the reading and enter the monitoring state. In the sensing scanning module, the scanning module can also boot reading by pressing the trigger button, and continue to monitor the brightness of the surrounding environment after the reading succeeds in outputting the information or releasing the trigger button.
High Sensitivity Enhanced Sensitivity 3.4.5 Image Stabilization Timeout Image Stabilization Timeout refers to the period for which the scanning module that detects the scene change needs to wait for the image to stabilize before reading the code in the inductive scanning module. The settting range of image stabilization timeout is 0~25500 ms, and the step size is 100ms.
4. Filling Light 4.1 Fill Light There is a set of LEDs on the scanning module that are specially equipped for shooting, providing auxiliary fill light, illuminating the light beams on the reading targets, improving the adaptability of recognizing performance and weak ambient light. You can set it according to the actual use: FFill Light - ON when Photographing: The fill light lights up while shooting and goes out if there is no shooting.
Page 22
F Positioning Light - always OFF : the positioning light does not illuminate in any cases. **Positioning Light - ON when Photographing Positioning light -always ON when Photographing Positioning Light - always ON Positioning Light - always OFF...
5. Prompt Output 5.1 Buzzer Master Switch Scan the following programming barcode to turn on /off all of the beep sounds. Mute _ ON **Mute _ OFF 5.2 Buzzer Settings 5.2.1 Passive Buzzer Scan the following programming barcode to set the buzzer to passive and set the drive frequency of the passive buzzer.
Active Buzzer **High Level Low Level 5.3 Good Read Beep for Programming Barcode Scan the following programming barcodes to enable/disable the programming barcode beep ** Beep for Programming Barcode_ON Beep for Programming Barcode _OFF 5.4 Startup Beep When the scanning module is on after power on, the scanning module can output or turn off the startup beep according to the setting requirements.
5.5 Good Read LED/Beep After the scanning module is successfully scan the codes, BEEP and DLED prompt signals are output through the 12pin external interface by default, and the external passive buzzer and LED are used for prompting. These signals can be turned off if the user requires to do so. ** Good Read LED_ON Good Read LED_OFF **Good Read Beep_ON...
so that the host can output Chinese data according to the specified encoding format. Note: GBK format is used for Text., UNICODE format is used for Word and input box of common chat tool. The Original Data output is used to encrypt the serial output of the data. **GBK UTF8 Original Data...
French Germany Hungary Italy Japan Spain Turkey Q Turkey F Mexico (Latin America) 5.8 Virtual keyboard enable In order to apply it in more regional application environments, the standard/virtual keyboard output settings can be made by reading the following programming barcodes. But that will cause a certain loss in output efficiency.
Page 28
**Standard Keyboard Virtual Keyboard 1. Virtual keyboard output mode In order to adapt to different application scenarios, the virtual keyboard has two different output modes for control characters less than 0x20, and users can switch by scanning the following setting codes. ** Control character output off Ctrl Mode Alt Mode...
Page 29
Enter "A"-press key A; Enter "Ctrl I"-since the data of 0x09 corresponds to the control function key "I", the virtual keyboard would hold down Ctrl, then press the I key, and finally release the Ctrl key and the I key at the same time; Enter "F"-press key F.
**Chinese output shielding-OFF Chinese output shielding-ON 5.10 Analog keypad 5.10.1 Output of numeric function of keypad If this function is not turned on, all outputs would be output according to the corresponding key value of the large keyboard. After this function is turned on, only the numbers "0~9" in the decoded data obtained by the reading module are output according to the key values corresponding to the small keyboard, and the rest are output according to the key values corresponding to the large keyboard.
Keypad Operator Output-On ** Keypad Operator Output-Off 5.11 Image Mirroring Mode When there is mirror flip in image, you can boot the mirror flip mode by reading the following programming barcodes. Image Mirror Flip _ ON ** Image Mirror Flip_ OFF Note: In the mirror flip mode, only the barcode of the mirror flip can be recognized.
