Parameter Settings - Service Display - Record R 62 User Manual

Service display
Hide thumbs Also See for R 62:
Table of Contents

Advertisement

R62 SECUTEC Parameter
D = Wert wird beim Laden der Defaultparameter nicht zurückgestellt
Parameters
└►
Customer
└►
Customer
└►
Sensor
└►
PSensortype
└►
Operating Modes
└►
Locked Mode
└►
PDetection
└►
Sluice Mode
└►
TPubOpenDelay
└►
TSecOpenDelay
└►
TLedInterval
└►
TPubWaitIN
└►
TSecWaitIN
└►
TDelayIdle
└►
TTimeDecision
└►
Maintenance Mode
└►
PArea
└►
TLedIntervall
└►
Override
└►
Cleaning Mode
└►
TDuration
└►
TWarningExit
└►
Panic Mode
└►
TPubOpenDelay
└►
TSecOpenDelay
└►
Traffic Lights
└►
PTrafficLEDIdle
└►
Emergency Closing
└►
PExitWay
└►
Door Locking
└►
safety locking
└►
Alarming
└►
General
└►
PAutoReset
└►
TTechAlarmDelay
└►
TLedIntervall
└►
TMatAlarmDelay
└►
PEntranceFlash
└►
TPubOpenDelayTech
└►
TSecOpenDelayTech
└►
Buzzer
└►
TTechAlarm
└►
TOnTime
└►
Public Door
└►
TWrongPos
└►
TNotOpNotCl
└►
TForcedOpen
└►
Secure Door
└►
TWrongPos
└►
TNotOpNotCl
└► TForcedOpen
factory settings
0
2
OFF
ON
5
(ds)
5
(ds)
5
(ds)
40
(ds)
40
(ds)
10
(ds)
10
(sec)
PUB
SEC
(public)
(secure)
10
(ds)
OFF
ON
10
(min.)
50
(ds)
5
(ds)
5
(ds)
gn
red
(green)
PUB
SEC
(public)
(secure)
OFF
ON
OFF
ON
30
(sec)
1
(ds)
60
(sec)
0 ... 4
0
5
(ds)
5
(ds)
10
(min.)
5
(ds)
30
(sec)
10
(sec)
10
(ds)
30
(sec)
10
(sec)
10
(ds)
Description
parameter to select special customer functions: 0 = Standard, 1 = Toronto
parameter to select the Senssor type: 0 = no Sensor, 1 = contact mats,
2 = IEE 3D - Tailgating sensor, 3 = extern decision
Protection against confinement in the LOCKED operating mode.
ON: detection in the "portal" reopens the last opened door.
OFF: doors close and lock (danger of confinement).
set delay time to open the door "public side" in sluice mode
set delay time to open the door "secure side" in sluice mode
set time traffic lights interval in sluice mode
time waiting for a person to go into the sluice from the public side, before door closes
again
time waiting for a person to go into the sluice from the secure side, before door closes
again
delay time to check if door is empty
timeout waiting for verification (this could be an external decision, finger print, contact
mats, Sensor, etc.)
selection from which side maintenance can be done
set time for traffic lights blinking interval during maintenance mode
set maintenance mode via service display (in any operating mode)
time how long the cleaning mode can be performed
warning signal (buzzer or optional voice message) to leave the door because time for
cleaning mode elapsed
door hold open time "public side" in panic mode
door hold open time "secure side" in panic mode
color of traffic lights when the security portal is empty
Selection which door will open as exit way when the emergency button is pressed. First
the opposite door will be closed to be secure.
Locking function that always locks the opposite door when one door isn't closed
selection to switch automatic reset "on" or "off" when alarm disappeared
delay time to activate alarming in case of an technical alarm
set time for traffic lights blinking interval during alarm
delay time if there is an Alarm from the door drives or a sensor faulty
The entrance flashs indicate type of alarms. 0 = all alarms; 1 = intrusion; 2 = Tailgating;
3 = technical alarm; 4 = sabotage
door hold open time public door in case of technical alarm
door hold open time secure door in case of technical alarm
time between repeating signaling with the buzzer when technical alarm is still present
time while the buzzer is on
delay time alarming public door does not open or close
delay time alarming while public door is between open and closed position
delay time for alarming when the public door was closed and has no longer an open
command of the PLC
delay time alarming secure door does not open or close
delay time alarming while secure door is between open and closed position
delay time for alarming when the secure door was closed and has no longer an open
command of the PLC
≥ V0.13.0

Advertisement

Table of Contents
loading

Table of Contents