5
Commissioning
→ OPERATING MODES
→ LOCKED
→ PDetection
→ SLUICE MODE
→ TPubOpenDelay
→ TSecOpenDelay
→ TLedInterval
→ TPubWaitIN
→ TSecWaitIN
→ TDelayIdle
→ TTimeDecision
→ MAINTENANCE
→ PArea
→ TLedIntervall
→ Override
→ CLEANING
→ TDuration
→ TWarningExit
→ PANIC
→ TPubOpenDelay
→ TSecOpenDelay
→ TRAFFIC LIGHTS
→ PTrafficeLEDIdle
→ LOCK-DOWN
→ PExitWay
→ DOOR LOCKING
→ Safety locking
22 / 30
OFF
Protection against confinement in the LOCKED operat-
ing mode:
ON: detection in the portal reopens the last opened door
OFF: doors close and lock (danger of confinement)
5 (ds)
Delay time to open the door "public side" in sluice mode
5 (ds)
Delay time to open the door "secure side" in sluice mode
5 (ds)
Traffic lights interval in sluice mode
40 (ds)
Time waiting for a person to go into the sluice from the
public side before the door closes again
40 (ds)
Time waiting for a person to go into the sluice form the
secure side before the door closes again
10 (ds)
Delay time to check is door is empty
10 (sec)
Timeout waiting for verification (this could be an external
selection, finger print, contact mat sensor etc.)
PUB
Select from which side maintenance can be done:
PUB = public side
SEC = secure side
10 (ds)
Traffic lights blinking interval during maintenance mode
OFF
Switch on maintenance mode via Service Display (in any
operating mode)
10 (min.)
Time allotted for cleaning mode
50 (ds)
Warning signal (buzzer or optional voice message), to
exit the door as the cleaning time has expired
5 (ds)
Delay time to open the door "public side" in panic mode
5 (ds)
Delay time to open the door "secure side" in panic mode
gn (green) Color of traffic lights when the security portal is empty:
gn = green
red = red
PUB
Select which door will open as exit way when the lock-
down button is pressed. First the opposite door will close
for security reason.
PUB = public side
SEC = secure side
OFF
Locking function that always locks the opposite door
when one door isn't closed.