** Invoicing Mode Enable Invoicing Mode Disable After the invoice mode is opened, you can select the invoicing mode by reading the following setting codes. ** Local Invoicing Mode Online Invoicing Mode It should be noted that when the user uses the online billing mode, the module must be switched to the HID-POS output mode only and used in combination with the WSM billing assistant.
WriteDeviceID:SN:xxxx;MID:xxxx;FID:xxxx. (Can be changed according to requirements) The return value of the write ID instruction is: The same as that of the write ID instruction Read ID format: ReadDeviceID. Return: SN:xxxx;MID:xxxx;FID:xxxx. For example: write device ID information for device: SN: 20200508; MID: WSM1605; FID: WSM 2020., and read that device ID by command Write ID: Serial port sending: WriteDeviceID:SN:20200508;MID:WSM1605;FID:WSM2020.
6. Prefix & Suffix In practical applications, in order to facilitate data differentiation processing, sometimes it is necessary for the read data to be edited before being output. Prefix & Suffix include: ◆ Prefix ◆ Suffix u Decode data segment interception u Code ID u Decoding failure feature output information (RF Information) u Tails...
Appendix F for the hexadecimal conversion table of character values. 6.2 Suffix Suffix is a string of strings defined by the user before the data is decoded. The user can add and modify the prefixes by reading the following programming barcodes. Enable Sufixes **Disable Sufixes Scan the following programming barcode, with the programming barcode of "Digit Barcodes"...
Restore Default Code ID 6.3.2 Modify Code ID Users can modify the Code ID corresponding to each barcode by reading the following programming barcodes. Modify EAN13 Code ID Modify EAN8 Code ID Modify UPC-A Code ID Modify UPC-E0 Code ID Modify UPC-E1 Code ID Modify Code 128 Code ID Modify Code 39 Code ID...
Page 39
Modify Codabar Code ID Modify Interleaved 2 of 5 Code ID Modify Industrial 25 Code ID Modify Matrix 2 of 5 Code ID Modify Code11 Code ID Modify MSI Code ID Modify RSS Code ID Modify RSS-Limited Code ID Modify RSS-Expanded Code ID Modify QR Code Code ID...
Modify Data Matrix Code ID Modify PDF417 Code ID Modify Mico QR Code ID Modify Chinese Sensible(HanXin) Code ID 6.4 Tail Tail OFF **CR Tail (0x0D) TAB Tail (0x09) CRLF Tail (0x0D 0x0A) 6.5 Data Character 6.5.1 Date Character Interception This function is used in scenarios where the user needs to output partial decoded information.
** Transmit all Data Tansmit the Start Data Tansmit the END Data Tansmit the Center Data 6.5.2 Modify the Length for Data The user can modify the length of the Start Data and the length of the End Data by reading the following programming barcodes, combined with the programming barcodes of "Digit Barcodes"...
Scan the following programming barcode, combined with the programming barcode of "Digit Barcodes" and "save", you can modify the RF information by yourself, and two hexadecimal values is for a prefix character, there are 15 characters at most. Refer to Appendix F for the character-to-hexadecimal conversion table.
1) Read the setting code of "GS character replacement enable"; 2) Read the setting code of "GS replacement character modification"; 3) The characters replaced by GS are represented by two hexadecimal values, and the characters correspond to the hexadecimal conversion table refer to Appendix F 4) Read the "Save"...
7. Quick Operation 7.1 Fast POS Mode POS Mode features: ◆ Scan mode: Command Trigger Mode u Communication port: Serial Port u Startup Beep OFF ◆ Tail OFF Users can quickly configure the reading device to work in POS Mode by reading the following programming barcode.
8. Symbologies 8.1 Global Shortcuts 8.1.1 Global Operations The user can globally enable/Disable and enable the default reading type for all supported code systems by reading the following programming barcodes. After reading all types of code systems, only the programming barcode is enabled. Enable All Symbologies Disable All Symbologies ** Enable Default Symbologies...
** Enhancement of literacy prohibits Enhancement of literacy enable 8.2 1D Symbologies 8.2.1 EAN 13 1. Enable or Disable EAN13 The user can enable and disable the EAN13 barcode reading function by reading the following programming barcodes. **Enable EAN13 Disable EAN13 2.
EAN8 Add-On Code Required ** EAN8 Add-On Code Not Required The user can enable and disable the configuration of the EAN8 add-on code by reading the following programming barcodes. Enable EAN8-2 Digit Add-On Code ** Disable EAN8-2 Digit Add-On Code Enable EAN8-5 Digit Add-On Code ** Disable EAN8-5 Digit Add-On Code 3.
Page 49
The user can enable and disable the forced output function of UPC-A add-on code by reading the following programming barcodes. UPC-A Add-On Code Required ** UPC-A Add-On Code Not Required The user can enable and disable the configuration of the UPC-A add-on code by reading the following programming barcodes.
** Enable Transmission of UPCA Parity Bits Disable Transmission of UPCA Parity Bits 8.2.4 UPC-E0 1. Enable or Disable UPC-E0 The user can scan and disable the UPC-E0 barcode reading function by reading the following programming barcodes. **Enable UPC-E0 Disable UPC-E0 2.
3.Check bit Output Function Enable and Disable ** Enable Transmission of UPC-E0 Parity Bits Disable Transmission of UPC-E0 Parity Bits 8.2.5 UPC-E1 1. Enable or Disable UPC-E1 The user can enable and disable the UPC-E1 barcode reading function by reading the following programming barcodes.
Enable UPC-E1-5 Digit Add-On Code ** Disable UPC-E1-5 Digit Add-On Code 3. Check bit Output Function Enable and Disable ** Enable Transmission of UPC-E1 Parity Bits Disable Transmission of UPC-E1 Parity Bits 8.2.6 Code128 1. Enable or Disable Code128 The user can enable and disable the Code128 barcode reading function by reading the following programming barcodes.
The user can turn on or off the Code128 barcode prefix (11) function by reading the following setting codes. Code128 Prefix (11)-On **Code128 Prefix (11)-Off 8.2.7 Code39 1. Enable or Disable Code39 The user can enable and disable the Code39 barcode reading function by reading the following programming barcodes.
Page 54
Output of Code39 Start Character **Disable Output of Code39 Stop Character Output of Code39 Stop Character **Disable Output of Code39 Stop Character 4. Code32 Mode Users can choose whether Code39 supports Code32 mode by reading the following programming barcodes. Support Code32 Mode ** Disable Support Code32 Mode Users can choose whether Code 32 outputs the prefix A by reading the following programming barcodes.
The user can set whether Code39 handles verification by reading the following setting code. Code 39 Handles Verification **Code 39 Does Not Handle Verification 8. Parity bit Output The user can set whether Code39 outputs check bits by reading the following setting codes. Code39 Outputs Parity Bits **Code39 Does Not Output Parity Bits 8.2.8 Code93...
Set the Maximum Length for Code93 to 32 **Set the Maximum Length for Code93 to 255 8.2.9 CodaBar 1. Enable or Disable CodaBar The user can enable and disable the CodaBar barcode reading function by reading the following programming barcodes. **Enable CodaBar Disable CodaBar 2.
Output of CodaBar Start/Stop Character **Disable Output of CodaBar Start/Stop Character 4. Verification Processing The user can set CodaBar check processing by reading the following setting codes. ** CodaBar Do Not Process Verification CodaBar Mod10 Check CodaBar Mod16 Check CodaBar Double Check 5.
Page 58
programming barcodes. Set the Minimum Length to 0 **Set the Minimum Length to 4 **Set the Maximum Length to 32 Set the Maximum Length to 255 3. Verify Format Setting The user can set whether Interleaved 2 of 5 processes verification by reading the following setting code. Interleaved 2 of 5 Verification Format Mod10 **Interleaved 2 of 5 Verification Format NONE 4.
Enable Industrial 25 **Disable Industrial 25 2. Set Length Range for Industrial 25 Users can set the minimum and maximum length of Industrial 25 by reading the following programming barcodes Set the Minimum Length to 0 **Set the Minimum Length to 4 **Set the Maximum Length to 32 Set the Maximum Length to 255 3.
8.2.12 Matrix 2 of 5 1. Enable or Disable Matrix 2 of 5 The user can enable and disable the Matrix 2 of 5 barcode reading function by reading the following programming barcodes. Enable Matrix 2 of 5 ** Disable Matrix 2 of 5 2.
Matrix 2 of 5 Outputs Parity Bits ** Matrix 2 of 5 Does Not Output Parity Bits 8.2.13 Code11 1. Enable or Disable Code11 The user can enable and disable the Code11 barcode reading function by reading the following programming barcodes. Enable Code11 **Disable Code11 2.
**Check Code11-1bit Check Code11-2bit 4. Parity Bit Output Setting The user can set whether Code11 outputs check bits by reading the following setting code. Code11 Outputs Parity Bits ** Code11 Does Not Output Parity Bits 8.2.14 MSI Plessey 1. Enable or Disable MSI Plessey Enable MSI Plessey **Disable MSI Plessey 2.
Single Mod10 ** Double Mod10 4. Parity Bit Output Setting The user can set whether MSI Plessey outputs check bits by reading the following setting code. MSI Plessey Outputs Parity Bits ** MSI Plessey Does Not Output Parity Bits 8.2.15 RSS-14 1.
programming barcodes. Enable RSS-Limited **Disable RSS-Limited 2. AI () output enable and disable The user can set whether RSS-Limited barcode AI () is output by reading the following setting codes. **RSS-Limited AI Output with Parentheses RSS-Limited AI Output Without Parentheses 8.2.17 RSS-Expanded 1.
**Set the Maximum Length to 32 Set the Maximum Length to 255 3. AI () output enable and disable The user can set whether RSS-Expanded barcode AI () is output by reading the following setting codes. **RSS-Expanded AI Output with Parentheses RSS-Expanded AI Output Without Parentheses 8.3 Operation of 2D Symbologies 8.3.1 QR Code...
Enable QR Mode1 ** Disable QR Mode1 3. QR Code prefixed (11) The user can turn on or off the e QR barcode prefix (11) function by reading the following setting codes. QR Prefix (11)-On **QR Prefix (11)-Off 8.3.2 Data Matrix (DM) The user can enable and disable the Data Matrix reading function by reading the following programming barcodes.
8.3.3 PDF417 The user can enable and disable the PDF417 barcode reading function by reading the following programming barcodes. **Enable PDF417 Disable PDF417 8.3.4 Mico QR The user can enable and disable the Mico QR barcode reading function by reading the following programming barcodes.
9. Save and Cancel 9.1 Save After reading the "Digit Barcodes", you need to read the programming barcode of "Save" to save the data. Save 9.2 Cancel When an error occurs in the scanned data, the following programming barcode can be scanned to cancel the current setting, also one bit of data which is previous scanned, and a string of data which is previous scanned.
10. Batch Setting When the reading device needs to make multiple setting, setting one by one may be complicated. The user can save all the information to be set into a QR code, and the device can complete multiple setting after reading the QR code.
Appendix B: Example of Parameter Settings ◆ Example 1: Modify the prefix to DATA 1. Query the character table to obtain the hexadecimal values corresponding to the four characters of "DATA": "44", "41", "54", "41" 2. Scan "Enter Setup"; (If it has been enabled, you can skip this step) 3.
Page 73
5. Read the programming barcode of "Save" 6. Read the programming barcode of "Tansmit the Start Data " ◆ Example 5: [Tansmit the End Data ] If the decoding information is "1234567890ABC", the first 10 bytes "1234567890" shall be output. 1.
4. Read the Digit Barcodess of "4" "A", "4", "1", "4", "9", "4", "C" in turns 5. Read the programming barcode of "Save" ◆ Example 8: Modify GS to replace the character with "D" 1. Query the character table to obtain the hexadecimal value corresponding to the "D" character: "44" 2.
Page 75
HID Leading Key Output Disable Scanning Module Parameter Default Scanning Module Manual Mode Trigger Mode Level Trigger Range: 100ms ~ 25500ms, Decode Session Timeout 5000ms Step length 100ms, Manual Mode 0: means Infinite Deep Sleep Timeout: 0~3276700ms Deep Sleep Step Size: 100ms Triggering Conditions Instruction Trigger 7E 00 08 01 00 02 01 AB CD...
Page 76
Delay time range: 100ms ~ 25500ms Timeout between Decodes Step size 100ms (Same Barcode) 0x00: infinite The more the parameter is, the less the Sensitivity Medium Sensitivity sensitivity is Range: 0 ~ 25500ms Image Stabilization Timeout Step size 100ms General Settings ON when Positioning Light Fill Light /...
Page 77
Enable and Invoicing Mode Local Invoicing Mode Data Editing Prefix Disable Suffix Disable CODE ID Disable Tail CR(0x0D) Date Character Interception Transmit all Data RF Information Disable Output Protocol Raw Data GS Character Replacement Disable Web address code recognition Enable Code Setting Inverse Video Disable...
Page 78
Parity Bit Output Enable UPC-A Read Enable Add-On Code Not Required 2 Digit Add-On Code Disable 5 Digit Add-On Code Disable UPC-A to EAN13 Disable Parity Bit Output Enable UPC-E0 Read Enable Add-On Code Not Required 2 Digit Add-On Code Disable 5 Digit Add-On Code Disable...
Page 79
Start Character Disable Stop Character Disable Code32 Disable Code32 prefix output Enable FullAsc Mode Disable Proces verification Parity bit output Disable Code 93 Read Enable Set the Minimum Length Set the Maximum Length CodaBar Read Enable Set the Minimum Length Set the Maximum Length Start /Stop Character Disable...
Page 80
Read Disable Set the Minimum Length Set the Maximum Length Verify Format None Parity bit output Disable Code11 Read Disable Set the Minimum Length Set the Maximum Length Verify Format 1bit Parity bit output Disable MSI Plessey Read Disable Set the Minimum Length Set the Maximum Length Verify Format Single Mod10...
Appendix G Batch Setting Code Content Parameter List Setting Code Function of Setting Code Remark Content Parameter If the Settings code is off, you need Enter Setup 00000000 to turn on the Settings code first TL-232 Serial Output 01000000 USB-HID 01000001 USB Virtual Serial Port Mode 01000002...
Page 89
Timeout Before HID Release-5ms 01050005 Timeout Before HID Release-10ms 0105000A Timeout After HID Release-1ms 01060001 Timeout After HID Release-2ms 01060002 For other durations, the last two parameters can be modified Timeout After HID Release-5ms 01060005 Timeout After HID Release-10ms 0106000A CapsLock-Off 01070000 CapsLock-On...
Page 90
Timeout Between Decodes-5000ms 02050032 Timeout between Decodes (Same Barcode)-OFF 02060000 The duration parameter setting must Timeout between Decodes first enable the timeout between (Same Barcode)-ON 02060001 Decodes Timeout between Decodes (Same Barcode)-Infinite Delay 02070000 Timeout between Decodes (Same Barcode)-500ms 02070005 Timeout between Decodes 0207000A (Same Barcode)-1000ms...
Page 91
Positioning Light - ON when Photographing 03010000 Positioning light -always ON when Photographing 03010003 Positioning Light - always ON 03010001 Positioning Light - always OFF 03010002 Deep Sleep-ON 02030000 Deep Sleep-OFF 02030001 Mute _ ON 04000000 Mute _ OFF 04000001 Passive Buzzer 04010005 Passive_Low Frequency...
Page 92
Data Output Encoding Format--UTF8 04050001 Data Output Encoding Format--Original Data 04050002 Data Output Encoding Format--UNICODE 04050003 Chinese output shielding-ON 04050100 Chinese output shielding-OFF 04050101 Keyboard-US. 04060000 Keyboard-Czech 04060001 Keyboard-French 04060002 Keyboard-Germany 04060003 Keyboard-Hungary 04060004 Keyboard-Italy 04060005 Keyboard-Japan 04060006 Keyboard-Spain 04060007 Keyboard-Turkey Q 04060008 Keyboard-Turkey F...
Page 94
Modify RSS-14 CODE ID 0503000E Modify Limitted RSS CODE ID 05030010 Modify Expanded RSS CODE ID 05030011 Modify QR CODE CODE ID 05030012 Modify DataMatrix CODE ID 05030013 Modify PDF417 CODE ID 05030014 Modify Mico QR CODE ID 05030015 Modify Chinese Sensible(HanXin) CODE ID 05030016 Tail OFF 05040000...
Page 95
Fast POS Mode 06000000 Serial Port & Full Codes ON 06000001 Enable All Symbologies 07000000 Disable All Symbologies 07000001 Enhancement of literacy prohibits 07000007 Enhancement of literacy enable 07000008 Enable Default Symbologies 07000002 Enable Transmit Check Digit 05090000 Disable Transmit Check Digit 05090001 Enable EAN13 07010000...
Page 97
Disable UPC-E1-2 Digit Add-On Code 07052100 Enable UPC-E1-5 Digit Add-On Code 07053000 Disable UPC-E1-5 Digit Add-On Code 07053100 Enable Transmission of UPC-E1 Parity Bits 07054000 Disable Transmission of UPC-E1 Parity Bits 07054100 Enable Code128 07060000 Disable Code128 07060100 Set the Minimum Length for Code128 to 0 07061000 Set the Minimum Length for Code128 to 4 07061004...
Page 98
Disable Support FullAsc Mode 07075100 Code 39 Handles Verification 07077000 Code 39 Does Not Handle Verification 07077100 Code39 Outputs Parity Bits 07078000 Code39 Does Not Output Parity Bits 07078100 Enable Code93 07080000 Disable Code93 07080100 Set the Minimum Length for Code93 to 0 07081000 Set the Minimum Length for Code93 to 4 07081004...
Page 99
Set the Minimum Length for Interleaved 2 of 5 to 4 070A1004 For other durations, the last two Set the Maximum Length for Interleaved 2 of 5 to 32 070A1120 parameters can be modified Set the Maximum Length for Interleaved 2 of 5 to 255 070A11FF Interleaved 2 of 5 Verification Format Mod10 070A2000...
Page 100
Disable Code11 070D0100 Set the Minimum Length for Code11 to 0 070D1000 Set the Minimum Length for Code11 to 4 070D1004 For other durations, the last two parameters can be modified Set the Maximum Length for Code11 to 32 070D1120 Set the Maximum Length for Code11 to 255 070D11FF Code11 Verification Format 1bit...
Page 101
Disable RSS-Expanded 070F2100 RSS-Expanded AI Output Without Parentheses 070F9000 RSS-Expanded AI Output with Parentheses 070F9100 Set the Minimum Length for RSS to 0 070F3000 Set the Minimum Length for RSS to 4 070F3004 For other durations, the last two parameters can be modified Set the Maximum Length for RSS to 32 070F3120 Set the Maximum Length for RSS to 255...
Need help?
Do you have a question about the HBCS-2D110W and is the answer not in the manual?
Questions and answers